DIMENSIONS

Model

Q max. 

(l/min)

max. 

(m)

A 1 ~

230V

C –

µF P1 

(kW)

IP

Eff.

(%)

dBa 

± 1

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

(mm PVC)

(mm PVC)

kg

Whisper 500W

180

12.2

2

12

0.45

55

35

<70

475

115

301

108

212

312

50

50

7.4

Whisper 750W

230

13.5

2.9

12

0.65

55

42

<70

475

115

301

108

212

312

50

50

7.7

Whisper 1000W

290

14

3.8

12

0.85

55

50

<70

475

115

301

108

212

312

50

50

8.5

Typhoon C75M

340

15

5.5

16

1.2

55

47

<70

532

170

345

159

238

330

50

40

10.7

Typhoon C100M 380

16.5

6.2

16

1.5

55

48

<70

532

170

345

159

238

330

50

40

11.4

Typhoon C150M 430

18.5

7.1

25

1.6

55

55

<80

560

170

345

159

238

330

50

40

13.5

Typhoon T150M 500

19

8.5

25

1.9

55

61

71

613

200

397

231

429

270

50

50

18

Typhoon T200M 550

19.5

9.7

30

2.2

55

64

72

613

200

397

231

429

270

50

50

20.7

Typhoon T300M 650

22.5

12.5

60

2.6

55

63

73

613

200

397

231

429

270

50

50

20.6

V/Hz esp.: See pump nameplate   Liquid Temperature: 4°C ~ 35°C  Storage temperature: -10°C~ +50°C  Relative Air Humidity: 95% Max.  Motor class: I
H max. refers to the maximum total head in metres.

Possible faults, their causes and solutions

1. Pump does not prime    2. Pump supplies scant flow    3. Pump noisy     

4. Pump does not start    5. Motor makes sound but does not start

1

2

3

4

5

Problem

Solution

X

X

Air entry through suction line

Verify condition of connectors and gaskets of suction linw

X

Inadequate airtightness of filter cover

Clean the filter cover and verify condition of rubber gasket

X

X

Motor turning direction reversed

Reverse 2 phases of the supply

X

Defective mechanical seal

Change mechanical seal

X

X

Excessive suction height

Set pump at a suitable level

X

X

X

Incorrect voltage

Verify the voltage specified on the nameplate and that of the mains

X

No water in prefilter

Fill prefilter with water

X

Suctioning out of water

Set suction in correct position

X

Filter clogged

Clean filter

X

X

Diameter of suction line smaller than required Correctly dimension suction line

X

Discharge clogged

Inspect filter and discharge line

X

Incorrect pump attached

Attach pump correctly

X

Foreign body in pump

Clean pump and inspect its filter

X

Thermal relay tripped

Reset thermal relay

X

Lack of power

Reset the fuses

X

Motor blocked

Remove the motor and call the technical service

If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person in order to avoid a hazard.

Содержание WHISPER Series

Страница 1: ...s may cause serious bodily injury and or property damage The installation of this product should be carried out by a person knowledgable in swimming pool plumbing requirements following the installation instructions provided in this manual Typhoon Whisper WHISPER Series TYPHOON C T Series Swimming Pool Pumps Installation and Operating Instructions ...

Страница 2: ...of these installation and operating instructions please contact your Davey dealer or the appropriate Davey office as listed on the back of this document The Davey Whisper and Tyhoon pool pumps have been designed to circulate swimming pool and spa water in conditions set out in the Australian Standard for swimming pool water quality AS 3633 or equivalent They should not be used for any other purpos...

Страница 3: ...lt consequences for which we decline all responsibility Installation The installation of our electric pumps is only permitted in swimming pools or ponds that meet DIN standards VDE 0100 part 702 11 82 In case of doubt inquire with an expert The pump should be installed as near as possible to water level in horizontal position in order to obtain a minimum suction path and reduce head losses It is n...

Страница 4: ...ld be structured with a slight slant to prevent the formation of siphons Electrical connection IMPORTANT INFORMATION Your Davey pump is Double Insulated to Water Circuit If equipotential bonding structure is required then a Equipotential Bonding Point is provided Please refer to your local statutes and regulations for AS NZ 3000 Wiring standards The electrical installation should have a multiple s...

Страница 5: ...nd their possible solutions provided in this manual NEVER RUN THE PUMP DRY Starting Open all the gate valves and put the motor under voltage Wait a reasonable time to allow self priming Verify the breakaway current and suitable adjust the thermal relay Maintenance WARNING Ensure that the pump is switched off from the supply mains before removing the cover Pumps are not to be plugged permanently to...

Страница 6: ...p it contains no toxic or contaminating materials The principal components are duly identified for selective breaking If the supply cord is damaged it must be replaced by the manufacturer or it s service agent or a similarly qualified person in order to avoid a hazard SINGLE PHASE SUPPLY Fig 1 ...

Страница 7: ...prime 2 Pump supplies scant flow 3 Pump noisy 4 Pump does not start 5 Motor makes sound but does not start 1 2 3 4 5 Problem Solution X X Air entry through suction line Verify condition of connectors and gaskets of suction linw X Inadequate airtightness of filter cover Clean the filter cover and verify condition of rubber gasket X X Motor turning direction reversed Reverse 2 phases of the supply X...

Страница 8: ...ty The warranty claim will be assessed by Davey on the basis of their product knowledge and reasonable judgement and will be accepted if a relevant defect is found the warranty claim is made during the relevant warranty period and none of the excluded conditions listed above apply The customer will be notified of the warranty decision in writing and if found to be invalid the customer must organis...

Отзывы: