13
3URJUDPPLQJ%RRVW&\FOH7LPHYLD'LJLWDO,QSXWV
Boost cycle time can be changed via digital input on the RJ45 Aux connector.
To change cycle time connect digital inputs 1, 2 and 3 to 24V. The periodic
agitation time will cycle to the next setting. The dial LED will flash amber the
number of times corresponding to the updated setting.
Setting
Time to Run at 100% per hour of operation
1 (default)
0
2
5 minutes
3
10 minutes
4
15 minutes
Analogue Control Input
Speed control can also be achieved by connecting a 0-10V signal at the input
on pin 4 (ground at pin 5). As soon as a signal above 0V is registered, this
input will take priority over dial settings.
Pin4 (Blue)
Pin5 (Blue/White)
+ 0~ 10 V DC Signal Output
of controlling equipment
DC Ground
Controlling Equipment
To RJ45 Socket of VSD Pump
RS485
RS485 inputs are reserved for Davey service connection and software updates.
3URJUDPPLQJ%RRVW&\FOLQJ7LPHYLD',36ZLWFKHV
As an alternative to using digital inputs, boost cycle time can be changed
via internal PCB board with DIP switches. (Please contact your nearest
Davey Dealer or Davey for advice).