Operating your Suction Pool Cleaner

Before installing or purchasing a pool cleaner for use with your ProMaster 

pool pump, it is important to know the minimum flow rates required for it to 

operate effectively.

To operate a suction pool cleaner with your  

ProMaster Premium VSD400 pump:

1. Activate the High Flow setting (10) and allow the pump to fully prime by 

running for around 2 minutes. You will know the pump is primed when you 

can see a strong flow of water through the clear leaf basket lid.

2. When all air is expelled from the leaf basket, connect the pool cleaner 

hose firmly into the skimmer plate or dedicated wall suction.

3. Select the speed setting that enables best performance from your suction 

pool cleaner. Speed 3 to 7 should be ample for most cleaners, however if 

the cleaner requires better performance, select speeds 7 to 10. A Davey 

PoolSweepa suction pool cleaner is recommended to run between speeds 

2 to 3.

4. The cleaner should only be connected for as long as is required to clean 

the surface of your pool. When cleaning is complete, disconnect the 

cleaner and remove the skimmer plate from the skimmer box.

127(7RJHWRSWLPXPHQHUJ\HI¿FLHQF\IURP\RXU3UR0DVWHU

 

DO NOT keep 

the suction pool cleaner connected when cleaning is not required.

5. Reactivate the most efficient speed setting for daily filtration. Speeds 1 to 4 

is recommended.

0DLQWHQDQFH(PSW\LQJWKH6WUDLQHU%DVNHW

The strainer basket should be inspected frequently through the transparent 

lid and emptied when a build up of rubbish is evident. The directions below 

should be followed.
1. Switch off pump.
2. Unscrew the strainer basket lid anti-clockwise and remove.
3. Remove the strainer basket by lifting upwards from its housing.
4. Empty the trapped refuse from the basket. Hose out with water if necessary.

NOTE: NEVER knock the plastic basket on a hard surface as it will cause damage.

Содержание PM400PV

Страница 1: ...ury and or property damage Please pass these instructions on to the operator of this equipment ProMaster This pump requires professional expertise for installation and maintenance The installation of...

Страница 2: ...ghly water tested against a number of flow pressure voltage current and mechanical performance parameters Davey s advanced pump manufacturing technology provides reliable and efficient pumping perform...

Страница 3: ...is also NORMAL The lower system pressure is simply a result of the lower speed and flow rate produced by the pump While running at the lower speed settings you will also notice a significant reduction...

Страница 4: ...z 50 60 Motor Input Power W hp Speed Setting 1 120W 0 16 hp Speed Setting 5 660W 0 89 hp Speed Setting 10 1630W 2 2hp Backwash Setting Variable Operating Limits Max Water temperature 40 C Max Ambient...

Страница 5: ...nufacturer with genuine Davey spares This ProMaster pool pump incorporates motor overload detection designed to protect the motor from overheating If the motor gets too hot during operation its operat...

Страница 6: ...connected to the inlet connection on the swimming pool filter usually at the filter control valve DUUHO XQLRQV QHHG WR EH KDQG WLJKWHQHG 1R VHDODQW JOXHV RU silicones are required Prior to using this...

Страница 7: ...n floor cleaning systems Solar pool heating Guidelines for Recommended Pump Operating Hours Australian Standards AS3633 Private swimming pools water quality states that The minimum turnover rate shall...

Страница 8: ...gs for programming time for full speed Boost cycling and warnings Solid Green Normal Dial Operation Slow Flashing Green Backwash Fast Flashing Green Boost Cycling AUX External Control Solid Amber Spee...

Страница 9: ...between a low and high speed to help air rate and agitate the filter media for a more effective clean Reduces wasted water during the backwash cycling process Full variable frequency drive with user...

Страница 10: ...ousing from rear It is recommended to keep the cable length between the pump and external pool controller or heater as short as possible There are two major pin configurations as shown below Figure 2...

Страница 11: ...e for the digital inputs DO NOT power external equipment from this supply rail Digital Control Inputs The 3 digital inputs allow for overriding the dial speed setting To set one of these inputs either...

Страница 12: ...ntrolling Equipment To RJ45 Socket of VSD Pump If the controlling equipment does not have 18 24VDC voltage output as above and it has 24VAC 230VAC 12AC or 12 DC etc signal output a suitable relay the...

Страница 13: ...trol Input Speed control can also be achieved by connecting a 0 10V signal at the input on pin 4 ground at pin 5 As soon as a signal above 0V is registered this input will take priority over dial sett...

Страница 14: ...of operation 0 5 10 15 20 25 0 50 100 150 200 250 300 350 400 450 Total Head m ProMaster PM400PV Performance Dial position No 10 Dial position No 9 Dial position No 8 Dial position No 7 Dial position...

Страница 15: ...ds 7 to 10 A Davey PoolSweepa suction pool cleaner is recommended to run between speeds 2 to 3 4 The cleaner should only be connected for as long as is required to clean the surface of your pool When...

Страница 16: ...lubricated with Hydra slip or equivalent products Failure to undertake regular maintenance may cause damage not covered by warranty Power supply to this pump needs to be through an RCD having a rated...

Страница 17: ...The pump is not able to get water from the pool Check that the valves to the pump are fully open and that the pool water level is up to the skimmer box 6 Blockage in the piping or pump Remove the stra...

Страница 18: ...e the o rings 4 Move the pipework with the barrel unions attached until the pump can be pulled clear NOTE When making any enquiries about your ProMasterbe certain to quote the model number from the na...

Страница 19: ...s are free of leaves and debris at least once a week f Remove obstructions and combustibles from around the pump motor g Make sure all wiring connections are clean and that all wiring and electrical e...

Страница 20: ...ver normal wear or tear replacement of product consumables i e mechanical seals bearings or capacitors loss or damage resulting from misuse or negligent handling improper use for which the product was...