22
Once the salt concentration is corrected, the
LOW SALT CUT-OUT ALARM
must be reset by pushing the
manual ON/OFF
button (except for models where the ON/OFF button is deactivated). Alternatively,
the EcoSalt2 will conduct a system check automatically when powered up the next time (if operating via a
separate power supply). Upon start-up if the EcoSalt2 registers a salt concentration within range (refer to
recommended salt range section in the manual), the EcoSalt2 will return to normal operation.
LOW SALT CUT-OUT ALARM
is triggered at the following (approximate) salt concentrations:
(If salt levels are in range and water temperature is above 15°C (59°F), your cell may need to be cleaned.)
EcoSalt2 model
Low salt cut-out alarm (approx. salt concentration)
DES2-15EL, DES2-25EL
DES2-15USL, DES2-25USL
1,000ppm (mg/L)
DES2-15E, DES2-25E, DES2-35E
DES2-15US, DES2-25US, DES2-35US
2,000ppm (mg/L)
ADD SALT ALARM AND LOW FLOW ALARM
Should the EcoSalt2 register low flow and a salt concentration below its minimum (refer to recommended
salt range section in the manual), the EcoSalt2 will alarm. The display will toggle between the
ADD SALT
ALARM
and the
LOW FLOW ALARM
. In
LOW FLOW ALARM
, the EcoSalt2 will not produce chlorine. As
shown previously once faults are rectified, normal operation will resume.
OVERRIDING LANGUAGE SETTING
70% – 09:35 AM
CHLORINE OUTPUT
> From the
HOME
screen, press and hold
menu/setting select
for 3 seconds.
SETTINGS
1. CLOCK
> Press the
menu up/down
buttons to scroll down to
LANGUAGE
;
ENGLISH