background image

7

Trouble Shooting Check List

a)  MOTOR RUNS WHEN SWITCHED ON BUT DOES NOT PUMP.

  1.  Suction line and pump body not filled with water.

  2.  Air leaks in suction lines or suction pipe not under water.

  3.  Air trapped in suction lines (also possible with flooded suction due to 

uneven rise in piping; eliminate humps and hollows).

  4.  No water at source or water level too low.

  5.  Valve on suction lines closed.

b)  PUMP SWITCHES ON AND OFF FREQUENTLY (CYCLING) - Pressure

  Pumps Only

  1.  Check that tank air pressure is correct - see above.

  2.  Leaking taps, float valves etc. check plumbing.

  3.  Leaking check valve/foot valve.

c)  MOTOR DOESN’T START WHEN SWITCHED ON.

  1.  Power not connected.

  2.  Supply voltage too low.

  3.  “Over temperature” cut-out tripped.*

  4.  Motor not free to turn eg. a jammed impeller.

  5.  Internal motor fault.

*NOTE: For protection, the Davey pump motor is fitted with an 

automatic “over temperature” cut-out.  Constant tripping of this 

overload device indicates a problem eg. low voltage at pump, 

excessive temperature (above 45

o

C) in pump enclosure.

Care should also be taken when servicing or disassembling pump 

to avoid possible injury from hot pressurised water.  Unplug 

pump, relieve pressure by opening a tap on the discharge side 

of the pump and allow any hot water in the pump to cool before 

attempting to dismantle.

During servicing, use only approved, non-petrochemical based 

oring and gasket lubrication.  If unsure, consult your Davey 

Dealer for advice.

WARNING: When servicing or attending pump, always ensure 

power is switched off and lead unplugged.  Electrical connections 

should be serviced only by qualified persons.

WARNING: Do not use hydrocarbon based or hydrocarbon 

propelledsprays around the electrical components of this pump.

In accordance with AS/NZS 60335.2.41 we are obliged to inform 

you that this pump is not to be used by children or infirm persons 

and must not be used as a toy by children.

Содержание E1P Series

Страница 1: ...3P XJ50P XJ70P XJ90P Pressure Pumps XJ50 XJ70 XJ90 Electric Pumps Please pass these instructions on to the operator of this equipment NOTE Prior to installation remove the inlet and outlet pipe transp...

Страница 2: ...ot covered by the guarantee Your Dynajet XJ pump is designed to handle clean water It should not be used for any other purpose without specific referral to Davey The use of the pump to handle flammabl...

Страница 3: ...w when pumping longer distances Power Connection Connect lead to power supply designated on pump label do not use long extension leads as they cause substantial voltage drop poor pump performance and...

Страница 4: ...e the hot water service Failure to install this non return valve may result in pump damage Such damage is not covered by guarantee Connection of Mains Scheme or Town Water Supply to either Suction or...

Страница 5: ...K VALVE AT THE PUMP OR AT THE TOP OF THE WELL DO NOT RUN THE PUMP WITHOUT WATER NOTE Be certain to select the spear point to suit the well conditions and regulate the flow rate from the pump according...

Страница 6: ...r available to the pump Never operate your Davey Dynajet pump for more than a few seconds without discharge flow Maintenance The only regular attention your new pressure system requires is to check th...

Страница 7: ...h an automatic over temperature cut out Constant tripping of this overload device indicates a problem eg low voltage at pump excessive temperature above 45o C in pump enclosure Care should also be tak...

Страница 8: ...gned or advertised failure to properly follow the provided installation and operating instructions failure to carry out maintenance corrosive or abrasive water or other liquid lightning or high voltag...

Отзывы: