background image

5

Connection to your Water Source

BELOW GROUND WATER SOURCES

Whenever the installation position of the pump is higher than 1m (3.3ft) above the 

lowest water level, a foot valve must be used on the end of the suction pipe as 

illustrated in (C) below.  Ensure that the foot valve is at least 

1

/

2

 metre below mini-

mum water level.

SPEAR POINT INSTALLATIONS

When a Dynajet

®

 is installed on a spear or well point, a check valve must be fitted 

immediately on top of the spear point itself, as shown in (D) above.  

DO NOT IN-

STALL THE CHECK VALVE AT THE PUMP OR AT THE TOP OF THE WELL. DO 

NOT RUN THE PUMP WITHOUT WATER.

NOTE:  Be certain to select the spear point to suit the well conditions and 

regulate the flow rate from the pump accordingly.

SPEAR SIZE 

MESH 

APPROX. MAX. CAPACITY OF SPEAR 

POINT

1

1

/

4

” (32mm) 

60 

15 - 23 1/min or 200 - 300 gal/hr

1

1

/

2

” (38mm) 

60 

23 - 38 1/min or 300 - 500 gal/hr

2” (50mm) 

60 

38 - 75 1/min or 500 - 1000 gal/hr

Spear point flow capacities vary considerably. Check with the 

supplier to ensure the pump and spear point are correctly matched.

Priming and Operation

1.  Fill pump and suction line (on flooded 

suction, simply open gate valve 

to pump). When full, fit Supercell 

Pressure Tank or Priming Plug as 

applicable.

2. Ensure outlet nearest to pump is 

open.

Содержание E1P Series

Страница 1: ...3P XJ50P XJ70P XJ90P Pressure Pumps XJ50 XJ70 XJ90 Electric Pumps Please pass these instructions on to the operator of this equipment NOTE Prior to installation remove the inlet and outlet pipe transp...

Страница 2: ...ot covered by the guarantee Your Dynajet XJ pump is designed to handle clean water It should not be used for any other purpose without specific referral to Davey The use of the pump to handle flammabl...

Страница 3: ...w when pumping longer distances Power Connection Connect lead to power supply designated on pump label do not use long extension leads as they cause substantial voltage drop poor pump performance and...

Страница 4: ...e the hot water service Failure to install this non return valve may result in pump damage Such damage is not covered by guarantee Connection of Mains Scheme or Town Water Supply to either Suction or...

Страница 5: ...K VALVE AT THE PUMP OR AT THE TOP OF THE WELL DO NOT RUN THE PUMP WITHOUT WATER NOTE Be certain to select the spear point to suit the well conditions and regulate the flow rate from the pump according...

Страница 6: ...r available to the pump Never operate your Davey Dynajet pump for more than a few seconds without discharge flow Maintenance The only regular attention your new pressure system requires is to check th...

Страница 7: ...h an automatic over temperature cut out Constant tripping of this overload device indicates a problem eg low voltage at pump excessive temperature above 45o C in pump enclosure Care should also be tak...

Страница 8: ...gned or advertised failure to properly follow the provided installation and operating instructions failure to carry out maintenance corrosive or abrasive water or other liquid lightning or high voltag...

Отзывы: