OPERATION OF YOUR AquaReviva SALT WATER SANITISER
Cell Output
is expressed as a percentage. Set the system control to the percentage output required and the
XQLWZLOODXWRPDWLFDOO\DGMXVWWKHFHOORXWSXWWRWKHVHWOHYHO7KH8QLWLV¿WWHGZLWKDQHOHFWURQLFFRQWURODQG
warning system. This regulates the output of the Unit to the preset maximum and changes cell polarity as
indicated by POLARITY LEDs A&B. These LEDs will alternate over a number of hours or days depending on
how the unit is set to operate. The warning system consists of one
Operation LED
which will glow Green to
indicate normal operation or RED to indicate possible faults with the Unit or damaging operating conditions.
CONTROL PANEL LAYOUT
SELECTOR SWITCH
POLARITY
STATUS
FUSE 3A
A
B
P/N: 15777
0%
100%
1
2
3
4
5
6
7
8
Clock
Timer 1 - ON
Timer 1 - OFF
Timer 2 - ON
Timer 2 - OFF
Automatic
Manual - ON
OFF
6
8:00
AM
Once the TDS level in the pool is correct the unit may be switched on.
1RWH2QFHWKHXQLWVWDUWVWKHUHLVDVKRUWWLPHGHOD\XQWLOWKHFHOORSHUDWHVWRHQVXUHWKH¿OWUDWLRQV\VWHP
is primed with water.
At this point the Operation LED should be Green; if red refer below. Note: Polarity LED may be either A or B
whichever is on or brightest.
The RED Operation LED will indicate a number of different possible problem situations:
Possible Problem
Action
TDS Level Below Minimum
$GG3RRO6DOWDWWKHUHTXLUHGTXDQWLWLHVVSHFL¿HGE\\RXU
water testing agent
&HOOLV&DOFL¿HG
Clean Cell
Water temperature very cold
Add Salt to compensate for cold water
7KHUHLVDSUREOHPZLWKZDWHUÀRZ
Check pump / pipes for blockage or damage.
&KHFNWKDWÀRZVZLWFKLVFRQQHFWHGSURSHUO\DQGLQWKH
right direction.
SANITISER
OUTPUT DIAL
POLARITY
INDICATOR
LEDs
OPERATION
LED
FUSE HOLDER
AND FUSE
TIMER DISPLAY &
SETTINGS BUTTONS
OPERATION
SELECTOR SWITCH
403165_AquaReviva_I&OI.indd 10