background image

16

DAY TO DAY OPERATION

Four Prime rules must be observed if your unit is to give the best possible service:

1. STABILISER

The importance of pool stabiliser cannot be over – emphasised. It is essential in helping retain chlorine 

in your pool. Chlorine is rapidly dissipated by sunlight and the use of stabiliser will reduce this dissipation 

substantially. Without stabiliser, it may be necessary to run the Unit for up to three times as long!
Stabiliser should be added at the rate of 500 grams for every 10,000 litres of water. Stabiliser should be 

maintained at a level of 30 – 50 ppm. Before adding more stabiliser, have your pool water analysed at your 

pool shop to ensure that you do not add too much. 

(FOR OUTDOOR POOLS ONLY, INDOOR DO NOT 

REQUIRE STABILISER)

2. pH AND TOTAL ALKALINITY

A correct pH level must be maintained to prevent problems such as black spot, staining, cloudy water, etc.  

An incorrect pH level can damage the pool. Correct pH levels are as follows; Fibreglass – 7.2 to 7.4 

Concrete & tiled – 7.4 to 7.6 If you allow the pH level to rise to 8.0 or above, the chlorine required could be 

as much as three times the normal amount.
Total Alkalinity should not be confused with pH, although the two are closely related. Total Alkalinity 

determines the speed and ease of pH change. The ideal range is 80 – 150 ppm, or refer to your pool 

professional.
You should use a test kit which includes a test for Total Alkalinity. Low Total Alkalinity can cause unstable  

pH levels – i.e. An inability to keep the pH constant may cause staining, etching and corrosion of metals. 

High Total Alkalinity will cause constantly high pH levels.

3. TDS LEVELS

WARNING: Some people recommend that you put salt directly in the skimmer 

box. This is a very poor practice as it allows very high concentrations of salt 

WREHSDVVHGWKURXJK\RXU¿OWUDWLRQDQGRWKHUSRROHTXLSPHQW

6DOWLVWKHHVVHQWLDOHOHPHQWE\ZKLFK\RXU8QLWRSHUDWHV,QVXI¿FLHQW6DOWZLOOGDPDJH\RXU&HOO

RECOMMENDED TDS LEVEL RANGE: 4,000 - 6,000ppm

WARNING: Do not add Hydrogen Peroxide to pool water or through 

swimming pool hydraulic or sanitiser system. Use of Hydrogen Peroxide 

will void warranty on Davey products.

Salt is NOT used up in the sanitisation process or by evaporation. It is only lost through backwashing, 

VSODVKRXWRYHUÀRZRUE\OHDNDJHIURPWKHSRRORUSHDY\UDLQFDQGLOXWHWKH7'6OHYHOVLQ\RXU

pool; therefore TDS levels should be checked during these events.

Low TDS levels will destroy the coating on the Anode plates and will void all Warranty.

7KH$TXD5HYLYDKDVDEXLOWLQZDUQLQJLQGLFDWRUWRPLQLPLVHGDPDJHUHVXOWLQJIURPLQVXI¿FLHQW7'6OHYHOV

however, the ultimate responsibility is on the owner to ensure adequate TDS levels are maintained all year round.

4. RUNNING TIMES

These instructions cover AquaReviva for residential use only.
If you run your Sanitiser for 24 hours a day, or for long periods, the Cell life will be greatly reduced. It is important that 

the correct model AquaReviva has been installed on your pool. Many models are available from Davey to cope with 

small courtyard pools up to commercial applications. (Consult your local AquaReviva Dealer for more information).

Note: The AquaReviva guarantee does not apply to commercial or semi-commercial installations, i.e. where the 

system runs more than an average of 8 hours per day over the year. Guarantee on commercial and semi-commercial 

installations is 12 months only on both power supply and cells.

403165_AquaReviva_I&OI.indd   16

4/7/17   9:18 am

Содержание AquaReviva DAR20C

Страница 1: ...geable in swimming pool plumbing requirements following the installation instructions provided in this manual WARNING Failure to follow these instructions and comply with all applicable codes may cause serious bodily injury and or property damage AquaReviva Rainbow Pool Products PO Box 2388 Mansfield Qld 4122 Telephone STD 61 7 3849 5385 Facsimile STD 61 7 3849 5384 Email info rainbowpoolproducts ...

Страница 2: ...l the cell with water during the chlorination process Periodically check the paddle of the safety flow switch to ensure it is free to move back and forth Always check Davey s website davey com au for the latest versions of Installation Operation Instructions that support these products IMPORTANT INSTRUCTIONS FOR USE Diagram A CORRECT OPERATION WITH PUMP RUNNING Flow switch ON 9 Flow switch OFF Dia...

Страница 3: ...LY 7 PRE START UP PROCEDURE 8 OPERATION OF YOUR AquaReviva SYSTEM 10 CONTROL PANEL LAYOUT 10 AquaReviva SPECIAL FEATURES 11 AUTOMATIC TIME CLOCK OPERATION 12 MAINTENANCE OF POWER SUPPLY 14 MAINTENANCE OF THE IN LINE ELECTROLYTIC CELL 14 DAY TO DAY OPERATION 16 CHLORINE PRODUCTION 17 GENERAL INFORMATION 18 TROUBLE SHOOTING 19 Packing List Included with your AquaReviva System are the following items...

Страница 4: ...ible condition regular monitoring of the electrolytic cell is recommended The Cell is the clear plastic housing containing the plates During the sanitisation process a white powdery Calcium scale may naturally build up on the titanium plates in the cell Monitor the cell to prevent excessive scale build up Excessive scale EXLOG XS ZLOO FDXVH GDPDJH WR RXU FHOO DQG GUDPDWLFDOO UHGXFH LWV HI FLHQF DQ...

Страница 5: ... FILTER ACCESSORIES IN LINE CELL FLOW SWITCH POWER SUPPLY 240V Two self tapping screws and wall plugs have been provided for fast and simple installation 8VH D PP PDVRQU GULOO ELW ZKHQ WWLQJ 3RZHU 6XSSO WR D EULFN RU FRQFUHWH ZDOO KHQ PRXQWLQJ WR D SRVW GULOO SLORW KROHV DQG W VFUHZV SURYLGHG 2QFH VFUHZV DUH LQ SRVLWLRQ VLPSO KDQJ 6DQLWLVHU YLD EUDFNHW RQ back of Unit IMPORTANT This diagram is int...

Страница 6: ...XD5HYLYD HOO LV VXSSOLHG ZLWK D SDGGOH W SH ÀRZ VZLWFK which is to be installed on the Cell as shown in the diagram on page 6 03257 17 7KH ÀRZ VZLWFK PXVW EH PRXQWHG ZLWK WKH KLJKOLJKWHG DUURZ RQ WRS RI WKH VZLWFK SRLQWLQJ LQ WKH GLUHFWLRQ RI ÀRZ CONNECTING THE FLOW SWITCH TO THE POWER SUPPLY RLQ WKH FRQQHFWRU RQ WKH ÀRZ VZLWFK DQG WKH FRQQHFWRU RQ WKH FHOO FDEOH WRJHWKHU 7KH ZLOO FOLS WRJHWKHU CO...

Страница 7: ...6 12 5 250 13 8 276 15 0 300 16 3 326 17 5 350 6000 0 6 7 3 146 8 8 176 10 3 206 11 8 236 13 3 266 14 8 296 16 3 326 17 8 356 19 3 386 20 8 416 STORAGE AND SAFETY 1 Store in a dry covered place away from direct sunlight for longer bag life 2 Always use the entire bag content of Salt once opened Do not keep open bags of Pool Salt as it is sensitive to moisture in the air 3 Care should be taken to a...

Страница 8: ...r mineral pool water stays soft silky and crystal clear After adding Davey EcoMineral Salts to your pool the water may temporarily have discolouration and form clusters of foam on the surface This is completely normal and is part of the mineralisation stage and transformation process This may last for 24 hours KRZHYHU DIWHU WKLV WLPH RXU SRRO ZLOO UHWXUQ WR QRUPDO DQG EHFRPH FU VWDO FOHDU DQG FOHD...

Страница 9: ...Timer 1 ON Timer 1 OFF Timer 2 ON Timer 2 OFF Automatic Manual ON OFF 6 8 00AM Once the TDS level in the pool is correct the unit may be switched on 1RWH 2QFH WKH XQLW VWDUWV WKHUH LV D VKRUW WLPH GHOD XQWLO WKH FHOO RSHUDWHV WR HQVXUH WKH OWUDWLRQ V VWHP is primed with water At this point the Operation LED should be Green if red refer below Note Polarity LED may be either A or B whichever is on o...

Страница 10: ...ow Salinity Indicator As the TDS level in the pool decreases the wear on the Cell increases Although Salt and Activator is not consumed in the sanitisation process it is lost through splashing backwashing and on bathers as they leave the pool The TDS level is also reduced by rain which causes dilution As the TDS level in the pool falls toward the minimum TDS the Operation LED will turn RED At this...

Страница 11: ...WFK remains at this position Use the up and down buttons to reach the desired times Hold the buttons down for fast increments Set Timer 1 ON 2 SET THE START TIME FOR THE FIRST RUN TIME SEQUENCE Select the Timer 1 ON position on the selector switch A number 2 will appear at the left of the screen This time factory pre set to 6am Proceed as per a in the Set Clock instruction to change time To disabl...

Страница 12: ...ion to change time Automatic ON 6 FILTRATION SYSTEM SWITCHES ON AND OFF AUTOMATICALLY ACCORDING TO YOUR SET TIMES Select the Automatic ON position on the selector switch A number 6 will appear on the left of the screen Manual ON 7 OVER RIDES THE AUTOMATIC TIME CLOCK SETTINGS SWITCHES FILTRATION SYSTEM ON Select the Manual ON position on the selector switch A number 7 will appear on the left of the...

Страница 13: ... an extended period Calcium in the plaster surfaces of a concrete pool Because these conditions vary so much check the Cell at least weekly to begin with to see when either scale or a blue green soapy substance appears on the plates You will then be able to determine the cleaning cycle necessary for your pool more frequent cleaning may be required in summer The intervals between cleaning could get...

Страница 14: ...e scale is being dissolved from the plates the solution will foam when this foaming action has stopped the Cell is clean and the solution can be returned to the container for future use or discarded appropriately NOTE do not leave the acid solution in the Cell for more than hour 7 5LQVH WKH HOO RXW ZLWK FOHDQ WDS ZDWHU E OOLQJ DQG GUDLQLQJ D FRXSOH RI WLPHV FKHFN WKDW DOO WKH VFDOH deposits have b...

Страница 15: ...els 3 TDS LEVELS WARNING Some people recommend that you put salt directly in the skimmer box This is a very poor practice as it allows very high concentrations of salt WR EH SDVVHG WKURXJK RXU OWUDWLRQ DQG RWKHU SRRO HTXLSPHQW 6DOW LV WKH HVVHQWLDO HOHPHQW E ZKLFK RXU 8QLW RSHUDWHV QVXI FLHQW 6DOW ZLOO GDPDJH RXU HOO RECOMMENDED TDS LEVEL RANGE 4 000 6 000ppm WARNING Do not add Hydrogen Peroxide t...

Страница 16: ...ockwise Test your chlorine level again the following morning at around the same time If your chlorine level is still high repeat the above process until the correct level is attained SHOCK TREATMENT Periodically especially during extremely hot conditions it may be necessary to boost the amount of chlorine in your pool in order to maintain absolute sanitation of the water This can be achieved by ad...

Страница 17: ...by rain wind and dust There are QXPHURXV YDULHWLHV VRPH DUH IUHH ÀRDWLQJ ZKLOVW RWKHUV JURZ RQ ZDOOV DQG LQ FUDFNV and come in different colours Some are more resistant to chemical treatment than others Bacteria The germs that contaminate your pool Introduced by swimmers dust rain storms and other elements Balanced Water The correct ratio of mineral content and pH level that prevents pool water fr...

Страница 18: ...ting 6 Sanitiser fuse blown 7 Dirty Cell 8 Filter needs back washing 9 Flow switch not connected 10 QVXI FLHQW ZDWHU ÀRZ WKURXJK FHOO 11 Running times incorrect 12 Main house fuse blown 13 Pump motor faulty NOTES SERVICE HISTORY Low Chlorine Production Check for 1 Dirty Cell clean if required 2 Filter needs back washing 3 Cell failing 4 Pool stabiliser too low 5 pH too high 6 TDS level too low 7 R...

Страница 19: ...g from misuse or negligent handling improper use for which the product was not designed or advertised failure to properly follow the provided installation and operating instructions failure to carry out maintenance corrosive or abrasive water or other liquid lightning or high voltage spikes or unauthorised persons attempting repairs Where applicable your Davey product must only be connected to the...

Отзывы: