46
System Real-time Messages
Status
Description
1111 1000
Timing Clock
1111 1010
Start – starts the sequencer from step 1
1111 1011
Continue – re-starts the sequencer from the current step
1111 1100
Stop – Stops the sequencer
Universal System Exclusive Message (Device Inquiry)
Status
Description
1111 0000
System Exclusive (SysEx)
0111 1110
Non-realtime message
0vvv vvvv
If MIDI channel is set to 1-16, 0vvvvvvv must match (unless MIDI Channel
= ALL); always responds if 0vvvvvvv = 0111 1111.
0000 0110
Inquiry Message
0000 0001
Inquiry Request
1111 0111
End of Exclusive (EOX)
Evolver responds with:
Status
Description
1111 0000
System Exclusive (SysEx)
0111 1110
Non-realtime message
0vvv vvvv
If MIDI Channel = ALL, 0vvvvvvv = 0111 1111. Otherwise 0vvvvvvv =
Channel Number 0-15.
0000 0110
Inquiry Message
0000 0010
Inquiry Reply
0000 0001
DSI ID
0010 0000
Evolver ID (Family LS)
0000 0000
Family MS
0000 0000
Family Member LS
0000 0000
Family Member MS
0vvv vvvv
PIC Software version
0000 0000
0vvv vvvv
DSP Software version
0000 0000
1111 0111
End of Exclusive (EOX)