manualshive.com logo in svg
background image

Dashboard User Guide

8

Start

pedalling

Press the

function key

under “End”

Press the

Menu key

Turn and

press control

button to

select

“Setting”

Turn and

press control

button to

select “Name

& Addr.”

Turn and

press control

button to

select “Name”

Slider switch

lower position:

write protection

is deactivated.

Turn and

press control

button to

select

“Personal data”

Please use the ergo_memo-card2 with every training session to store your

personal settings and actual training data. This card is user related. It is not

possible to store the personal settings of a second user on the same card.

Note:

When you train without ergo_memo-card2 you will not have the possibility to

store training results.

The user controls the dashboard by means of the control button, the Menu

key, the Info key and two function keys.

Use the info key to obtain more information about the individual menu

items.

If the requested information spans many pages, you can leaf through the pages

by turning the control button. Press the Info key to display the keywords glossary

(page 12).

Note:

We reserve the right to modify the figures!

Insert the ergo_memo-card2 in the card reader before turning the device on.

Setting Personal Data

Before training you should enter your personal data and limit values under menu

item “Setting”.

User and device data can be set here.

Starting Training Without Selecting a Program

You  can  start  training  immediately  with  this  screen  displayed.

Switching ON (with ergo_memo-card2)

You can enter all the characters and special characters by turning and

pressing the control button. Use the position “Small” to switch between

capital and small characters as well as special characters. Use the “

<-

”

position to delete and correct your entry

Use the Info key to obtain more information about the individual menu items.

Содержание ergo_bike medical8

Страница 1: ...medical Operating Instructions 0650682e 0004 0297...

Страница 2: ...tting Personal Data 8 Starting Training by Selecting a Program 9 Training Programs 9 10 Setting Limit Values 10 11 Reviewing Stored Training Data 11 MP3 Player 12 Keywords Glossary 12 General Notes Im...

Страница 3: ...de come into contact with others conductive parts including the grounding while getting on the ergo_bike medical8 Please do never touch device parts conducting very low safety voltage and the patient...

Страница 4: ...estion from the device When providing a diagnosis the results must always be controlled and evaluated by a qualified physician The electronic installations of the rooms where the device will be used m...

Страница 5: ...rs 3 Handlebars continuously adjustable over 360 4 Clamp screw for the handlebars 5 Roller casters 6 Name plate 7 Potential equalisation 8 On Off switch 9 Height adjustment for the saddle 10 Saddle co...

Страница 6: ...ightening Pull and turn the lever to point to the rear risk of injury When switched on the system takes about 1 minute to load the software The colour screen displays during this time a software load...

Страница 7: ...d gear The value that can be actually modified will be colour highlighted in the training view 11 Audio connector Used to connect a headphone 12 Card reader for the ergo_memo card2 Underside 13 Reset...

Страница 8: ...ys Use the info key to obtain more information about the individual menu items If the requested information spans many pages you can leaf through the pages by turning the control button Press the Info...

Страница 9: ...e With the RPM controlled programs the wheel speed in revolutions per minute is maintained at a level defined by the user Training Programs Pulse Rate Training Programs With the pulse rate programs th...

Страница 10: ...or before setting the loading values after a few training units Dynamic Limit Values and Static Limit Values can be set Due to their natural variability dynamic limit values are continually exceeded S...

Страница 11: ...ton to select Setting Turn and press control button to select Personal data Turn and press control button to Select Training Unit Turn and press control button to Select Diagram Reviewing Stored Train...

Страница 12: ...rol button to start playing the selected title The system continues with playing all the music titles eventually following the selected one in the list The volume is controlled by means of the 2 dedic...

Страница 13: ...should still be slightly bent at the lower pedal position Fig A as for normal biking as opposed to the racing posture Fig B Environmental Conditions Ergometers are not suited for operation in areas o...

Страница 14: ...n Issue EN 1041 Informationen supplied by the manufacturer 1998 with medical devices EN 60601 1 A1 A2 Medical electrical equipment Part 1 General 1996 requirements for safety EN 60601 1 2 Medical elec...

Страница 15: ...plate located on the housing with your local supply voltage prior to plugging the power cord to the power supply Please contact you dealer if the values are not the same The device is completely disco...

Страница 16: ...for operating medical products and the known technical regulations and be repaired as needed Technical safety tests may only be executed by persons technicians with the proper education and knowledge...

Страница 17: ...upervision duty verified II Functions ON OFF switch verified EMERGENCY STOP device verified Controls mechanical verified Controls dashboard console verified III User manual The user manual was read an...

Страница 18: ...heet for the testing before placing into service and repeat testing of medical electrical devices or systems according to GEF German Electrotechnology Federation 0751 1 Next test date Remark Tester Si...

Страница 19: ...ty of medical products at daum electronic gmbh The device must be tested according to GEF German Electrotechnology Federation 0751 1 before it is put back into service Failure description Spare part I...

Страница 20: ...and only if you received the program in object code or executable form with such an offer in accord with Subsection b above The source code for a work means the preferred form of the work for making m...

Страница 21: ...distribution limitation excluding those countries so that distribution is permitted only in or among countries not thus excluded In such case this License incorporates the limitation as if written in...

Страница 22: ...f any to sign a copyright disclaimer for the program if necessary Here is a sample alter the names Yoyodyne Inc hereby disclaims all copyright interest in the program Gnomovision which makes passes at...

Страница 23: ......

Страница 24: ...daum electronic gmbh Flugplatzstr 100 D 90768 F rth Tel 49 0 911 97536 0 Fax 49 0 911 7537 14 www daum electronic de Stand 25042007...

Отзывы: