4. Mounting
4.1. General instructions
The instrument should be installing in the safe area in a
cabinet with sufficient IP protection, where the operating
conditions are in accordance with chapter
8.1 Technical
specifications
, as described under the title: Operating
conditions.
Mounting position
The instruments are designed in housing for mounting on
TS35 rail.
The instruments should be mounted in vertical position
(horizontal rail position).
There are spacers both sides of the housing to keep 5 mm
distance between the instruments for the sufficient cooling.
Horizontal mounting may cause overheating and damage of
the instrument.
4.2. Main dimensions of the instrument