5. Connecting

 

 

5.1. Preparing the connection

 

 
 

 

 

 

 
 
 
 
 

Select and prepare 
connection cable 

 
 
 
 

 

 

 

Always observe the following safety instructions: 

• 

When you are going to install instruments in hazardous 

area or install instruments which are connecting to 
instruments are working in hazardous area you

 

should take 

note of the appropriate regulations, conformity and type 
approval certificates of the DT1315 xx xx and other 
instrument. The connection must be carried out by trained 
and authorized personnel only! 

• 

Connect only in the complete absence of supply voltage 

• 

Use only a screwdriver with appropriate head 

 
Take note the suitability of the connecting cable 
(wire cross-section, insulation, etc.). 
The wire cross-section should be 0.25-1.5 mm

2

You may use either solid conductor or flexible conductor. 
In case of using flexible conductor use crimped wire end. 
 
Take note of the corresponding installation regulations for 
Ex applications. In particular, make sure that no potential 
equalization currents flow over the cable screen. Ground 
only one side the cable screen (it’s recommended the 
transmitter side). If necessary of grounding on both sides 
(for suppress the influence of high frequency interference 
signals) this can be achieved by use of a capacitor (e.g. 
ceramic capacitor 1 nF, 1500 V) or separate potential 
equalization. The low frequency potential equalization 
currents are thus suppressed, but the protective effect 
against high frequency interference signals remains. 
 

 

Содержание DT1315 Series

Страница 1: ...DT1315 xx xx Intrinsically Safe Output Isolators Operating Instructions...

Страница 2: ...2 7 Environmental instructions 6 3 Product description 7 3 1 Delivery configuration 7 3 2 Type designation 7 3 3 Principle of operation 7 3 4 Adjustment 8 3 5 Indicators 8 3 6 Storage and transport 8...

Страница 3: ...3 6 Fault rectification 14 6 1 Fault finding 14 6 2 Repairing 14 7 Dismounting 15 7 1 Dismounting procedure 15 7 2 Disposal 16 8 Appendix 17 8 1 Technical specification 17 8 2 Application example 19 8...

Страница 4: ...o these personnel and put into practice by them 1 3 Symbolism used Information tip note This symbol indicates helpful additional information Caution warning danger This symbol informs you of a dangero...

Страница 5: ...scription 2 3 Warning about misuse Inappropriate or incorrect use of the instrument can give rise to application specific hazards or damage to system components through incorrect mounting or adjustmen...

Страница 6: ...x areas These safety instructions are part of the operating instructions manual and come with the Ex approved instruments 2 7 Environmental instructions Protection of the environment is one of our mos...

Страница 7: ...ne 1 potentially explosive area The instruments isolate the input the output and the power supply The input signal may be 0 20 mA 4 20 mA 0 10 V the intrinsically safe output signal also may be 0 20 m...

Страница 8: ...torage and transport This instrument should be stored and transport in places whose climatic conditions are in accordance with chapter 8 1 Technical specifications as described under the title Environ...

Страница 9: ...ions as described under the title Operating conditions Mounting position The instruments are designed in housing for mounting on TS35 rail The instruments should be mounted in vertical position horizo...

Страница 10: ...he mounting doesn t need any tool 1 Tilt the instrument according to the figure put the instrument s mounting hole onto the upper edge of the rail figure step 1 2 Push the instrument s bottom onto the...

Страница 11: ...bility of the connecting cable wire cross section insulation etc The wire cross section should be 0 25 1 5 mm2 You may use either solid conductor or flexible conductor In case of using flexible conduc...

Страница 12: ...ful the polarity of the cables Checking the connections 1 Loosen terminal screws 2 Insert the wire ends into the open terminals according to the wiring plan 3 Screw the terminal in 4 Check the hold of...

Страница 13: ...s according to the wiring plan 3 Screw the terminal in 4 Check the hold of the wires in terminals by pulling on them firmly Check if the cables are connected properly have you connected all the cables...

Страница 14: ...supply voltage is OK the instrument is defective There is no output signal check the input signal If the input signal is OK the instrument is defective When the result of fault finding is that the DT1...

Страница 15: ...needs a screwdriver for slotted screws Pull out all the terminals 1 Put the screwdriver into the slot between the terminal and the housing figure step 1 2 Lift lower terminals or push down upper term...

Страница 16: ...l figure step 5 6 Lift the whole instrument you may put out the screwdriver figure step 6 as far as the instrument will be free 7 2 Disposal According with the concerning EU directive the manufacturer...

Страница 17: ...15 I0 xx or 4 20 mA DT1315 I4 xx or 0 10 V DT1315 U10 xx Input resistance current input 68 ohm Input resistance voltage input 1 Mohm Overdriving ability 5 Output parameters Output signal DC current or...

Страница 18: ...20 70 C Relative air humidity 90 max non condensing Place of installation safe area cabinet Installation with 5 mm space Electromagnetic compatibility EMC accordance with the standard EN 61326 2000 sz...

Страница 19: ...DT1315 xx xx 20100826 V0 19 8 2 Application example...

Страница 20: ...DT1315 xx xx 20 20100826 V0 8 3 ATEX Certification...

Страница 21: ...DT1315 xx xx 20100826 V0 21...

Страница 22: ...DT1315 xx xx 22 20100826 V0...

Страница 23: ...DT1315 xx xx 20100826 V0 23...

Страница 24: ...DT1315 xx xx 24 20100826 V0...

Страница 25: ...DT1315 xx xx 20100826 V0 25...

Страница 26: ...DT1315 xx xx 26 20100826 V0...

Страница 27: ...DT1315 xx xx 20100826 V0 27...

Страница 28: ......

Отзывы: