2.6. Safety information for Ex areas

 

 

Please note the Ex-specific safety information for installation
and operation in Ex areas. These safety instructions are 
part of the operating instructions manual and come with the 
Ex-approved instruments. 
 

 

2.7. Environmental instructions

 

 

Protection of the environment is one of our most important 
duties. 
Please take note of the instructions written in the following 
chapters: 

 Chapter 

3.4. Storage and transport

 

 Chapter 

8.2. Disposal 

 

 

Содержание DT1315 Series

Страница 1: ...DT1315 xx xx Intrinsically Safe Output Isolators Operating Instructions...

Страница 2: ...2 7 Environmental instructions 6 3 Product description 7 3 1 Delivery configuration 7 3 2 Type designation 7 3 3 Principle of operation 7 3 4 Adjustment 8 3 5 Indicators 8 3 6 Storage and transport 8...

Страница 3: ...3 6 Fault rectification 14 6 1 Fault finding 14 6 2 Repairing 14 7 Dismounting 15 7 1 Dismounting procedure 15 7 2 Disposal 16 8 Appendix 17 8 1 Technical specification 17 8 2 Application example 19 8...

Страница 4: ...o these personnel and put into practice by them 1 3 Symbolism used Information tip note This symbol indicates helpful additional information Caution warning danger This symbol informs you of a dangero...

Страница 5: ...scription 2 3 Warning about misuse Inappropriate or incorrect use of the instrument can give rise to application specific hazards or damage to system components through incorrect mounting or adjustmen...

Страница 6: ...x areas These safety instructions are part of the operating instructions manual and come with the Ex approved instruments 2 7 Environmental instructions Protection of the environment is one of our mos...

Страница 7: ...ne 1 potentially explosive area The instruments isolate the input the output and the power supply The input signal may be 0 20 mA 4 20 mA 0 10 V the intrinsically safe output signal also may be 0 20 m...

Страница 8: ...torage and transport This instrument should be stored and transport in places whose climatic conditions are in accordance with chapter 8 1 Technical specifications as described under the title Environ...

Страница 9: ...ions as described under the title Operating conditions Mounting position The instruments are designed in housing for mounting on TS35 rail The instruments should be mounted in vertical position horizo...

Страница 10: ...he mounting doesn t need any tool 1 Tilt the instrument according to the figure put the instrument s mounting hole onto the upper edge of the rail figure step 1 2 Push the instrument s bottom onto the...

Страница 11: ...bility of the connecting cable wire cross section insulation etc The wire cross section should be 0 25 1 5 mm2 You may use either solid conductor or flexible conductor In case of using flexible conduc...

Страница 12: ...ful the polarity of the cables Checking the connections 1 Loosen terminal screws 2 Insert the wire ends into the open terminals according to the wiring plan 3 Screw the terminal in 4 Check the hold of...

Страница 13: ...s according to the wiring plan 3 Screw the terminal in 4 Check the hold of the wires in terminals by pulling on them firmly Check if the cables are connected properly have you connected all the cables...

Страница 14: ...supply voltage is OK the instrument is defective There is no output signal check the input signal If the input signal is OK the instrument is defective When the result of fault finding is that the DT1...

Страница 15: ...needs a screwdriver for slotted screws Pull out all the terminals 1 Put the screwdriver into the slot between the terminal and the housing figure step 1 2 Lift lower terminals or push down upper term...

Страница 16: ...l figure step 5 6 Lift the whole instrument you may put out the screwdriver figure step 6 as far as the instrument will be free 7 2 Disposal According with the concerning EU directive the manufacturer...

Страница 17: ...15 I0 xx or 4 20 mA DT1315 I4 xx or 0 10 V DT1315 U10 xx Input resistance current input 68 ohm Input resistance voltage input 1 Mohm Overdriving ability 5 Output parameters Output signal DC current or...

Страница 18: ...20 70 C Relative air humidity 90 max non condensing Place of installation safe area cabinet Installation with 5 mm space Electromagnetic compatibility EMC accordance with the standard EN 61326 2000 sz...

Страница 19: ...DT1315 xx xx 20100826 V0 19 8 2 Application example...

Страница 20: ...DT1315 xx xx 20 20100826 V0 8 3 ATEX Certification...

Страница 21: ...DT1315 xx xx 20100826 V0 21...

Страница 22: ...DT1315 xx xx 22 20100826 V0...

Страница 23: ...DT1315 xx xx 20100826 V0 23...

Страница 24: ...DT1315 xx xx 24 20100826 V0...

Страница 25: ...DT1315 xx xx 20100826 V0 25...

Страница 26: ...DT1315 xx xx 26 20100826 V0...

Страница 27: ...DT1315 xx xx 20100826 V0 27...

Страница 28: ......

Отзывы: