20
5.
Firmware Update
Datavideo usually releases new firmware containing new features or reported bug fixes
from time to time. Customers can either download the TWP-10 firmware as they wish or
contact their local dealer or reseller for assistance.
This section outlines the firmware upgrade process which should take
approximately 10
minutes to complete
.
The existing TWP-10 settings should persist through the
firmware upgrade process, which
should not be interrupted once started
as this could result in a non-responsive unit.
Successful firmware upgrade on TWP-10 requires:
•
USB drive with LED indicator
•
Mini-USB to Female Type A USB cable
•
Latest firmware file
Procedure
•
Turn OFF the machine power (turn off the switch on the rear panel or unplug the
power cable)
•
Move the DIP switch to OFF position (down)
•
Connect a USB drive with at least an LED indicator to the mini-USB port of the TWP-
10 via the mini-USB to Female Type A USB cable (the USB drive should contain the
firmware file)
•
Connect the power
•
The firmware update is finished as soon as the USB drive indicator turns OFF
(approximately 20-30 seconds)
•
Disconnect the power
•
Unplug the mini-USB to Female Type A USB cable and move the DIP switch to ON
position (UP)
•
Turn ON the machine again to check the firmware version.