![Datavideo RMC-260 Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/datavideo/rmc-260/rmc-260_instruction-manual_513240023.webp)
23
GPI Out
This allows the user to perform GPI configuration. After turning on the GPI, select the GPI
mode
, which
is either level or pulse. The pulse width can also be configured in the sub-option
Width
(1-9). GPI out can
then be assigned to one of Inputs 1-6 and the
delay
can be set to between 1 and 99. This feature could
be used to trigger playback from an external playback device such as Datavideo’s NVP-20 or HRS-30 unit.
Multiviewer
AutoNum: The Multiview windows can be automatically numbered, and this sub-option turns ON/OFF
automatic numbering.
Label Inf: This sub-option turns ON/OFF Label information. Input label is followed by information which
describes the input as still, live or frozen image.
Trns Lab: This sub-option turns ON/OFF Label Transparency. Once enabled, the background of the label
is then turned from a solid colour to transparent.
4.8 Stills
Still allows the user to load images from the memory, save images to the memory, and save the images
captured.
Advanced Mode
Start
Load Still
Load
Still Num
13
Input 5
Keyer
Thumbnail
Picture - 1
Thumbnail Picture
Thumbnail
P 1
Chroma
P-in-P
P-in-P Lite
Save Still
Save
Input 5
Still Num
13
Inputs
Outputs
Freeze
1
Still
2
Live
3
Still
Stills
4
Still
5
Still
6
Live
User Mems
Setup
Basic Mode
Start
Load Still
Load
Still Num
13
Input 5
Keyer
Thumbnail
Picture - 1
Thumbnail Picture
Thumbnail
P 1
Chroma
P-in-P
P-in-P Lite
Save Still
Save
Input 5
Still Num
13
Inputs
Outputs
Stills
User Mems
Setup
Load Still
Upon selecting “Load Still”, the user can then choose the memory location from which the still image is
loaded. The following are the destinations to which the still image can be loaded:
•
Input 6
•
Input 5