8. Loading Software and Firmware
8.1 Loading DSV2+ Software Updates
The DsVerify2SoftwareUpdate application permits the user to download software updates from
several source locations are as list below:
•
CAB files located on \Storage Card 2, \Storage Card, and USB thumb drives
•
CAB files loaded directly from the Datastrip corporate FTP server, (requires a Datastrip
supplied) username and password that accesses a pre-determined account.
•
CAB files loaded from user/developer designated FTP servers, given a username and
password to a valid account.
8.1.1
DSV2+ Software Update Procedure - Using CF card in external slot
NOTE: It is recommended that upgrades are done with the unit operating on the AC adapter.
This upgrade process should take approximately 3.5 minutes to complete.
•
Power up unit.
•
Insert the provided CF Card containing the new OS cab file into the external CF slot.
•
When the device is finished booting, double tap My Computer and Select Storage Card /
DSVII.
•
Double tap the DsVerify2SoftwareUpdate utility.
•
Select Server: Storage Card2 (you must scroll down to make selection)
•
Username and Password are not necessary for this procedure
•
Select most recent appropriate source file (Ex. Src File: \DSVII_0195_sh4.CAB)
•
Click Update (This step will take approximately 2.5 minutes.
•
Click Reboot (The registry will be cleared prior to shutdown).
•
Power Up unit
•
The DSV2+ registration program will automatically open. Select the button for the
device that you are registering (DSVII-SC, DSVII-PA, or DSVII-SW). Select [OK] and
wait. (This process will take from a few seconds).
•
Click [Ok] in the “Hurray!” Box when it appears, then close the application window.
•
Double tap the RegistrySaver program.
•
Double tap My Computer and Select Storage Card / DSVII.
•
Double tap the PPCalFt41utility and press the “Calibrate” button to initialize the
fingerprint sensor. This process may take up to a minute and then a “green” window with
a number “1” should appear to indicate the sensor was successfully calibrated.
•
Double tap the DsVerifyFpCaptureTest application. In the lower right hand corner select
“UPEK” and click “OK”. DO NOT use the calibrate button on this screen for UPEK,
however you can use the Scan function to test the fingerprint image.
•
If you are upgrading a scanner go to Section 8.2
8.1.2
DSV2+ Software Update Procedure – Using Datastrip FTP site
NOTE: It is recommended that upgrades are done with the unit operating on the AC adapter.
This upgrade process should take approximately 13 minutes to complete.
•
Power up unit.
•
When the device is finished booting double tap My Computer and Select Storage Card /
DSVII.
•
Double tap the DsVerify2SoftwareUpdate utility
•
Select Server: datastrip.serveftp.net
•
Click Connect