PROPERTY OF DATASONICS

The information, descriptions, photos and illustrations in this manual are 
the property of Datasonics, Inc. These materials may not be reproduced 
or disseminated without the prior written consent of Datasonics.

WARRANTY

Datasonics, Inc. warrants each of its products to be free from defects in 
material and workmanship for a period of one year from date of delivery 
to the original purchaser.

Obligation under this warranty shall be limited to the repair or, at the sole 
discretion of Datasonics, replacement of any product returned to our 
Cataumet, Massachusetts, facility or to a Datasonics-authorized field 
service facility. All products returned shall be shipped to Datasonics 
Freight Prepaid, and shall be returned to the customer Freight Collect.

This warranty does not apply in cases where the equipment 
malfunctioned as a result of mishandling or improper operation.

LIABILITY

Datasonics assumes no liability for damages, losses or costs incurred 
consequentially through operation or malfunction of any Datasonics 
product.

TITLE

Title passes to the buyer on deliver to the carrier at Cataumet, 
Massachusetts. Risk of damage or loss following such delivery shall be 
on the buyer, and Datasonics shall in no way be responsible for safe 
arrival of the shipment. Title shall pass to the buyer regardless of any 
provision for payment of freight or insurance by Datasonics, and 
regardless of the form of the shipping documents. If the shipment is 
consigned to Datasonics, it shall be for the purpose of securing the 
buyer's obligations under the contract.

CHANGES

Datasonics reserves the right to make changes in design or 
specifications at any time without incurring any obligation to modify 
previously installed units.

This manual is provided for informational and reference purposes only 
and is subject to change without notice. 

Содержание PSA-916

Страница 1: ...Datasonics Inc PSA 916 Sonar Altimeter User s Manual Rev March 1997 Datasonics Inc P O Box 8 1400 Route 28A Cataumet MA 02534 Telephone 508 563 5511 Fax 508 563 9312...

Страница 2: ......

Страница 3: ...ment malfunctioned as a result of mishandling or improper operation LIABILITY Datasonics assumes no liability for damages losses or costs incurred consequentially through operation or malfunction of a...

Страница 4: ...chasing a Datasonics PSA 916 Precision Sonar Altimeter This User Manual provides complete instructions on using and maintaining the PSA 916 Please read it prior to deploying the equipment and keep it...

Страница 5: ...mer Feedback Form to identify any areas where we can make improvements For returning this form you will receive a complimentary gift from Datasonics Copy this page to provide individual forms Please r...

Страница 6: ...S 232 Output 3 Error Output 4 Analog Output 4 External Key 4 Configuration 5 Predeployment 5 Deployment 6 Maintenance 7 Section 4 Theory of Operation 4 1 Operating Principle 4 1 Board level descriptio...

Страница 7: ...Section 6 Drawing List 6 1...

Страница 8: ...from the target surface The unit provides range data in both analog and digital formats for analysis and process control The PSA 916 is housed in a corrosion resistant anodized aluminum pressure case...

Страница 9: ...meets a wide variety of sonar measurement applications with a single self contained instrument The most common use of the Model PSA 916 Sonar Altimeter is for altitude measurement height above bottom...

Страница 10: ...to 5 pulses per second RANGE 100 meters full scale 1 0 meter guaranteed minimum 0 8 meter typical ANALOG OUTPUT 0 to 5 VDC DIGITAL OUTPUT RS 232 baud rate 9600 4800 2400 or 1200 user selectable RESOL...

Страница 11: ...anges to the dip switches will change the configuration Refer to Section 3 3 Table 6 1 Configuration Standard FSI Mode Custom Description of Configuration Key SW 1 2 Internal External Serial Output SW...

Страница 12: ...listed below Store the shipping cartons and packing materials in a cool dry place for later use in system transport The unit is shipped completely assembled and internally configured Should an interna...

Страница 13: ...e are items missing or if you suspect that there has been any damage to the equipment contact Datasonics immediately 3 2 Connection The PSA 916 outputs data and receives power through a 6 pin connecto...

Страница 14: ...t the PSA 916 3 2 2 RS 232 Output The RS 232 output is set to the following parameters Baud 1200 2400 4800 or 9600 user selectable Number of Data Bits 8 Number of Stop Bits 1 Parity none On power up t...

Страница 15: ...e averaging criteria then this line will be high Essentially this line is high whenever it would be necessary to output an E on the serial output This line also goes high if error condition E1 occurs...

Страница 16: ...he unit can transmit and receive acoustic signals and that the system parameters are correctly set Description SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 Test mode see section 4 4 ON ON External key 200 MS min b...

Страница 17: ...98V Note that if under range detection is enabled verify the RS 232 output is 0 8 and the analog output is 39 8 mv If under range detection is not enabled tap on transducer face with fin ger and verif...

Страница 18: ...e sure the altimeter is attached to the bottom of the ROV so that it is not affected by echos from the skids In applications using multiple altimeters within each others range their transmissions shou...

Страница 19: ...ompletion of a project follow these preventive maintenance procedures Turn the unit OFF by unplugging the mating connector Clean the exterior of the pressure casing and transducer with fresh water and...

Страница 20: ...eter can determine the range utilizing this equation R 1 2 Cs t t Where Cs the speed of sound in meters per second t the total round trip travel time in seconds R range in meters The nominal speed of...

Страница 21: ...t of U2 is sent to the power MOSFET driver U3 U3 inverts the pulses and drives MOSFET Q1 Q1 in turn drives transformer T1 Which steps up the voltage and drives the transducer The inductance of the out...

Страница 22: ...nerates the key pulse which causes a 200khz burst to be transmitted as described in section 4 2 2 The transmission is detected by interrupt 1 which starts a 1 s timer If the transmission is not detect...

Страница 23: ...range is skipped than an E is appended to the data and the error output is goes to a logic 1 4 4 Diagnostics 4 4 1 Analog output The analog output can be tested by using the DIP switches to put the al...

Страница 24: ...it cycle and amplified output of the receiver Note that the scope capacitance will alter the signal TP5 Transmitter Key Normally 0 VDC during transmit it is at 0 6 VDC lasting for 250us TP6 2 5 VDC TP...

Страница 25: ...ection 5 Packing List Ref Qty Part No Manufacturer Description 1 1 007216 Datasonics Inc PSA 916 Top Assembly 2 1 RMG 6 FS Impulse Connector 6 pin pigtail 3 1 RMG 6 FSD HP Impulse Connector 6 pin dumm...

Страница 26: ...6 1 DATASONICS User s Manual March 1997 Section 6 Drawing List Drawing Number Description C916 06812 Assy Altimeter Board D916 07008 Schematic...

Отзывы: