PSA-916 Sonar Altimeter

3-4

Setup and Deployment

Connection

where xx.xx can range from 0.80 to 99.99. If no echo was received the output 
will be R99.99E<cr><lf>. If an echo was missed or the value does not meet 
the averaging criteria then an “E” will be appended to the previous value. If 
under range detection is selected and the value is under range then a ‘<’ will 
be appended to the data.

If the unit is not functioning correctly, “E1,<cr><lf>” will be output. If this 
occurs see section 4.4.3.

3.2.3 Error Output

This output is useful for indicating the validity of the data whenever the analog 
output is the source of range output. This line will be a logic 1 (5 volts) 
whenever no echo was detected in the last range interrogation cycle. If 
averaging is enabled and the data does not meet the averaging criteria then 
this line will be high. Essentially this line is high whenever it would be 
necessary to output an E on the serial output. This line also goes high if error 
condition E1 occurs. If this line is low it can be assumed that the altimeter is 
functioning normally and the analog output is valid.

3.2.4 Analog Output

The analog output ranges from 0 VDC to 4.98 VDC, Which represents 0.00 
to 99.99 meters. Note that if no echo is received, the output will go to full scale 
(4.98 VDC).

3.2.5 External Key

This line is used to tell the PSA-916 to take a range reading. The altimeter 
looks for a transition from a logic 1 (5 volts) to a logic 0 (0 volts). Once the 
transition is detected the altimeter will take a range reading and wait 200ms 
before looking for the next transition. Thus the minimum time between key 
pulses is 200ms. However there is no maximum limit to the time between key 
pulses. Note that the analog value will be valid 200ms after sending the 
external key.

Содержание PSA-916

Страница 1: ...Datasonics Inc PSA 916 Sonar Altimeter User s Manual Rev March 1997 Datasonics Inc P O Box 8 1400 Route 28A Cataumet MA 02534 Telephone 508 563 5511 Fax 508 563 9312...

Страница 2: ......

Страница 3: ...ment malfunctioned as a result of mishandling or improper operation LIABILITY Datasonics assumes no liability for damages losses or costs incurred consequentially through operation or malfunction of a...

Страница 4: ...chasing a Datasonics PSA 916 Precision Sonar Altimeter This User Manual provides complete instructions on using and maintaining the PSA 916 Please read it prior to deploying the equipment and keep it...

Страница 5: ...mer Feedback Form to identify any areas where we can make improvements For returning this form you will receive a complimentary gift from Datasonics Copy this page to provide individual forms Please r...

Страница 6: ...S 232 Output 3 Error Output 4 Analog Output 4 External Key 4 Configuration 5 Predeployment 5 Deployment 6 Maintenance 7 Section 4 Theory of Operation 4 1 Operating Principle 4 1 Board level descriptio...

Страница 7: ...Section 6 Drawing List 6 1...

Страница 8: ...from the target surface The unit provides range data in both analog and digital formats for analysis and process control The PSA 916 is housed in a corrosion resistant anodized aluminum pressure case...

Страница 9: ...meets a wide variety of sonar measurement applications with a single self contained instrument The most common use of the Model PSA 916 Sonar Altimeter is for altitude measurement height above bottom...

Страница 10: ...to 5 pulses per second RANGE 100 meters full scale 1 0 meter guaranteed minimum 0 8 meter typical ANALOG OUTPUT 0 to 5 VDC DIGITAL OUTPUT RS 232 baud rate 9600 4800 2400 or 1200 user selectable RESOL...

Страница 11: ...anges to the dip switches will change the configuration Refer to Section 3 3 Table 6 1 Configuration Standard FSI Mode Custom Description of Configuration Key SW 1 2 Internal External Serial Output SW...

Страница 12: ...listed below Store the shipping cartons and packing materials in a cool dry place for later use in system transport The unit is shipped completely assembled and internally configured Should an interna...

Страница 13: ...e are items missing or if you suspect that there has been any damage to the equipment contact Datasonics immediately 3 2 Connection The PSA 916 outputs data and receives power through a 6 pin connecto...

Страница 14: ...t the PSA 916 3 2 2 RS 232 Output The RS 232 output is set to the following parameters Baud 1200 2400 4800 or 9600 user selectable Number of Data Bits 8 Number of Stop Bits 1 Parity none On power up t...

Страница 15: ...e averaging criteria then this line will be high Essentially this line is high whenever it would be necessary to output an E on the serial output This line also goes high if error condition E1 occurs...

Страница 16: ...he unit can transmit and receive acoustic signals and that the system parameters are correctly set Description SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 Test mode see section 4 4 ON ON External key 200 MS min b...

Страница 17: ...98V Note that if under range detection is enabled verify the RS 232 output is 0 8 and the analog output is 39 8 mv If under range detection is not enabled tap on transducer face with fin ger and verif...

Страница 18: ...e sure the altimeter is attached to the bottom of the ROV so that it is not affected by echos from the skids In applications using multiple altimeters within each others range their transmissions shou...

Страница 19: ...ompletion of a project follow these preventive maintenance procedures Turn the unit OFF by unplugging the mating connector Clean the exterior of the pressure casing and transducer with fresh water and...

Страница 20: ...eter can determine the range utilizing this equation R 1 2 Cs t t Where Cs the speed of sound in meters per second t the total round trip travel time in seconds R range in meters The nominal speed of...

Страница 21: ...t of U2 is sent to the power MOSFET driver U3 U3 inverts the pulses and drives MOSFET Q1 Q1 in turn drives transformer T1 Which steps up the voltage and drives the transducer The inductance of the out...

Страница 22: ...nerates the key pulse which causes a 200khz burst to be transmitted as described in section 4 2 2 The transmission is detected by interrupt 1 which starts a 1 s timer If the transmission is not detect...

Страница 23: ...range is skipped than an E is appended to the data and the error output is goes to a logic 1 4 4 Diagnostics 4 4 1 Analog output The analog output can be tested by using the DIP switches to put the al...

Страница 24: ...it cycle and amplified output of the receiver Note that the scope capacitance will alter the signal TP5 Transmitter Key Normally 0 VDC during transmit it is at 0 6 VDC lasting for 250us TP6 2 5 VDC TP...

Страница 25: ...ection 5 Packing List Ref Qty Part No Manufacturer Description 1 1 007216 Datasonics Inc PSA 916 Top Assembly 2 1 RMG 6 FS Impulse Connector 6 pin pigtail 3 1 RMG 6 FSD HP Impulse Connector 6 pin dumm...

Страница 26: ...6 1 DATASONICS User s Manual March 1997 Section 6 Drawing List Drawing Number Description C916 06812 Assy Altimeter Board D916 07008 Schematic...

Отзывы: