a.
the DC port via a 12-48V DC 30W or higher power supply unit. No accessories are
powered by the DN200 as PoE out is not enabled.
b.
PoE in via any of the two Ethernet ports. This configuration can be achieved using a
PoE injector or by PoE setup already in place at site.
2.
The DN200 is powered using supplied PSU and PoE OUT is enabled: In such a mode, the
DN200 is used to power one or two PoE based systems like cameras, accessories etc. In such a
configuration, the unit should be powered by a 48V DC 60W Power supply through the DC IN
port.
ONLY.
A maximum output of 15W at 48V can be supplied per PoE port. Please make
sure good quality CAT 5 or higher cable is used. This configuration uses NON STANDARD
PoE implementation and it is important that a Datasat approved engineer is only used for such
an install
3.
The DN200 is powered over Ethernet via a PoE injector: In such a case, the PoE injector used
should be at least rated to 30W. In such a mode the DN200 cannot power any cameras or
accessories.
To summarize the PoE configurations, the DN200 can either be used as a PoE IN (accept PoE) or a PoE
OUT (power devices using the DN200) mode. This mode needs to defined during the order process so
the correct unit is supplied
1.6
System Configuration