Viper User
Manual (001-5008-000 Rev6)
Page
38
CWID
Continuous Wave Identification - Default = Disabled
Allows the user to broadcast their FCC call sign.
CWID Call sign is the user's FCC call sign to be broadcast.
CWID Interval is the time interval in minutes that the call sign will be broadcasted.
CWID can be configured under Setup (Basic)
D
General.
IP Forwarding Mode
Displays IP forwarding mode (Bridge or Router). The IP Forwarding Mode can be configured
under Setup (Basic)
D
General
D
IP Forwarding Mode.
Station relay point
Displays if the unit is being used as a relay point (Yes or No). The Station Relay Point can be
configured under Setup (Basic)
D
General
D
Station relay point.
On-line diagnostics Interval
Displays the time interval in seconds when the On-line Diagnostics will be transmitted. This
interval can be configured under Setup (Basic)
D
General
D
On-line diagnostics interval.
Unit Status
Displays the status of the Viper and reports any errors. If you do not receive the OK
indicator (EX. Error: Power On Self Test FAILURE, Warning: Radio TX Synthesizer lock
failure N/A), use the ACKNOWLEGDE UNIT STATUS and REFRESH buttons to reset the
modem. If the problem persists, contact CalAmp Technical Services for additional
information.
Have the displayed Unit Status message available if contacting CalAmp support. This
information is also required if returning a unit for service under RMA.
Refresh
Button will refresh the parameters on the current page.
Acknowledge Unit Status
This button allows the user to acknowledge and clear errors.
Errors remain stored, even after cycling power, to aid in troubleshooting intermittent faults.
Press the "Acknowledge Unit Status" button to return web page displays and Status LED
function to normal operation.
DIAGNOSTICS
Viper units continually monitor and report on their environmental and operating conditions.
1.1.28
Local Diagnostics
Local Diagnostics can be accessed by loading the Unit Status
D
Diagnostics web page from
the Viper.