Paragon4 – UHF, 700, & 800MHz User Manual
11
3.1.2 Exciter module
The Exciter’s front panel controls and indicators are:
•
Carrier test - momentarily keys the transmitter ON while pressed (used for
test purposes only). If the Carrier is pressed for 4 seconds or more the ex-
citer starts the test mode and keeps transmitting until the next press of the
button.
•
LED indicators, according to the table below.
•
one DE-9 RS-232 ports for setup.
Figure 6 - Exciter module
3.1.3 BSC module
The BSC2's front panel connectors and indicators are:
Green
Normal operation
Amber
Step 2 in uMon boot-up – lights for <1 sec.
Red
Step 1 in uMon boot-up – lights for <1 sec.
PWR
LED
Red
flashing
Hardware error, must check the log files to
identify it
Green
Flashes for each data packets received
RX LED
Red
Discard RX packet (factory-use)
Green
Flashes for each data packets transmitted
Amber
Flashes for each data packets transmitted
(check for lost Host connection)
Red
Continuoulsy ON for TXON test (max. 20
secs.)
Flashes ON for CWID key-up event
TX LED
Off
Check if in “AirLink down mode”
Green
Flashes each time PF1 or PF2 is pressed
STATUS
Amber
Flashes each second PF1 is kept pressed
Toggles “AirLink down mode” after 4 sec-
onds
•
2x DE-9 RS-232 ports for setup and user data
Figure 7 - BSC module
•
1x rocker switch (positions PF 1 and 2) to select various test modes. See paragraph 5.3.2.
•
2x Ethernet ports – for setup and user data
Green
Red
flashingAmber
Off
Power
normal
Fault 1 (TBD)
fault 2 (TBD)
TX
transmit
Test Mode:
idle
10 MHz
10 MHz
Locked
10 MHz con-
nection broken,
unable to lock
Acquiring 10
MHz Lock
Idle if 10 MHz
was never
connected.
Lock
normal,
Synth lock
Synth unlock
Fault
Programming
mode
LOCK
PWR
TX
Ext. 10MHz
COM
Carrier Test
SDR
Exciter
®
PWR
TX
BSC
ETH 2
RX
USB
ETH 1
COM 2
COM 1
STATUS