Indicators
The K-415 provides 5 indicator lamps.
POWER :
Indicates that A/C power is applied to the K-415
1-4
Indicates which of the four outlets is ON
Positive Feedback
MP-415 monitors the status of the outlets and reports its actual status. If the status detected does not
match the command given over the phone, MP-415 will report an ‘ERROR’. An error will also be reported
when obtaining status of outlets 5-8 if no expansion unit is installed. To correct this, change the setting for
the number of active ports to 4.
CONNECTIONS TO MP-415
Input: MP-415
Standard NEMA 5-15 Plug on 6 foot 14/3 line cord - 120VAC
MP-420
NEMA 5-20P Plug on 12/3 line cord -120 VAC. Requires 20 AMP service.
Outputs: 1-4
Standard NEMA 5-15 Receptacle.
MP-415 Combined maximum load must not exceed 12 Amps.
MP-420 Combined maximum load must not exceed 16 Amps.
Line:
Connect the Telephone Line
EXT:
Connect any telephone device (optional)
Control
Expansion for K-415 for Switched Outlets 5-8
This connection provides expansion of circuits 5-8 to Dataprobe’s K-415 four outlet power
strip. Use cable # PAL-K415, supplied with the K-415. For connection to other devices,
consult Dataprobe.
1 2 3 4
15A
1 2 3 4
EXT Line
Control
MP-415
K-415
Expansion Unit
PAL-K415
Expansion Cable