MULTIPAL OPERATING COMMANDS 

 

After MP-415 has answered a call, and depending on the answer and security mode previously selected, 
the following commands may be entered to operate MP-415. 

 

1- 8   Report Status of an Outlet 

MP-415  will report ‘ON’ or ‘OFF’ as indicated by the current outlet status.   MP-415 will also report 
‘ERROR’ if the controller cannot set the switch into the desired position.  Once an outlet is 
selected, it can then be changed by entering a # or 

«

 to toggle or pulse. 

 

#   

Change Status of an Outlet   

 

MP-415 will toggle the currently selected (or all if 9 is used) outlet and report the new status. 

 

«

  

Reset  an Outlet 

 

 

The MP-415 will pulse the outlet for the number of seconds determined by the Reset Time setting 
 

9   

Report Status of All Outlets

 

MP-415 will read off the status of all outlets.  The number of outlets reported is controlled by the 
Active Ports setting.   
 

91    Turn All Outlets On

 

MP-415 will turn all active outlets On, then read off the status of all outlets.  
 

92    Turn  All Outlets Off

 

MP-415 will turn all active outlets Off, then read off the status of all outlets.  

 

0     Ring Extension 
 

MP-415 will ring the EXT port.  No additional switch commands will be accepted by MP-415

 

 

 

Example:     You Send           MP-415 Does This         MP-415 Says This  

 

  

 

 

  

 

 

   “ 1 ON ”              

 

          #  

     Turn off Outlet 1    “ 1 OFF ” 

 

 

 

 

 

 

 

   “ 3 ON ” 

    

     

         

«

   

     Turn Off Outlet 3            “ 3 OFF Reset ” 

 

 

  

     Wait (Reset Time) 

 

 

 

 

     Turn On Outlet 3             “ 3 ON Reset ” 

 

 

 

91 

     Turn On All Outlets

   

     “ 1 On, 2 On……”

 

Содержание MP-415

Страница 1: ...dial telephone to access interrogate and control four A C power outlets Except were noted both models will be refered to as the MP 415 in this manual Each of the four outlets on the MP 415 can be ind...

Страница 2: ...prong adapter at the receptacle use of this type adapter may result in risk of electrical shock and or damage to this product 9 Do not allow anything to rest on the power cord Do not locate this prod...

Страница 3: ...r of rings before MP 415 answers the call security codes required for MP 415 to accept operating commands and how the call is passed on to the Extension Port can all be selected prior to use Normal An...

Страница 4: ...tions If the correct code is entered MP 415 will respond PAL Ready If the wrong code is entered MP 415 does not respond and the extension will be rung If MP 415 is set for control and ringing to the e...

Страница 5: ...wer Prompt Default 2 Answer Quiet MP 415 Answers Call on of Rings 2 n n Number of Rings 1 6 Default 2 MP 415 Rings to the Extension 7 n n Number of Rings 1 6 Default 4 Security Type Select 5 n 0 Secur...

Страница 6: ...d report the new status Reset an Outlet The MP 415 will pulse the outlet for the number of seconds determined by the Reset Time setting 9 Report Status of All Outlets MP 415 will read off the status o...

Страница 7: ...ports to 4 CONNECTIONS TO MP 415 Input MP 415 Standard NEMA 5 15 Plug on 6 foot 14 3 line cord 120VAC MP 420 NEMA 5 20P Plug on 12 3 line cord 120 VAC Requires 20 AMP service Outputs 1 4 Standard NEMA...

Страница 8: ...probe Technical Service at 201 967 8788 to receive a Return Materials Authorization RMA Number prior to sending any equipment back for repair Include all cables power supplies and proof of purchase wi...

Отзывы: