background image

 
 

Models MP-415, MP-420 

 

 

Page 4 

any control digit if no security code is required.  If no control tones are received in 6 seconds, MP-415 will 
ring the Extension when no security code is required. 
 

Use the Answer and Prompt Mode if:

  you want to know exactly when to enter security 

and control codes. 

 
If MP-415 is set for security on control only, type 1,  the code may be entered when prompted to gain 
access to MP-415’s control functions.  If the correct code is entered, MP-415 will respond 

“PAL Ready

“. If 

the wrong code is entered, MP-415 responds 

“Error”

  and the sender may try once more before the 

extension is rung. If MP-415 is set for control and ringing to the extension security type 2,  if the wrong 
code is entered twice, or no code is entered, the call will be terminated, dropped by MP-415.

  

In the 

program mode to set MP-415 for the Answer and Prompt mode, enter 6 plus 1 followed by  

 key. 

Answer And Quiet Mode 

MP-415 will answer the call and be quiet for six seconds, waiting for control codes.  If none are received 
within 6 seconds, MP-415 will ring the Extension. 
 

Use the Answer and Quiet Mode if:

  You want more secure control of power and the 

shortest time before the extension is rung. 

 
If MP-415 is set for security on control only, type 1,  the code may be entered during the 6 sec quiet 
time to gain access to MP-415’s control functions.  If the correct code is entered, MP-415 will respond 

“PAL Ready

 “. If the wrong code is entered, MP-415 does not respond,  and the extension will be rung. 

If MP-415 is set for control and ringing to the extension security, type 2,  if the wrong code is entered, 
or no code is entered, the call will be terminated, dropped by MP-415. With the right code, MP-415 
answers  

“PAL Ready

”.  To program MP-415 for the Answer and Quiet mode, enter 6 plus 2 followed 

the 

 key. 

 

Number of Rings before MP-415 Answers the Call       (Default = 2)

 

MP-415 can be set to answer calls after it detects a set number of rings from 1-6. To program the number 

of rings, enter 2 followed by the desired number, followed by the

 

’. 

 

Example . To have MP-415 answer 

in 4 rings, in the program mode, enter 2 4  

’.

 

MP-415 responds

 “OK”

  if the entry was accepted, 

“Error

” 

if not. 

Number of Rings to the Extension      (Default = 4) 

MP-415 can be set to ring the extension a number of times before the call is terminated. Enter 7 plus the 

desired number, 1-6 followed by the 

’. 

 

Example : 74 

’. 

 Will ring extension four times. 

Security Mode      (Default = no security) 

The security modes are set by entering 5 plus 0, 1, or 2 

’. 

 0 = no security, 1 for control only,  

and 2 for security for all functions, control and extension ring.  

Example: to set for security on control only. Enter 51

’.

 

Setting a Security Code      (Default = none set) 

To program a security code, enter the ‘#’ key followed by up to six number characters, followed by the  

’ 

key.  Example; to set a security code of 3451, enter #3451 

’.

 

MP-415 responds  

OK

 if entry is 

accepted or 

Error  

if not. 

Содержание MP-415

Страница 1: ...dial telephone to access interrogate and control four A C power outlets Except were noted both models will be refered to as the MP 415 in this manual Each of the four outlets on the MP 415 can be ind...

Страница 2: ...prong adapter at the receptacle use of this type adapter may result in risk of electrical shock and or damage to this product 9 Do not allow anything to rest on the power cord Do not locate this prod...

Страница 3: ...r of rings before MP 415 answers the call security codes required for MP 415 to accept operating commands and how the call is passed on to the Extension Port can all be selected prior to use Normal An...

Страница 4: ...tions If the correct code is entered MP 415 will respond PAL Ready If the wrong code is entered MP 415 does not respond and the extension will be rung If MP 415 is set for control and ringing to the e...

Страница 5: ...wer Prompt Default 2 Answer Quiet MP 415 Answers Call on of Rings 2 n n Number of Rings 1 6 Default 2 MP 415 Rings to the Extension 7 n n Number of Rings 1 6 Default 4 Security Type Select 5 n 0 Secur...

Страница 6: ...d report the new status Reset an Outlet The MP 415 will pulse the outlet for the number of seconds determined by the Reset Time setting 9 Report Status of All Outlets MP 415 will read off the status o...

Страница 7: ...ports to 4 CONNECTIONS TO MP 415 Input MP 415 Standard NEMA 5 15 Plug on 6 foot 14 3 line cord 120VAC MP 420 NEMA 5 20P Plug on 12 3 line cord 120 VAC Requires 20 AMP service Outputs 1 4 Standard NEMA...

Страница 8: ...probe Technical Service at 201 967 8788 to receive a Return Materials Authorization RMA Number prior to sending any equipment back for repair Include all cables power supplies and proof of purchase wi...

Отзывы: