background image

Technical Support Hotline:  (201) 967-8788

Technical Support:   201-934-5111

Main:   201-934-9944

[email protected]
Website: dataprobe.com

QUICK START

 

1)  

Plug a phone line into the jack marked LINE 

2)  

Plug the A/C line cord into an outlet.  

     The MP-420 requires a 20 service feed and NEMA 5-20R outlet.

 

3)  

Connect any A/C powered devices into the outlets on the MP-415, MP-420.   

 
The maximum current rating for all of the devices connected to the  
MP-415 cannot add up to more than 12 Amps.  
 
The maximum current rating for all of the devices connected to the  
MP-420 cannot add up to more than 16 Amps.

 

 
4)  Call the phone number connected to the unit.  The switch will answer with “PAL READY” 
5)  Enter ‘1’  The MP-4xx will respond with   ‘ 1  On’ 
6)  Enter ‘#’  Outlet 1 will turn off and the MP-4xx will respond with   ‘1  Off ’ 
7)  Repeat steps 5 and 6, entering 1 - 4 for the desired outlet. 
8)  Hang up when finished 
9)  Read the rest of the manual.  There are many more features and options. 

 
GENERAL DESCRIPTION

 

 

The MultiPAL Remote Controlled 
Power Strip, models MP-415 and  
MP-420 allow an operator with a 
tone dial telephone to access, 
interrogate and control four A/C 
power outlets. (Except were noted 
both models will be refered to as 
the MP-415 in this manual) Each of 
the four outlets on the MP-415 can 
be independently turned on, off or 
pulsed for power-on reset.  The 
unique MultiPAL controller allows 
the switch to be placed in series with any normal telephony device (phone, fax, modem, etc.).  Normal 
calls can pass transparently through MP-415; only when you enter a DTMF (touch tone) code, will the MP-
415 respond and allow switch control. 

 

To operate the MP-415, place a telephone call to the dial line connected to the unit.  The MP-415 provides 
three call answer modes and several security options.  When the call is validated, MP-415 will read off the 
current status of the switch  and then prompt the caller to change the switch position.  When a change is 
made, the new status is repeated and additional changes can be made.  When no more changes are 
required, the caller can hang-up, or send an additional code to access any extension device connected to 
the MP-415. 

Tone Controlled Power Strip 

With MultiPAL Voice Response

 

Model MP-415, MP-420

 

D i a l   L i n e

Call Pass-thru

"Switch 1

i s   O N "

4   P o w e r   C o n t r o l l e d
D e v i c e s

E x p a n s i o n   t o   4
Additional Outlets

 

REF:  PWR\MP-415_V030613D.DOC

 

Содержание MP-415

Страница 1: ...dial telephone to access interrogate and control four A C power outlets Except were noted both models will be refered to as the MP 415 in this manual Each of the four outlets on the MP 415 can be ind...

Страница 2: ...prong adapter at the receptacle use of this type adapter may result in risk of electrical shock and or damage to this product 9 Do not allow anything to rest on the power cord Do not locate this prod...

Страница 3: ...r of rings before MP 415 answers the call security codes required for MP 415 to accept operating commands and how the call is passed on to the Extension Port can all be selected prior to use Normal An...

Страница 4: ...tions If the correct code is entered MP 415 will respond PAL Ready If the wrong code is entered MP 415 does not respond and the extension will be rung If MP 415 is set for control and ringing to the e...

Страница 5: ...wer Prompt Default 2 Answer Quiet MP 415 Answers Call on of Rings 2 n n Number of Rings 1 6 Default 2 MP 415 Rings to the Extension 7 n n Number of Rings 1 6 Default 4 Security Type Select 5 n 0 Secur...

Страница 6: ...d report the new status Reset an Outlet The MP 415 will pulse the outlet for the number of seconds determined by the Reset Time setting 9 Report Status of All Outlets MP 415 will read off the status o...

Страница 7: ...ports to 4 CONNECTIONS TO MP 415 Input MP 415 Standard NEMA 5 15 Plug on 6 foot 14 3 line cord 120VAC MP 420 NEMA 5 20P Plug on 12 3 line cord 120 VAC Requires 20 AMP service Outputs 1 4 Standard NEMA...

Страница 8: ...probe Technical Service at 201 967 8788 to receive a Return Materials Authorization RMA Number prior to sending any equipment back for repair Include all cables power supplies and proof of purchase wi...

Отзывы: