3. Hardware Installation
3.1.
Ethernet Connections
iBoot-DC supports 10/100 Ethernet using the cable supplied, or other
suitable unshielded twisted pair (Cat 5) cabling. Activity (green) and
100Mb (amber) LEDs on the network connector indicate when the
network connection is properly established and when the connection
is 100 Mbit/s.
3.2.
DC Power Connections
iBoot-DC uses screw terminal connections for the DC input and
switched output connections. The screw terminals can be removed to facilitate connection and cable
fabrication.
Maximum Operating Current
5.0 to 29.9 VDC
12 Amps
30.0 to 48.0 VDC
2 Amps
The Positive lead is switched. When ON, the power will be at the NO connection. When OFF, the power
will be at the NC connection.
The chassis ground is optional and not switched.
An LED Indicator market Output will be on when the power to the NO connection is On.