background image

Operation

17

Operation

The illustration on the previous page shows the input source connected to Input 1 (HDMI1) on the Fx4 and each monitor  
connected to the respective output connector.

Where more than four outputs are required, (the example below shows eight) the 

Auto Config Fx4

 function  will determine the 

most logical way to connect all devices.  The blue output connector on the first Fx4 represents the DisplayPort Out Loop 

 

connector which is used to daisy chain additional Fx4’s if more outputs are required.  To daisy chain a second Fx4, use a 

 

DisplayPort cable (not supplied) to connect the DisplayPort 

Out Loop on the first Fx4 to the DisplayPort Input on the 

 

second Fx4. 

DisplayPort Out Loop

DisplayPort In

To associate the virtual Fx4 in the main window with an actual physical device, highlight the device by right clicking then select 

Associate Device

 from the displayed menu, a list of available Fx4’s is displayed.  

Click on the virtual device to display its properties, the 

Device Properties

 can be changed if required, for example you may wish 

to allocate a different Friendly Name which can be useful when connecting to multiple devices.  Once changes have been made 

click on 

Apply Settings 

to save.

If an input source is connected to the Fx4 but the actual signal fails, the Fx4 will try to connect to a valid signal by scanning the 
input connectors in the following order:

1 - DisplayPort

2 - HDMI 1

3 - HDMI 2

If no signal is detected on either of the three input connectors the Fx4 will display a pre-configured Datapath logo.  To upload 

your preferred logo (max 4k), click on the 

Upload Logo

 button in the 

Devices Tab 

and browse to upload your logo.  

  It can take up to 5 minutes to complete the upload

 

Full instructions on how to configure your Fx4 are available in the Wall Designer application help file.  

Содержание Fx4

Страница 1: ...Multi Display Controller USER GUIDE Version 1 0 0...

Страница 2: ...Panel 8 4 2 Rear Panel 8 4 3 Rack Mounting the Fx4 9 Chapter 5 Software 10 5 1 Wall Designer 10 5 2 Wall Designer Features 10 5 4 Running theWall Designer Application 11 Chapter 6 Cabling 13 6 1 Conne...

Страница 3: ...9 8 2 Technical Support 19 Chapter 9 Maintenance 20 9 1 Maintenance of the Fx4 20 Chapter 10 Environmental 21 10 1 Certification and Compliances 21 Chapter 11 Specifications 22 Chapter 12 Warranty RMA...

Страница 4: ...ions and pages are numbered individually Pages are numbered in Arabic numerals with the exception of the cover page no numbering 1 3 Fonts and Symbols 1 3 1 Fonts The font used throughout the user gui...

Страница 5: ...1 4 Working Environment The equipment should be located in an environment free from dust moisture and extreme changes in temperature and should be placed on a stable and solid work surface Liquids hot...

Страница 6: ...have an adverse affect on the operation of the system or could cause injury to the operator Should there be any physical damage to the power sockets or exposed wiring do not connect to a power source...

Страница 7: ...hernet loop through is supported on the second port meaning multiple devices can be connected 3 2 Features Each output monitor can take its input from any region of the input image as all of the requi...

Страница 8: ...inated the Input LED indicates a valid source is connected Status Continuous illumination Indicates the Fx4 is operating normally Flashing Unit is operating over the normal operating temperature Ensur...

Страница 9: ...e Fx4 in a daisy chain architecture using Ethernet cables Ethernet loop through is supported The LAN connector can also be used to connect the Fx4 to a PC for configuration USB The USB socket is used...

Страница 10: ...that users regularly visit the Datapath website for information on new software releases Insert the software CD into a CD DVD drive and the installation wizard should begin automatically Should the in...

Страница 11: ...wizard will continue installing the software 5 3 3 View Readme Click onView Readme to open an HTML document containing the latest information and bug fixes for the application TheWall Designer applica...

Страница 12: ...the outputs from the devices to specific monitors on the display wall For ease of useWall Designer has an automatic configuration feature Auto config which when clicked automatically adds the require...

Страница 13: ...on non lockable HDMI cables to ensure they remain firmly attached to the Fx4 Connecting HDMI Input Cable 6 3 Connecting Input Sources The Datapath Fx4 has three dedicated input connectors 2 x HDMI an...

Страница 14: ...p connector is used to connect two or more Fx4 s when the requirement is to create large video display walls with more than 4 monitors Using a DisplayPort cable not supplied connect the Out Loop from...

Страница 15: ...DisplayPort 7 1 2 Connecting Outputs Depending on the Fx4 model ordered either HDMI or DisplayPort cables are required not supplied The Fx4 has 5 output connectors 4 x monitor outputs and 1 x DisplayP...

Страница 16: ...ices window is where the input devices and monitors are linked to complete the design of the video wall this is done by allocating inputs to devices and the outputs from the devices to specific monito...

Страница 17: ...he device by right clicking then select Associate Device from the displayed menu a list of available Fx4 s is displayed Click on the virtual device to display its properties the Device Properties can...

Страница 18: ...the IP Address Subnet Mask and Gateway can be manually configured Dual Ethernet Ports Connect the Fx4 to a network using the top LAN connector then open Wall Designer and create your display layout as...

Страница 19: ...e visual representation of the Fx4 appears in the Device window a blue information icon will be displayed Click on the information icon for details of available upgrades 8 1 4 Intermittent or Loss of...

Страница 20: ...Your Fx4 requires little maintenance however care should be taken to keep all ventilation holes clear to allow an unrestricted flow of air through the unit Note Failure to keep ventilation holes clear...

Страница 21: ...ply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is oper...

Страница 22: ...up to 165 MP s DisplayPort Model 4 x DisplayPort 1 1 1080p 60 or equivalent up to 165MP s Loop through both models DisplayPort1 2 locked to selected video input resolution Input Surface 8k x 8k maximu...

Страница 23: ...ew or previously repaired product and returned to you at our cost b The product is out of warranty and is found to be faulty The product if possible will be repaired or replaced at fixed cost as state...

Страница 24: ...h Limited Whilst every effort is made to ensure that the information contained in this User Guide is correct Datapath Limited make no representations or warranties with respect to the contents thereof...

Страница 25: ...ensTurn Red 19 Disposal 21 F FCC Rules 21 Features 7 Firmware Support 22 Fonts and Symbols 4 G Gateway 18 Genlock Input 22 H HDMI Cable Lock 13 Help Files 12 High Bit Rate 14 I Initial Inspection 5 6...

Страница 26: ...c IP s 18 StorageTemperature 22 Subnet Mask 18 Switching On 15 Symbols 4 Sync 8 T Toolbar 11 12 U Unpacking 5 6 Upload Logo 17 User Manual 11 V Ventilation 5 Ventilation holes 20 Video Input Connectio...

Отзывы: