46
EMPTY
SENSOR
LEVEL
Establishes the threshold for the empty value (0 - 255), where 000 is the Default
Setting.
TRAN SENSOR
GAIN
Establishes the sensitivity of the transmissive sensor (0 - 31), where 15 is the
Default Setting.
REFL SENSOR
GAIN
Establishes the sensitivity of the reflective sensor (0 - 31), where 15 is the Default
Setting.
PRINTHEAD
CLEANING
Controls the automatic printhead cleaning alert and cleaning routine, where:
CLEAN HEAD
SCHEDULE
Specifies the inch (or centimeter) count at which the printer will prompt you to
clean the printhead. (Note that the specified count (0 - 200 inches) will be
multiplied by one thousand, while zero [the default value] will disable the cleaning
schedule function.) If the specified count is exceeded three times, a Head
Cleaning Fault will be initiated.
CLEAN HEAD
COUNTER
Indicates the number of inches (or centimeters) since a cleaning was last initiated.
RESET
COUNTER
Resets the Clean Head Counter to zero to restart the Clean Head Schedule.
CLEAN HEAD
NOW
Initiates the cleaning routine and resets the Clean Head Counter.