61
IMAGING
MODE
Determines the process used to format labels, a selection that can affect
throughput and the accuracy of time-stamping, where:
MULTIPLE
LABEL
Images multiple labels as memory permits, achieving the fastest throughput.
If time-stamping labels, however, the indicated time will reflect the moment
of imaging rather than the actual print time. (Default Setting)
SINGLE
LABEL
Images the next label only after the previous label has been successfully
printed, providing the most accurate time-stamping but slowing throughput.
PAUSE MODE
Allows for the controlled, user-interactive, printing of labels, where:
ENABLED
Requires the user to press the
PAUSE Key
to output each label.
DISABLED Labels
are
printed without pausing. (Default Setting)
PEEL MODE
Allows the printer to wait until the GPIO Start of Print signal is received (via
the optional GPIO Port) to feed a label, where:
ENABLED
Inhibits the feed function until the GPIO Start of Print signal is received.
DISABLED
Feeds the label regardless of the GPIO Start of Print signal. (Default Setting)
SECURITY
Allows all or part of the User Interface to be password-protected and for that
password to be modified:
SELECT
SECURITY
Allows a four-digit password to be set for specific User Interface areas,
where:
MENU AND
TEST
Sets a password requirement for all menu areas.
SECURE
MENU
Sets a password requirement for the User and Advanced menus.
DISABLED
No password is required for access. (Default Setting)
MODIFY
PASSWORD
Modifies the four-digit password required for User Interface access when
security is enabled. To modify the password, select each digit using the
UP
and
DOWN Buttons
, use the
RIGHT Button
to shift the cursor position, and
press the
ENTER Key
to input the code. You will be prompted to confirm the
new password by entering the same numeric code again. Afterward, exit the
menu and, at the SAVE CHANGES prompt, select YES to proceed with the
password (or NO to discard the changes).
Note:
To be activated, the password must initially be set to a value other than the default
setting (0000).
UNITS OF
MEASURE
Sets the measurement standard used in the printer's database, where:
IMPERIAL
Gives length and counter information in inches. (Default Setting)
METRIC
Gives length information in millimeters and counter information in
centimeters.
Содержание H Class
Страница 1: ...Operator s Manual ...
Страница 2: ......
Страница 6: ......
Страница 12: ...4 ...
Страница 23: ...15 Network Status page TCP IP Configuration page ...
Страница 42: ...34 ...
Страница 142: ...134 ...
Страница 144: ...136 ...
Страница 152: ...144 ...
Страница 156: ...148 ...
Страница 160: ...152 ...