H-Class
Advanced Entry Calibration (continued)
Step
Action
Displayed Message
Comment
J
Use the buttons to
increment the Gain
Number by one and then
press ENTER. Record the
TOF Value. Repeat this
process for each Gain
Number.
TRAN SENSOR GAIN
yyy (0 - 31)
01
These are TOF Values,
where “yyy” represents
the current sensor
reading.
Sample Calibration Table
Gain Number
Label Value
TOF Value
Difference Value
00 252 248
01 250 245
02 248 234
… … …
31 09 14
Step
Action
Displayed Message
Comment
K
In your sample calibration
table, where both the
Label Value and TOF Value
are at least 20, subtract
the amounts and record
the result as a Difference
Value (see below).
Identify the largest
Difference Value and the
corresponding Gain
Number. This Gain
Number will be used to
resample the media.
TRAN SENSOR GAIN
yyy (0 - 31)
31
In this example, Gain
Number 18 is chosen
because, where both
values are at least
twenty, it has the highest
Difference Value.
Sample Calibration Table
Gain Number
Label Value
TOF Value
Difference Value
00 252 248 4
01 250 245 5
02 248 234 14
… … … …
15 188 63 125
16 184 51 133
17 179 38 141
18
174
25
149
19 170 19 N/A
… … … …
31 132 14 N/A
Содержание H-4212
Страница 1: ...Operator s Manual ...
Страница 2: ......
Страница 6: ......
Страница 16: ...6 H Class ...
Страница 40: ...30 H Class ...
Страница 86: ...76 H Class ...
Страница 142: ...132 H Class ...
Страница 146: ...136 H Class ...
Страница 150: ...140 H Class ...
Страница 158: ...148 H Class ...
Страница 162: ...152 H Class ...
Страница 176: ...166 H Class ...
Страница 180: ......