The “RS-232 Setup” allows users to specify the properties of the serial connection.
The “Baud Rate” and “New Line” fields are implemented on the interface (PC or browser) as well as
on the reader.
The fields “Number of bits”, “Stop bits”, “Parity”, “Handshake” are implemented on the interface but
not yet on the reader. Changes done on these fields do not yet affect the system behaviour.
The “Remove Header” field informs the reader that expected responses must contain only essential
information (explanations, warnings and miscellaneous information must be cut off).
The “Continuous” field enables/disables the continuous-reading mode. If this property is enabled,
inventory-cycles are automatically repeated otherwise only one cycle is done.
The “Stand Alone” field has following meanings:
Stand Alone Mode Disabled
: after the reader has been turned on, it waits for the start-reading
command to come. Until this moment, it remains in a not-reading state.
Stand Alone Mode Enabled (Detect)
: at power on the reader starts reading automatically and sends
the found UIDs after each inventory cycle.
The “Inter Code Delay” field specifies how much time (in sec/100) must be awaited between the
sending of two subsequent UIDs.
The “Code Length” field specifies the length and format of the sent UIDs.
5.7
R
EADER
S
ETUP
The “ReaderSetup” tab allows users to specify overall properties of the reader.
It is possible to specify:
the antenna power:
•
0 mW – 12 000 mW
(1000 mW = 1 W; 2000 mW = 2 W; etc. )
the technologies of the transponders being used:
•
ISO-15693
•
I-Code I
ARM: 4.0.0 / DSP 2.1.4
Type: MC