110
T11:<message>
Less important warning or message. The serialization will not be
interrupted.
Flowchart of device programming with custom-generator serialization
When Custom-generator serialization is used, it means, that before each device programming
is started, serialization engine calls serialization generator executable, to
generate serial .dat file. PG4UW serialization engine manages proper
command line parameters for calling of serialization generator. The data
from .dat file are immediately read to internal programmer buffer and used
as data for programming device. Also next serial number information
(record T02) is remembered in PG4UW.
Typical flowchart of device programming is following:
1. Start of programming batch
2. Device insertion test
3. Serialization sequence, consists from four steps:
call of serialization generator with proper command line parameters to generate
serialization .dat file
waiting for serialization .dat file to be available
reading of serialization .dat file data to programmer buffer (the data will be used for
programming device)
delete serialization .dat file after reading of data from it
4. Device programming
5. Device verification
6. Operation result check.
This is fully managed by PG4UW control program. Serialization generator does not
have to do any operation according to operation result. Control program will call
serialization generator with required command line parameters.
OK
- PG4UW makes request for next serial number. Next serial number was read from
.dat file in step 3. Call of serialization generator will have next serial number specified in
command line.
ERROR
- PG4UW does not make request for new serial number. Recent serial number
will be used for next device. Next call of serialization generator will have recent serial
number specified in command line.
7. Repeat programming with next device?
Yes
goto step 2.
No
continue at step 8.
8. End of programming batch
Notes:
In case of error programming result, recent serial number is used, but generator will be
called at step 3. anyway, even if the same number is used as for previously
programmed device.
If error of serialization .dat file is detected, program PG4UW reports serialization error
and stops continuing of programming batch immediately.
Device / Device options / Statistics
Statistics gives the information about actual count of device operations, which were
proceeded on selected type device. If one device is corresponding to one device operation,
e.g. programming, the number of device operations will be equal to number of programmed
devices.
Содержание Dataman-40Pro
Страница 7: ...Quick Start 7 Introduction ...
Страница 12: ...12 Quick Start ...
Страница 14: ...14 4 check if the device is blank click on 5 program device click on 6 additional verify of device click on ...
Страница 15: ...Detailed description 15 Detailed description ...
Страница 16: ...16 DATAMAN 448PRO2 ...
Страница 30: ...30 DATAMAN 48PRO2 DATAMAN 48PRO2C ...
Страница 45: ...DATAMAN 40PRO 45 DATAMAN 40PRO ...
Страница 54: ...54 DATAMAN MEMPRO ...
Страница 61: ...Setup 61 Setup ...
Страница 65: ...Setup 65 Step 6 Check your setting and then click on Install button Step 7 Installation process will start ...
Страница 70: ...70 Step 6 Click on Continue Anyway button For Windows Vista Click Install this driver software anyway ...
Страница 72: ...72 PG4UW ...
Страница 141: ...PG4UWMC 141 PG4UWMC ...
Страница 154: ...154 Installation procedure customized ...
Страница 159: ...Common notes 159 Common notes ...
Страница 171: ...Troubleshooting and warranty 171 Troubleshooting and warranty ...