background image

XRF410N™ INSTALLATION 

 

 

 

The following table summarizes the main characteristics of the various models: 
 

Model 

XRF410N 

1D Code 

Resolution  

Pitch  
[mm] 

Lighting 

System 

Reading 

Distance 

[mm] 

DOF 

[mm] 

Focus 

Dist. 

[mm] 

PPI 

FOV 
min. 

[mm] 

Overlap 

min 

between 

readers 

[mm] 

Others 

BP- B0x 

Medium Res 

0.38mm 
(15mils) 

 

235 

LT-10 

1270-

1670 

400 

1570 

91 

590 

120 

Cropped 

Image:  

1600x780 

BP- B1x 

High Res 

0.33mm 
(13mils) 

175 

LT-10 

1050-

1450 

400 

1300 

111 

470 

120 

 

Cropped 

Image 

1600x780 

HP- H0x 

Medium Res 

0.38mm 
(15mils) 

 

235 

LT-20 

1270-

1670 

400 

1570 

91 

590 

120 

Full 

image & 

Packtrack 

HP- H1x 

High Res 

0.33mm 
(13mils) 

175 

LT-20 

1050-

1450 

400 

1300 

111 

470 

120 

Full 

image & 

Packtrack 

HP- H2x 

Very High 

Res 

0.25mm 
(10mils) 

155 

LT-20 

860-1110 

250 

960 

147 

395 

85 

Full 

image & 

Packtrack 

Table 1 

– Main Characteristics 

 
In order to create multi-side or multi-point reading stations, the product line further includes 
the following models: 
 

XRF410N-xx0  MASTER

: made up of two readers: one Master and one Slave 1. The 

Master must be connected directly to a 

CBX

 connection box through a 

CAB-DS-xx-S

 

cable. The Slave is already connected to a QL100 which is provided with a CBL-1490 
ID-NET  network  terminator.  The  other  end  of  the  QL100  must  be  connected  to  the 
CBX using a 

CBL-1480-xx

 cable to complete the ID-NET network. 

 

XRF410N-xx1  EXTENSION

:  made  up  of  two  Slave  readers  each  connected  to  a 

QL100. These models must be connected to a 

Master XRF410N

 through the ID-NET 

network using a 

CBL-1480-xx

 cable to complete the ID-NET network. 

One or more Extension XRF410N models can be chained together to extend the ID-
NET  network.  When  using  the  Extension  models,  the  CBL-1490  ID-NET  network 
terminator (present on the QL100 of the Slave reader on the Master XRF410N) must 
be transferred to the last slave on the last Extension XRF410N in the network. 

 
 
 

 

Содержание XRF410N Series

Страница 1: ...History Issue Date Paragraph Change Rev 0 February 13 2015 First Release Rev A March 24 2015 Added baud rate note Rev B June 9 2015 Added Electrical connection diagrams and power supply table Rev C Ap...

Страница 2: ...be used within an ID NET network in which at least one other reader is present They cannot be used as Stand Alone devices The various XRF410N models do not include CBX connection boxes or CBX connecti...

Страница 3: ...or multi point reading stations the product line further includes the following models XRF410N xx0 MASTER made up of two readers one Master and one Slave 1 The Master must be connected directly to a C...

Страница 4: ...s Required Accessories for XRF410N Base Performance Models Description 1 Module 2 Modules 4 Modules Part Number XRF410N B00 2HD_MED RES_MASTER 1 1 1 937400028 XRF410N B01 2HD_MED RES_EXTENSION 1 3 937...

Страница 5: ...EP 593 PHOTOCELL KIT 1 1 1 93ACC1791 OEK 2 OPTICAL ENCODER CAB 10M SPRING 1 1 1 93ACC1770 BA400 M12 3P M PANEL CONN EXT POWER 1 93ACC1853 CAB PG 0002 VDC PWR PG120 IDNET 2M 1 93ACC1870 PG 120 K01 PWR...

Страница 6: ...network 3 Run DL CODE and connect to the Master reader 4 Run New Configuration Multi Device This will assign ID NET addresses to all the Slaves in the network associating them with their respective s...

Страница 7: ...front mounting bolt so that the XRF410N rests on the positioning bracket This allows positioning to be done without having to physically support the weight of the XRF410N Figure 2 XRF410N Mounting to...

Страница 8: ...mage acquisition overlapping Figure 3 Maintaining Pitch Between Multiple Modules Example Mounting Distance for XRF410N B0x Models Figure 4 Example Reading Distance Reference DOF and Minimum Reading Di...

Страница 9: ...mirror alignment however many variations can be constructed NOTE For all of the following mounting examples the positioning distances are not given since they depend on the application and characteris...

Страница 10: ...one bolt in the center position and one bolt in the outer ring 2 Rotate the mirror brackets so that the 15 skew angle slot is aligned with the profile channel see the figure below 3 Mount the XRF410N...

Страница 11: ...ion Mirror 1 Mount and center the ST 344 brackets on the vertical profile 2 Mount the mirror brackets to the ST 344 brackets with one bolt in the center position and one bolt in the outer ring 3 Rotat...

Страница 12: ...Module Electrical Connections Figure 7 Bxx Single Module Electrical Connections back view Ethernet Host Power CBX500 ATS XRF410N Master P S CBL 1480 05 ID NET Terminator CAB DS05 S CBL 1480 05 ID NET...

Страница 13: ...ions Figure 9 Bxx Multiple Module Electrical Connections back view Ethernet Host Power CBX500 ATS XRF410N Master XRF410N Extension XRF410N Extension P S CAB DS05 S CBL 1480 05 ID NET Terminator CBL 14...

Страница 14: ...ination Power cable is connected directly to the power supply Connect the White wire to Vdc and Blue wire to GND Connect the cable shield to Earth ground Ethernet Host Power CBX500 ATS XRF410N Master...

Страница 15: ...nected directly to the power supply Connect the White wire to Vdc and Blue wire to GND Connect the cable shield to Earth ground Ethernet Host Power CBX500 ATS XRF410N Master XRF410N Extension XRF410N...

Страница 16: ...to Vdc and Blue wire to GND Connect the cable shield to Earth ground CBX500 ATS XRF410N Master XRF410N Extensions XRF410N Extension P S CAB DS05 S CBL 1480 05 ID NET Terminator CAB MLP 05 XRF410N Exte...

Страница 17: ...ut 1 The following table shows the Image Setup photometric parameters settings to use for each model based on the reference application conveyor speed and code resolution The Image Setup parameters ca...

Страница 18: ...l analysis of decoding times measured on a variety of packs considered typical in various T L applications Decoding Timeout depends heavily on the type of acquired images As a general rule it is sugge...

Страница 19: ...have the same requirements and considerations as mentioned above for Phase Mode They also require an Encoder to register line speed conveyor In addition the PackTrack calibration procedure must be exe...