XRF410N™ INSTALLATION
3
The following table summarizes the main characteristics of the various models:
Model
XRF410N
1D Code
Resolution
Pitch
[mm]
Lighting
System
Reading
Distance
[mm]
DOF
[mm]
Focus
Dist.
[mm]
PPI
FOV
min.
[mm]
Overlap
min
between
readers
[mm]
Others
BP- B0x
Medium Res
0.38mm
(15mils)
235
LT-10
1270-
1670
400
1570
91
590
120
Cropped
Image:
1600x780
BP- B1x
High Res
0.33mm
(13mils)
175
LT-10
1050-
1450
400
1300
111
470
120
Cropped
Image
1600x780
HP- H0x
Medium Res
0.38mm
(15mils)
235
LT-20
1270-
1670
400
1570
91
590
120
Full
image &
Packtrack
HP- H1x
High Res
0.33mm
(13mils)
175
LT-20
1050-
1450
400
1300
111
470
120
Full
image &
Packtrack
HP- H2x
Very High
Res
0.25mm
(10mils)
155
LT-20
860-1110
250
960
147
395
85
Full
image &
Packtrack
Table 1
– Main Characteristics
In order to create multi-side or multi-point reading stations, the product line further includes
the following models:
-
XRF410N-xx0 MASTER
: made up of two readers: one Master and one Slave 1. The
Master must be connected directly to a
CBX
connection box through a
CAB-DS-xx-S
cable. The Slave is already connected to a QL100 which is provided with a CBL-1490
ID-NET network terminator. The other end of the QL100 must be connected to the
CBX using a
CBL-1480-xx
cable to complete the ID-NET network.
-
XRF410N-xx1 EXTENSION
: made up of two Slave readers each connected to a
QL100. These models must be connected to a
Master XRF410N
through the ID-NET
network using a
CBL-1480-xx
cable to complete the ID-NET network.
One or more Extension XRF410N models can be chained together to extend the ID-
NET network. When using the Extension models, the CBL-1490 ID-NET network
terminator (present on the QL100 of the Slave reader on the Master XRF410N) must
be transferred to the last slave on the last Extension XRF410N in the network.