![Datalogic XRF410N Series Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/datalogic/xrf410n-series/xrf410n-series_application-note_3712645011.webp)
XRF410N™ INSTALLATION
11
EMK-600 Side Mount - Alternative
An alternative mounting solution is to use the ST-344 Bracket. XRF410N and EMK-600
Mirror alignment is obtained when the EMK is centered to the frame profiles as shown in the
figures below. This bracket also provides the freedom of applying offsets to the mirror where
necessary.
NOTE:
The ST-344 Bracket is an accessory for the EMK-600 Deflection
Mirror.
1. Mount and center the ST-344 brackets on the vertical
profile.
2. Mount the mirror brackets to the ST-344 brackets with
one bolt in the center position and one bolt in the outer
ring.
3. Rotate the mirror brackets so that the 15° skew angle
slot is aligned with the profile channel, (see the figure
below).
4. Mount
the
XRF410N
assembly
bracket to the profile using the
through-holes (not the slots).
5. Move the mirror assembly to the correct
distance from the reader according to your
application.
6. Position the XRF410N assembly vertically to center it on the
mirror.
7. Tighten the bolts.
15° Skew