Instruction Manual
38
7.2. Diagnostic
messages
The operator is able to check the main causes of the system stop and failure, using the same LEDs
used for visualising the functions.
For Receiver:
Function
Status
Meaning
LED DIGIT
Alignment See
chapter.5
TEST
(red ON)
Light curtain being tested, the OSSD status must
be OFF
Emission
(OSSD ON)
(green ON)
Light curtain working and in normal operation
conditions
Interruption
(OSSD OFF)
(red ON)
Light curtain working and in safety block
conditions.
Interlock
Beams free
(red ON
yellow ON)
Interlock curtain waiting for restart. OSSD status
must be OFF
Interlock
Beams
interrupted
(red ON
yellow ON)
Light curtain interlocked, OSSD status must be
OFF
Signal level
Minimum (1
bar)
Medium (2
bar)
Maximum (3
bar)
Normal
operation
EDM enabled
EDM function is selected
Function
Type
Check and repair
LED DIGIT
OSSD error
(red ON)
Check OSSD connections. Make sure that they
are not in contact with one another or with the
supply cables, then Reset. If the failure continues
contact DATALOGIC AUTOMATION
Internal error
(red ON)
Switch OFF and switch ON the power supply
circuit. If the failure continues contact
DATALOGIC AUTOMATION
Optical error
(red ON)
Reset. If the failure continues contact
DATALOGIC AUTOMATION
EDM error
(red ON)
Check EDM connections and lines. If the failure
continues contact DATALOGIC AUTOMATION
Error
status
Restart selection
error
(red ON)
Check the man/auto restart connection. If the
failure continues contact DATALOGIC
AUTOMATION