SG2 EXTENDED
Instruction Manual
44
10. TECHNICAL DATA
ELECTRICAL DATA
Power supply (Vdd):
24 Vdc
20
Consumption (TX):
2 W max
Consumption (RX):
3.5 W max (without load)
Outputs:
2 PNP
Short-circuit protection:
1.4 A max
Output current:
0.5 A max / each output
Output voltage – status ON:
Vdd –1 V min
Output voltage – status OFF
0.2 V max
Capacitive load:
2.2 uF @ 24Vdc max
Response times:
See chapter 11
Protected height:
150..1800mm
Safety category:
Type 2
Auxiliary functions:
Reset / Test / EDM / Range selection and manual /
Automatic Restart
Electrical protection:
Class I / Class III
(see sect.4.2)
Connections:
M12 4 poles for emitter
M12 8 poles for receiver
Cables length (for power supply): 50 m. max
OPTICAL DATA
Emitting light (
):
Infrared, LED (950 nm)
Resolution:
30 - 50 - 90 mm
Operating distance:
0.2…19 m
Ambient light rejection:
IEC-61496-2
MECHANICAL AND ENVIRONMENTAL DATA
Operating temperature:
0…+ 55 °C
Storage temperature:
-25…+ 70 °C
Humidity:
15…95 % (no condensation)
Mechanical protection:
IP 65 (EN 60529)
Vibrations:
Width 0.35 mm,
Frequency 10 … 55 Hz
20 sweep per axis, 1octave/min (EN 60068-2-6)
Shock resistance:
16 ms (10 G) 1,000 shocks per axis
(EN 60068-2-29)
Housing material:
Painted aluminium (yellow RAL 1003)
Front side material:
PMMA
Caps material:
PC MAKROLON
Weight:
1,3 kg per linear metre