1D Symbologies
Enter/Exit Programming Mode
Product Reference Guide
123
Code 128 Set Length 1
Specifies one of the bar code lengths for
Code 128 Length Control on page 122
. Length 1 is the
minimum label length if in
Mode, or the first fixed length if in
Mode. Length includes the bar code’s data characters only. The
length can be set from 1 to 80 characters.
provides some examples for setting Length 1. See
for detailed instructions on
setting this feature.
Table 5. Code 128 Length 1 Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
01 Character
07 Characters
15 Characters
80 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODE 128 LENGTH 1 SETTING
4
Scan Two Characters From
‘0’ and ‘1’
‘0’ and ‘7’
‘1’ and ‘5’
‘8’ AND ‘0’
5
Scan ENTER/EXIT PROGRAMMING MODE
$CC8L1
Select Code 128 Set Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
01 = Length 1 is 1 Character
Содержание QuickScan QD24 series
Страница 36: ...Enter Exit Programming Mode Global Interface Features 26 QuickScan I QD24XX QBT24XX QM24XX NOTES...
Страница 188: ...Enter Exit Programming Mode Plessey 178 QuickScan I QD24XX QBT24XX QM24XX NOTES...
Страница 220: ...Symbology Selection 210 QuickScan I QD24XX QBT24XX QM24XX NOTES...
Страница 302: ...Keypad 292 QuickScan I QD24XX QBT24XX QM24XX A B C D E F...
Страница 312: ...Scancode Tables 302 QuickScan I QD24XX QBT24XX QM24XX NOTES...