ETHERNET/IP™: Industrial Protocol
32
BC9180™ Base Station/Charger
Identity Object (01
HEX -
1 Instance)
The following tables contain the attribute, status, and common services
information for the Identity Object.
Table 4.Identity Object (01
HEX -
1 Instance)
Instance
Attribute
ID
Name
CIP
Data Type
Data
Value
Access
Rule
Class
(Instance
0)
1
Revision
UINT
1
Get
Instance 1 1
Vendor number
UINT
850
Get
2
Device type
UINT
43
Get
3
Product code number
UINT
9500
Get
4
Product major revision
Product minor revision
USINT
USINT
1.01
Get
5
Status
WORD
See
Get
6
Serial number
UDINT
Unique 32 bit value
(Last 4 of MAC ID)
Get
7
Product name
SHORT
STRING32 Wireless Barcode
Reader
Get
100
Product model number SHORT
STRING32
“Product Model
Number”
Get
Table 5. Identity Object’s common services
Service code
Implemented for
Service name
Class level
Instance level
05
Hex
No
Yes
Reset
0E
Hex
Yes
Yes
Get_Attribute_Single
10
Hex
No
Yes
Set_Attribute_Single
Message Router Object (02HEX - 1 Instance)
***No supported services or attributes***
Содержание PowerScan PBT9500
Страница 1: ...BC9180 Software Reference Guide Base Station Charger Ethernet Base...
Страница 4: ...ii BC9180 Base Station Charger NOTES...
Страница 8: ...Introduction 4 BC9180 Base Station Charger NOTES...
Страница 12: ...Setup 8 BC9180 Base Station Charger NOTES...
Страница 18: ...Ethernet Host Interface Operation 14 BC9180 Base Station Charger NOTES...
Страница 50: ...ETHERNET IP Industrial Protocol 46 BC9180 Base Station Charger NOTES...
Страница 52: ...Standard Defaults 48 BC9180 Base Station Charger NOTES...