Good Read LED Duration
This feature specifies the amount of time that the Good Read LED remains
on following a good read. The good read LED on time can be set within a
range of 100 milliseconds to 25,500 milliseconds (0.1 to 25.5 seconds) in
100ms increments. A setting of 00 keeps the LED on until the next trigger
pull.
See
in “References” for detailed instructions and examples for set-
ting this feature.
Good Read LED Duration Setting =
Keep LED on until next trigger pull
Select Good Read LED Duration Setting
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in
repre-
senting your desired character(s). End by scanning
the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
DEFAULT
003 = Good Read LED
stays on for 300 ms.
Indicators are dimmed during sleep.
Содержание PowerScan 950X Series
Страница 30: ...Setup 20 PowerScan PD953X PBT950X PM950X NOTES...
Страница 34: ...Configuration Using Bar Codes 24 PowerScan PD953X PBT950X PM950X NOTES...
Страница 56: ...46 PowerScan PD953X PBT950X PM950X NOTES...
Страница 72: ...62 PowerScan PD953X PBT950X PM950X NOTES...
Страница 90: ...Enter Exit Programming Mode 80 PowerScan PD953X PBT950X PM950X NOTES...
Страница 182: ...172 PowerScan PD953X PBT950X PM950X NOTES...
Страница 278: ...268 PowerScan PD953X PBT950X PM950X NOTES...
Страница 316: ...References 306 PowerScan PD953X PBT950X PM950X NOTES...
Страница 320: ...Message Formatting 310 PowerScan PD953X PBT950X PM950X NOTES...
Страница 358: ...Scancode Tables 348 PowerScan PD953X PBT950X PM950X NOTES...