Enter/Exit Programming Mode
Product Reference Guide
161
Code 93 Set Length 1
Specifies one of the bar code lengths for
. Length 1
is the minimum label length if in
Mode, or the first fixed
length if in
Mode. Length includes the bar code’s data charac-
ters only. The length can be set from 01 to 50 characters.
provides some examples for setting Length 1. See
detailed instructions on setting this feature.
Table 20. Code 93 Length 1 Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
01 Characters
07 Characters
15 Characters
50 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODE 93 LENGTH 1 SETTING
4
Scan Two Characters From
‘0’ and ‘1’
‘0’ and ‘7’
‘1’ and ‘5’
‘5’ AND ‘0’
5
Scan ENTER/EXIT PROGRAMMING MODE
$CC9L1
Select Code 93 Set Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
~
CANCEL
DEFAULT
01 = Length 1 is 1 Character
Содержание PowerScan 950X Series
Страница 30: ...Setup 20 PowerScan PD953X PBT950X PM950X NOTES...
Страница 34: ...Configuration Using Bar Codes 24 PowerScan PD953X PBT950X PM950X NOTES...
Страница 56: ...46 PowerScan PD953X PBT950X PM950X NOTES...
Страница 72: ...62 PowerScan PD953X PBT950X PM950X NOTES...
Страница 90: ...Enter Exit Programming Mode 80 PowerScan PD953X PBT950X PM950X NOTES...
Страница 182: ...172 PowerScan PD953X PBT950X PM950X NOTES...
Страница 278: ...268 PowerScan PD953X PBT950X PM950X NOTES...
Страница 316: ...References 306 PowerScan PD953X PBT950X PM950X NOTES...
Страница 320: ...Message Formatting 310 PowerScan PD953X PBT950X PM950X NOTES...
Страница 358: ...Scancode Tables 348 PowerScan PD953X PBT950X PM950X NOTES...