All 1660 BT CCD scanners supplied by Dataman Barcode Systems have already been tested 
and configured to communicate with the accompanying Cipher 3610 USB Transponder. This 
means  the  1660  BT  DOES  NOT  require  any  further  initial  programming  and  can  be  used 
immediately, these configuration instructions are for reference purposes. 
 
The  A4  sheets  of  command  and  control  bar  codes  that  are  included  with  these  instructions 
should  be  studied  and  will  be  required  during  the  batch  data  download  operations,  we 
recommend that a copy be made and laminated to provide greater durability, the original to be 
filed for reference. The Bar-Key.exe command charts can to be folded and laminated as A5.   
 
The Cipher 1660 BT will require batteries to be fitted. If you have not already done so, please 
undertake the procedures described as follows. 
 
Use only Alkaline or NiMh rechargeable 

AAA

 batteries in your scanner (Do not use NiCad).

 

Please remove the batteries when you store your scanner for more than 30 days 

 

1. Press the battery cover release button, then slide and lift the battery cover. 
2. Insert the batteries noting polarity. 2 x heavy-duty 

AAA

 batteries are required. 

3. To replace the battery cover, make sure that the cover tabs fit into the cover slots, and then 
slide the cover until it clicks into place. 
 
 
 
 
 
 
 
 
With the use of the supplied command bar codes the  1660 BT  should be configured for the 
type  of  batteries  being  used  (Alkaline  or  NiMh),  setting  the  1660  BT  for  the  specific  battery 
type ensures the correct low battery power alarm settings are maintained.  
 
During  normal  operation  the  scanner  can  work  for  over  30  hours  or  approximately  28,000 
scans, for intensive data collection operations ensure spare batteries are on hand. 
 
Initially the 1660 BT scanner will be configured to communicate directly and immediately with 
the computer using the Cipher 3610 USB Bluetooth transponder. 
 

Note:

 The  Cipher  3610  USB  Bluetooth  transponder  is  connected  to  a vacant  USB  port  on 

the computer and sends the bar code data received from the 1660 directly to the computer’s 
keyboard buffer so it appears as if it was typed from the keyboard.  
 
 

 
 
 
 
 
 
 
 
 
 

Operating the Cipher 1660 BT scanner… 

 
Turn ON the scanner… 

 

Press and hold the Power/Delete key for 3 seconds. The scanner will respond with a long 
beep (high tone), the LED indicator will illuminate solid red for a brief period of time. 

 

Turn OFF the scanner… 

 

Press  and  hold  the  Power/Delete  key  until  the  scanner  responds  initially  with  two  short 
beeps (high tone) and the LED illuminates red continually, the key can then be released. 

Power/Delete Key 

Scan Key 

Содержание Cipher 1660 BT Portable

Страница 1: ...replace the battery cover make sure that the cover tabs fit into the cover slots and then slide the cover until it clicks into place With the use of the supplied command bar codes the 1660 BT should be configured for the type of batteries being used Alkaline or NiMh setting the 1660 BT for the specific battery type ensures the correct low battery power alarm settings are maintained During normal o...

Страница 2: ...her cover unwanted barcode while scanning The bar code reader is now ready to use simply open the application that you require to capture the bar code data and start scanning For Windows users an ideal application to test the scanner is Notepad a small editor program located among Windows accessories How to scan with the Cipher 1660 BT Scanner Hold the 1660 Scanner at an angle to the bar code appr...

Страница 3: ...he 256 Kb non volatile flash memory is capable of securely storing in excess of 16000 13 digit EAN 13 sized bar codes data in the 256 Kb non volatile flash memory is NOT lost if the scanner is turned off or the battery power becomes low LED INDICATOR The triple colour LED on top of the scanner is used to provide user feedback For example the LED becomes solid red and goes off quickly when powering...

Страница 4: ...of range or suspended AUTO POWER OFF By default the Cipher 1660 BT is set to automatically power off after 10 minutes of non use this feature is intended to preserve battery life In cases where this time out period needs to be changed or is not desired it can be user programmed to another time period or disabled altogether The rapidly flashing blue light on the 3610 transponder unit indicates an a...

Страница 5: ...emote collection batch mode The accompanying A4 Dataman bar code command chart left has been provided to assist in this operation The bar code command chart is laid out in three distinct sections Set for Remote Data Collection Mode Set for Normal Operation and Steps for Downloading Data to the Server The chart contains certain instructions and comments on usage all operations should commence by sc...

Страница 6: ...elay has been set the actual stored data can be downloaded to the server the targeted computer program should be prepared to receive the data In a similar fashion to the download delay instruction described above the data is downloaded by firstly scanning the command bar code Begin Instruction Mode followed by the command bar code Transmit Stored Data followed by the Finish Instruction Mode comman...

Страница 7: ... titled Set for Normal Operation Scan each bar code 1 2 3 4 5 in this order These instructions and the accompanying bar code command chart have been created by Dataman Barcode Systems and are copyright Copies available from the Dataman web site Dataman Barcode Systems P O Box 855 Happy Valley Tel 088 322 7675 International Tel 618 8322 7675 S A 5159 Australia Fax 088 322 7288 International Fax 618...

Страница 8: ... to disengage the Auto Power Off mode or set the period to 30 Minutes Usage and experience in the field has shown that this Auto Power Off feature is not always convenient for library usage It is however crucial that this sequence of barcodes are read AFTER reading the barcodes in column 1 and not before if this order of reading is not followed it will result in the shut down period defaulting to ...

Страница 9: ... 5 Finish Instruction Mode 6 4 Set for Normal Operation Clear stored data if downloading has been completed successfully DaTaMaN Barcode Systems Tel 088 322 7675 Fax 088 322 7288 P O Box 855 Happy Valley S A 5159 www datamanbarcode com au Note When set for remote data collection mode the blue flashing light on the USB transponder will revert to a slow flash this is normal While in remote data coll...

Отзывы: