background image

 

1

 

Summary of Contents for SC5-USB-W

Page 1: ...1 ...

Page 2: ...dware warranty if any is 3 times the original purchase price of the product excluding any tax shipping and additional charges at the time of purchase from IDAutomation or the authorized affiliate or reseller This amount should be adequate to redirect any claims to the proper manufacturer however it should be understood that all intellectual property claims and all other claims relating to the hard...

Page 3: ...INESS OR GOODWILL LOSS OF DATA LOSS OF OPPORTUNITIES OR LOSS OF USE OF THE PRODUCT OR ANY EQUIPMENT COST OF CAPITAL COST OF SUBSTITUTE OR REPLACEMENT PRODUCT EQUIPMENT FACILITIES OR SERVICES DOWN TIME YOUR TIME REGARDLESS OF THE FORM OF ACTION ANY THIRD PARTY CLAIMS AND ANY INJURY TO PROPERTY OR BODILY INJURY INCLUDING DEATH TO ANY PERSON ARISING FROM OR RELATING TO THE USE OF OR THE INABILITY TO ...

Page 4: ...BREACH OF CONTRACT NEGLIGENCE TORT OR STRICT LIABILITY WHETHER OR NOT SUCH LOSS OR DAMAGE WAS FORESEEABLE EVEN IF WE OR ANY OF OUR AFFILIATED COMPANIES HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES ...

Page 5: ...g of the software is prohibited Due to continued product development this information may change without notice The information and intellectual property contained herein is confidential between IDAUTOMATION and the client and remains the exclusive property of IDAUTOMATION INC If you find any problems in the documentation please report them to us in writing IDAUTOMATION does not warrant that this ...

Page 6: ... in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of IDAUTOMATION INC For product consultancy and technical support contact IDAutomation com ...

Page 7: ...rough the notch 4 Connect the I F cable to the host computer communication port 5 Connect the AC adapter to the wall outlet 6 Place the imager in the cradle and verify the charge LED is flashing Charge the battery for at least 8 hours before the first use 7 To verify operation please link the imager with cradle first Refer to Wireless Connection in page 12 Point the imager at the barcode and pull ...

Page 8: ...get Bluetooth device Cradle Dongle connection auto detection The imager can be linked to either a cradle or other Bluetooth enabled devices Set PIN code to 0000 2 After well connecting Bluetooth dongle to PC find the blue tooth sign on Taskbar double click on it to bring out the Bluetooth Devices prompt After well connecting USB dongle to PC find the blue tooth sign on Taskbar double click on it t...

Page 9: ...9 Within the prompt click Add 3 Check the option My device is set up and ready to be found and click Next ...

Page 10: ...10 4 Select SC5 USB W among the Bluetooth devices found click Next 5 Select Don t use a passkey and click Next The Bluetooth connection will start to install the Bluetooth device for SC5 USB W ...

Page 11: ...s assigned The following example lists COM23 as the Outgoing port and COM24 as Incoming port your actual COM ports will depend on what s assigned on your PC Click Finish 7 Open HyperTerminal Set COM1 s Baud Rate as 9600 to communicate with SC5 USB W whose default baud rate is 9600 ...

Page 12: ...12 ...

Page 13: ...13 8 Select COM23 depending on your Outgoing COM port to connect Click OK 9 Click on Dial ...

Page 14: ...luetooth sign on taskbar After clicking on it the wizard will prompt as below enter 0000 SC5 USB W default PIN code within the Passkey field click Next Now the installation and setups have been completed you may start to scan barcodes to transmit data to HyperTerminal on PC ...

Page 15: ...e to the barcode so that the light reflected off the barcode can be seen by the imager Do not hold the imager perpendicular to the barcode 2 The scan line must cross the entire barcode The imager can not read the barcode data without seeing the entire barcode ...

Page 16: ...y and the external power supply has failed the imager will not operate Change the power supply with a known good power supply and reset the imager 2 Verify the interface cable is securely connected to the host computer Consult your technical support personnel or refer to your host system manual to verify the proper connection for the imager ...

Page 17: ... sufficient quality to be recognized by the imager Wrinkled smudged or torn labels will cause the imager to not read at all Scan a known good label to check the imager s read operation 5 Ensure that the cradle s interface type is compatible with the host computer by consulting your host system manual ...

Page 18: ...bel on the bottom of the cradle with the imager The imager will sound a good read beep and the LED will flash amber 4 Re place the imager in the cradle to continue the charge Once an imager is linked to a cradle they will remain linked until specific action is taken to unlink them see Unlinking They will remain linked if the cradle is unplugged if the battery is removed from the imager or if the e...

Page 19: ...an the Link Label and put on the original cradle If the cradle is linked with an imager and the original pair was stopped by out of range of the cradle or out of battery of the imager scan the link label of the cradle with a new imager and then put on the cradle the cradle will drop the original pair and establish a new link with the new imager 3 Scan the Link Label on an alternate cradle Scanning...

Page 20: ...es If the button is pushed while the imager is out of range the cradle will unlink and make itself available to other imagers The scanner will not drop its link with the cradle automatically but can be linked to any other cradle by reading its link label Note If just push the button with a short time less than one second a Paging feature will be performed to page the imager which was linked with t...

Page 21: ...n particular Deep Sleep Mode settings can impact battery life When the imager is placed in the cradle the battery will automatically charge While charging is taking place the charging LED marked with a battery symbol will blink green When the battery is fully charged the charging LED will stay on a solid green If there is an error in charging either with a failure in the charging circuit or with a...

Page 22: ...ced please follow the procedures below 1 Loosen the screw at the bottom of the imager 2 Take off the battery cover out of the imager 5 Use a new battery pack and replace the used one 3 Disconnect the battery cable connector from the main board 4 Remove the used battery from the battery container ...

Page 23: ... replacing the battery Improper operation may damage the imager 6 Place the new battery into the battery container 7 Connect the battery cable connector to the main board 8 Put the battery cover back to the imager handle 9 Fasten the screw to the imager ...

Page 24: ...e are linked together the imager will read and decode barcodes and transmit them via a Wireless radio to the cradle The cradle will then transmit the barcode data to the host computer over the host cable The host interfaces available from the cradle are RS 232 Keyboard wedge and USB as a normal corded imager ...

Page 25: ...uration If the units are linked any changes made to the cradle s configuration through the scan utility software will automatically be sent to the imager at the completion of the programming session By the same token any changes made to the linked imager s configuration will be transmitted to the cradle at the end of the programming session The following options are available for Auto Update Enabl...

Page 26: ...26 Enable firmware auto update only Allows only firmware updating Disable auto update No automatic updates will be performed 1BA02 1BA03 ...

Page 27: ...Default Duration 10 minutes Force imager into deep sleep mode if there is no barcode read in 10 minutes Duration 30 minutes Force imager into deep sleep mode if there is no barcode read in 30 minutes Duration 60 minutes Force imager into deep sleep mode if there is no barcode read in 60 minutes Duration 90 minutes Force imager into deep sleep mode if there is no barcode read in 90 minutes 7AJ00 7A...

Page 28: ...code to 0000 assigned to the target Bluetooth device In this case the PIN code of the Bluetooth enabled device should be set to 0000 to be identical with your imager Cradle connection only The imager can be used only with cradle Default Cradle Dongle connection auto detection The imager can be linked to either a cradle or other Bluetooth enabled devices Set PIN code to 0000 Note The imager only su...

Page 29: ...t any four to six character PIN code assigned to the target Bluetooth device using the setting procedures below STATE CODE Cradle Dongle connection auto detection Program Begin PIN setting PIN no Set 4 6 character End PIN setting 1AB01 PRO 0 1 2 3 4 5 6 7 8 9 PIN ...

Page 30: ...is beep can be disabled or reconfigured to sound for different durations by using the following programming barcodes Disable inquiry beep Inquiry beep continuously Default Inquiry beep every 10 seconds Inquiry beep every 20 seconds Inquiry beep every 30 seconds Inquiry beep every 40 seconds 5AJ00 5AJ08 5AJ01 5AJ02 5AJ03 5AJ04 ...

Page 31: ...31 Inquiry beep every 50 seconds Inquiry beep every 60 seconds Inquiry beep every 70 seconds 5AJ05 5AJ06 5AJ07 ...

Page 32: ...32 Cradle Beep Loudness Control The beep loudness of cradle can be defined with the following levels Cradle beep off Level 1 Level 2 Level 3 Default Level 4 Level 5 5AK00 5AK01 5AK02 5AK03 5AK04 5AK05 ...

Page 33: ...33 Level 6 Level 7 5AK06 5AK07 ...

Page 34: ...ce cradle to reset the configuration This feature will also force imager to reset the configuration to factory default Note To meet the regulation of air transportation the wireless imager should disconnect with the cradle during shipment All SC5 USB W wireless imagers are suggested to scan the following command before packaging into boxes and ship to customers Force imager to disconnect and sleep...

Page 35: ...AN 13 V V V F EAN 8 V V V FF Code 39 V Interleaved 2 of 5 V i Industrial 2 of 5 i Matrix 2 of 5 B Codabar Code 128 V V Code 93 V two digits Code 11 V One digit O MSI Plessey V UK Plessey V Telepen S Standard 2 of 5 V V i China Post t Italian Pharmacode p Code 16K PDF417 V EAN UCC Composite RC Databar RSS 14 R4 Databar RSS Limited RL Databar RSS Expanded RX Micro PDF U ...

Page 36: ...5mil 5mm 50mm for 4mil Scan Speed 300 scans sec Resolution 0 1mm 4mil Code39 PCS 90 Print Contrast 30 or more Scanning Angle Front 60 Rear 60 Yaw 70 Decode Capability Auto discriminates all standard barcodes and some 2D symbologies including PDF 417 and RSS code Other symbologies can be ordered optionally Beeper Operation 7 tones or no beep Indicator on imager Green Red led Mechanical Length 187 m...

Page 37: ...d wedge USB Electrical Input Voltage Cradle 5 VDC 10 VDC Power Operating Cradle 500 mW Power Standby Cradle 350 mW Current Operating Cradle 100 mA Current Standby Cradle 70 mA Charge Current Cradle 600mA Input Voltage Imager 3 4V 4 2V Power Operating Imager 925 mW Power Standby Imager 59 mW Current Operating Imager 250 mA Current Standby Imager 16 mA Depth handle 33 mm ...

Page 38: ...m upgrade Enabled by built in flash memory Programmable characteristics Code type selection check digit selection Decoding option Decoding option Transmitted character delay Header selection trailer selection message suffix good read beep tone and volume scanner trigger selection Keyboard emulation type intermessage delay keyboard type and keyboard language Serial interface type ACK NAK Xon Xoff R...

Page 39: ...Link established Blink once A special beep Hardware fail Flash Program download Flash Program checksum fail Flash Data transmitting ON High freq Beep for 300msec Data trans Fail ON for 300msec Error beep Data trans OK ON for 200msec Good beep Low battery 3 2V Trigger is pressed Flash ...

Page 40: ...ecting Blink Link established ON Hardware fail Flash Data receiving from the scanner ON for 0 5sec Barcode data proof or transmitted Good beep Data send to the host Fail Error beep Program download Flash Program checksum Fail Flash Battery LED Idle Charging Blink Battery full ON Battery charger Fail Blink ...

Page 41: ...Scan the Program barcode on the parameter setting part 2 Enter the option mode by scanning the Option Bar Code also on the Parameter setting part 3 To the right of the option barcode the necessary alphanumeric inputs are listed Scan these alphanumeric entries from the back fold out page To confirm above steps you must scan the Finish barcode on the back fold out page 4 Once you have finished progr...

Page 42: ...n Alphanumeric Entry Interface selection Keyboard Wedge RS 232 Wand emulation USB Keyboard RS 232 Auto detection Reserved 00 01 02 03 04 05 Program Exit Program Barcode Option Barcode Exit Barcode Back Fold Out Finish barcode ...

Page 43: ...ry interface default for other type interface By plugging different cables setting right interface then the cradle will be changed to another interface However you must make sure which cable you need Keyboard RS232 UBS Auto detection By setting this function it will automatically select the Keyboard wedge or RS 232 or UBS interface for user Option Bar Code Option Alphanumeric Entry Interface selec...

Page 44: ... simple process without any changes of software or hardware Keyboard Type Select keyboard type connector of your host computer Cradle must be selected to the appropriate host interface cable converter Option Bar Code Option Alphanumeric Entry Keyboard type IBM AT PS 2 Reserved Reserved Reserved Reserved Reserved Reserved 00 01 02 03 04 05 06 Program ...

Page 45: ... been lost you may need to set 05 or 06 to match your host keyboard speed Function Key Set Enable imager can output code as pressing function key in your application program while the barcode datas contain ASCII value between 0116 to 1F16 Refer to ASCII table Numeric Key The Keypad has to be selected if your application program is only keypad numeric code acceptable So cradle will output code as p...

Page 46: ...Spanish Swedish Switzerland UK Latin American Japanese 00 01 02 03 04 05 06 07 08 09 10 11 12 Keyboard speed 0 8 0 high clock rate 8 low clock rate 00 08 03 Function key Disable Enable 00 01 Alpha Numeric key Alphabetic key Numeric keypad Num lock state only Alt Keypad 00 01 02 ...

Page 47: ...ates keyboard timing and pass keyboard present status to the PC during power on Inter character delay This delay is inserted after each data characters transmitted If the transmission speed is too high the system may not be able to receive all characters Adjust it and try out suited delay to make system work properly Block transmission delay It is a delay timer between barcode data output The feat...

Page 48: ...Bar Code Option Alphanumeric Entry Caps lock Caps lock ON Caps lock OFF 00 01 Power on simulation Disable Enable 00 01 Inter character delay 00 99 msec 00 99 02 Block transmission delay 00 99 10 msec 00 99 10 Program ...

Page 49: ... the imager will issue a 5 warning beeps Xon Xoff When the host computer is unable to accept data it sends a Xoff code to inform the cradle to suspend data transmission and Xon to continue ACK NAK When the ACK NAK protocol is used the cradle waits for an ACK acknowledge or not acknowledge from the host computer after data transmission and will resend in response to a NAK Inter character delay It i...

Page 50: ...lphanumeric Entry Flow control None RTS CTS Xon Xoff ACK NAK RTS CTS bracket mode 00 01 02 03 04 Inter character delay 00 99 msec 00 99 00 Block transmission delay 00 99 10 msec 00 99 00 Response delay 00 99 100 msec 00 99 20 Program ...

Page 51: ...tion Alphanumeric Entry Baud rate 300 BPS 600 BPS 1200 BPS 2400 BPS 4800 BPS 9600 BPS 19200 BPS 38400 BPS 00 01 02 03 04 05 06 07 Parity None Odd Even 00 01 02 Data bit 8 bits 7 bits 00 01 Stop bit One bit Two bits 00 01 Program ...

Page 52: ...52 ...

Page 53: ...Pin Assignments 10 pin AS Series 10 pin RJ 45 Connector Pin RS 232 Keyboard 1 I F I F 2 NA NC 3 TXD NC 4 NC CLK PC 5 GND DATA PC 6 CTS DATA KB 7 RXD NC 8 RTS CLK KB 9 GND GND 10 NC GND 1 2 4 3 5 6 7 8 9 10 ...

Page 54: ...P Female 1 DATA PC DATA KB 2 NC NC 3 GND GND 4 VCC 5V NA 5 CLK PC CLK KB 6 NC NC RS 232 DB 9F Connector To Host Side Pin Definition 1 NC 2 TXD 3 RXD 4 NC 5 GND 6 NC 7 CTS 8 RTS 9 NC 4 2 3 1 8 6 9 7 5 4 3 1 2 5 3 4 5 6 2 1 Mini DIN 6P Male Connector 6 Mini DIN 6P Female Connector ...

Page 55: ... Continue Imager always keeps reading and it does not matter when trigger button is pressed or duration is elapsed Test only For test of scan performance only It is improper to be utilized to check the accuracy of transmitted data Double read timeout The imager will require a several times successful decoding to confirm the data when enabled The more confirming times required the more inhibitive m...

Page 56: ...ead off Momentary Alternate Timeout off Continue Test only 00 01 02 03 04 05 Stand by duration 01 99 second 00 99 06 Double read timeout 01 99 10 msec 01 99 50 Double confirm 00 09 00 no double confirm 00 09 00 Supplement Check Counter 00 64 verifications 00 64 30 Program ...

Page 57: ...fixed length barcode decoded The values of setting have no effect on certain symbologies with fixed length You can specify the settings for individual barcode by the min max code length setting of each barcode Notes 1 Please set the min max length if you have special demand for individual barcode 2 Include the Check sum digits if you want to set Global min max code length Inverted image scan Set E...

Page 58: ...58 Exit Option Bar Code Option Alphanumeric Entry Global min code length 00 99 00 99 04 Global max code length 00 99 00 99 99 Inverted image scan Disable Enable 00 01 Program ...

Page 59: ...mager will light up to indicate a good barcode reading Beeper indication After each successful reading the imager will beep buzzer to indicate a good barcode reading and its Beep loudness Beep tone freq and Beep tone duration are adjustable Beep loudness Beep tone freq Beep tone duration You can adjust Beep Loudness Beep tone and Beep duration for a good reading upon favorite usage Exit ...

Page 60: ...ric Entry Power on alert Disable Enable 00 01 LED indication Disable Enable 00 01 Beeper indication Disable Enable 00 01 Beep loudness 00 07 00 off 00 07 07 Beep tone freq 00 99 100Hz 00 99 26 Beep tone duration 00 99 10 msec 00 99 08 Program ...

Page 61: ... instead of reading anything when the truncate value is more than the barcode data digits or the value of Truncate Leading is overlapped with that of the Ending The maximum value of truncate digits is 15 Code ID setting Code ID setting is a character used to represent the symbol upon a succeeding reading A Code ID setting is prefixed to the data begin or end transmitted if the feature is selected ...

Page 62: ...Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Check sum transmission Disable Enable 00 01 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH A Program ...

Page 63: ...cting the group number Example Group 2 set 02 or 20 Group 1 and 4 set 14 or 41 Notes 1 Group number set to 0 means that no group insertion required 2 Details about the Insert Group settings please refer to page 123rd 126th and page 132nd ASCII code table Supplement digits The Supplement digits barcode is the supplemental 2 or 5 characters for WPC code Format Leading Zero Data Digits 11 Digits Chec...

Page 64: ... Insert group number selection 00 44 00 44 00 Supplement digits None 2 digits 5 digits 2 5 digits UCC EAN 128 2 UCC EAN 128 5 UCC EAN 128 All 00 01 02 03 04 05 06 07 Truncation Expansion None Truncate leading zero Expand to EAN13 00 01 02 The Program ...

Page 65: ...Enable checks sum will be transmitted Truncate leading ending Refer to Truncate leading ending of UPCA Code ID setting Refer to Code ID setting of UPCA Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Check sum transmission Disable Enable 00 01 Truncate leading 0 15 00 15 00 Program ...

Page 66: ...66 Exit Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH E ...

Page 67: ...plement Digits 2 or 5 or UCC EAN 128 Expansion The expansion function is used only for UPCE and EAN 8 code reading It extends to 13 digits with 0 digits when the feature is enabled Example Barcode 0123654 Output 0012360000057 UPCE 1 Enable imager to read UPCE with leading digit 1 Option Bar Code Option Alphanumeri c Entry Insert group number selection 00 44 00 44 00 Program ...

Page 68: ...s 5 digits 2 5 digits UCC EAN 128 2 UCC EAN 128 5 UCC EAN 128 All 00 01 02 03 04 05 06 07 Truncation Expansion None Truncate leading zero Expand to EAN13 Expand to UPCA 00 01 02 03 Expansion Disable Enable 00 01 UPCE 1 Disable Enable 00 01 ...

Page 69: ...s sum will be transmitted Truncate leading ending Refer to Truncate leading ending of UPCA Truncate leading zero Refer to Truncation Expansion of UPCA The Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Check sum transmission Disable Enable 00 01 Truncate leading 0 15 00 15 00 Program ...

Page 70: ...70 Exit Truncate ending 0 15 00 15 00 ...

Page 71: ...The ISBN International Standard Book Number and ISSN International Standard Serial Number are two kinds of barcode for book and magazines The ISBN is 10 digits with leading 978 and the ISSN is 8 digits with leading 977 of the EAN 13 symbology Example Barcode 9789572222720 Output 9572222724 Example Barcode 9771019248004 Output 10192484 Option Bar Code Option Alphanumeric Entry Code ID setting 00 ff...

Page 72: ...it Supplement digits None 2 digits 5 digits 2 5 digits UCC EAN 128 2 UCC EAN 128 5 UCC EAN 128 All 00 01 02 03 04 05 06 07 ISBN ISSN conversion Disable Enable 00 01 ISBN ID setting 00 ffH ASCII code 00 ffH I ...

Page 73: ...ng ending Refer to Truncate leading ending of UPCA Code ID setting Refer to Code ID setting of UPCA Insertion group number selection Refer to page 57th Insertion group number selection of UPCA Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Check sum transmission Disable Enable 00 01 Truncate leading 0 15 00 15 00 Program ...

Page 74: ...74 Exit Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH 00 ffH FF Insert group number selection 00 44 00 44 00 ...

Page 75: ...nsion Refer to Truncate Leading zero of UPCE Expansion Refer to Expansion of UPCE Option Bar Code Option Alphanumeric Entry Supplement digits None 2 digits 5 digits 2 5 digits UCC EAN 128 2 UCC EAN 128 5 UCC EAN 128 All 00 01 02 03 04 05 06 07 Truncation Expansion None Truncate leading zero Expand to EAN13 00 01 02 Program ...

Page 76: ...76 Exit Expansion Disable Enable 00 01 ...

Page 77: ... Max Code Length is in effect The length is defined as to the actual barcode data length to be sent Label with length exceeds these limits will be rejected Make sure that the Minimum length setting is no greater than the Maximum length setting or otherwise all the labels of the symbology will not be readable In particular you can see the same value for both Minimum and Maximum reading length to fo...

Page 78: ...n Disable Enable 00 01 Check sum transmission Disable Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH ...

Page 79: ...t transmit the embedded appending code space for Code 39 If Enable and other symbols were read again with the appended code then codes will be transmitted without Code ID Preamble and Prefix When a symbol was decoded without the appended code the data will be transmitted without Code ID and Prefix but the Postamble Suffix codes are appended This function is used when the first number of code 39 is...

Page 80: ...80 Exit Format Standard Full ASCII 00 01 Append Disable Enable 00 01 Start end transmission Disable Enable 00 01 ...

Page 81: ...ble checksum will be transmitted Max Min code length Refer to Max Min code length of Code 39 Truncate leading ending Refer to Truncate leading ending of UPCA Code ID setting Refer to Code ID setting of UPCA Insertion group number selection Refer to page 57th Insertion group number selection of UPCA Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Check sum verification Disable E...

Page 82: ...Disable Enable 00 01 Max code leading 00 64 00 64 00 Min code leading 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH i Insert group number selection 00 44 00 44 00 ...

Page 83: ...ate leading ending Refer to Truncate leading ending of UPCA Code Id setting Refer to Code ID setting of UPCA Insertion group number selection Refer to page 57th Insertion group number selection of UPCA Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Program ...

Page 84: ...84 Exit Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH i Insert group number selection 00 44 00 44 00 ...

Page 85: ...le checksum will be transmitted Max Min code length Refer to Max Min code length of Code 39 Truncate leading ending Refer to Truncate leading ending of UPCA Code ID setting Refer to Code ID setting of UPCA Insertion group number selection Refer to page 57th Insertion group number selection of UPCA Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Checksum Verification Disable Ena...

Page 86: ...Disable Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH B Insert group number selection 00 44 00 44 00 ...

Page 87: ... checksum will be transmitted Max Min code length Refer to Max Min code length of Code 39 Truncate leading ending Refer to Truncate leading ending of UPCA Code Id setting Refer to Code ID setting of UPCA Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Checksum Verification Disable Enable 00 01 Start Data Digits Variable Checksum Optional End Program ...

Page 88: ...t Checksum Transmission Disable Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH ...

Page 89: ...ur pairs of Start End pattern you may select one pair to match your application Start End Transmission Refer to Start End Transmission of Code 39 Option Bar Code Option Alphanumeric Entry Insert group selection 00 44 00 44 00 Start End type ABCD ABCD abcd abcd ABCD TN E Abcd tn e 00 01 02 03 Start End transmission Disable Enable 00 01 Program ...

Page 90: ...The checksum is made as the sum module 103 of all data digits Checksum Transmission By setting Enable checksum will be transmitted Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Checksum Verification Disable Enable 00 01 Checksum Transmission Disable Enable 00 01 Program ...

Page 91: ... The first FNC1 will be translated to C1 and next to be a field separator code as GS 1D16 C1 Data GS Data Checksum Append FNC4 control When Append function is enabled it won t show the data immediately if imager read the barcode includes FNC2 code It will show all data until it read the barcode which doesn t have FNC2 code When FNC4 is enabled the imager will send the data with FNC4 code If the FN...

Page 92: ... Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH Insert group number selection 00 44 00 44 00 Format Standard UCC EAN 128 00 01 Append FNC4 control Disable Enable Enable Enable Disable Ignore Enable Ignore 00 01 02 03 ...

Page 93: ...is feature is only used for UCC EAN 128 format This Field separator code means you can reassign second or after a FNC1 for your usage The default of ASCII code is GS 1D16 UCC EAN 128 ID setting Refer to Code ID setting of UPCA Option Bar Code Option Alphanumeric Entry ISBT enable Disable Enable normal 00 01 Field separator code 00 ffH ASCII code 00 ffH 1DH UCC EAN 128 ID setting 00 ffH ASCII code ...

Page 94: ...ksum is made as the sum module 47 of the numerical values of all data digits Checksum Transmission By setting Enable checksum will be transmitted Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Checksum Verification Disable Enable two digits 00 01 Checksum Transmission Disable Enable 00 01 Program ...

Page 95: ...ing of UPCA Code Id setting Refer to Code ID setting of UPCA Insertion group number selection Refer to page 57th Insertion group number selection of UPCA Option Bar Code Option Alphanumeric Entry Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Program ...

Page 96: ...96 Exit Code ID setting 00 ffH ASCII code 00 ffH Insert group number selection 00 44 00 44 00 ...

Page 97: ...ed upon your selected checksum verification method Max Min code length Refer to Max Min code length of Code 39 Truncate leading ending Refer to Truncate leading ending of UPCA Code ID setting Refer to Code ID setting of UPCA Insertion group number selection Refer to page 57th Insertion group number selection of UPCA Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Checksum Verif...

Page 98: ...Disable Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH O Insert group number selection 00 44 00 44 00 ...

Page 99: ...um Transmission By setting Enable checksum1 and checksum2 will be transmitted upon your selected checksum verification method Max Min code length Refer to Max Min code length of Code 39 Truncate leading ending Refer to Truncate leading ending of UPCA Code ID setting Refer to Code ID setting of UPCA Insertion group number selection Refer to page 57th Insertion group number selection of UPCA Option ...

Page 100: ...n Disable Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH Insert group number selection 00 44 00 44 00 ...

Page 101: ...m Transmission By setting Enable checksum will be transmitted Max Min code length Refer to Max Min code length of Code 39 Truncate leading ending Refer to Truncate leading ending of UPCA Code ID setting Refer to Code ID setting of UPCA Insertion group number selection Refer to page 57th Insertion group number selection of UPCA Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Che...

Page 102: ...n Disable Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH Insert group number selection 00 44 00 44 00 ...

Page 103: ...ax Min code length Refer to Max Min code length of Code 39 Truncate leading ending Refer to Truncate leading ending of UPCA Code ID setting Refer to Code ID setting of UPCA Insertion group number selection Refer to page 57th Insertion group number selection of UPCA Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Checksum Verification Disable Enable 00 01 Checksum Transmission D...

Page 104: ... 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH S Insert group number selection 00 44 00 44 00 Format Numeric only Full ASCII only 00 01 ...

Page 105: ...ble checksum will be transmitted Max Min code length Refer to Max Min code length of Code 39 Truncate leading ending Refer to Truncate leading ending of UPCA Code ID setting Refer to Code ID setting of UPCA Insertion group number selection Refer to page 57th Insertion group number selection of UPCA Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Check sum verification Disable E...

Page 106: ... Disable Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH i Insert group number selection 00 44 00 44 00 ...

Page 107: ... leading ending Refer to Truncate leading ending of UPCA Code Id setting Refer to Code ID setting of UPCA Insertion group number selection Refer to page 57th Insertion group number selection of UPCA Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Max code length 00 64 00 64 11 Min code length 00 64 00 64 11 Program ...

Page 108: ...108 Exit Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH t Insert group number selection 00 44 01 44 00 ...

Page 109: ...ding Refer to Truncate leading ending of UPCA Code Id setting Refer to Code ID setting of UPCA Insertion group number selection Refer to page 57th Insertion group number selection of UPCA Leading A If this function is enabled each prefix of data shall be A Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Max code length 00 64 00 64 12 Program ...

Page 110: ...Min code length 00 64 00 64 09 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 01 ffH p Insert group number selection 00 44 00 44 00 Leading A Disable Enable 00 01 ...

Page 111: ...r to Code ID setting of UPCA Insertion group number selection Refer to page 57th Insertion group number selection of UPCA Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH Program ...

Page 112: ...112 Exit Insert group number selection 00 44 00 ffH 00 44 00 ...

Page 113: ...417 Truncate leading ending Refer to Truncate leading ending of UPCA Code ID setting Refer to Code ID setting of UPCA Insertion group number selection Refer to page 57th Insertion group number selection of UPCA ...

Page 114: ...meric Entry Read Disable Enable 00 01 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH P Insert group number selection 00 44 00 44 00 Escape sequence transmit Disable Enable 00 01 Program ...

Page 115: ... barcode that is printed to the right of the UPC EAN in UCC EAN 128 symbology Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH RC Insert group number selection 00 44 00 44 00 Program ...

Page 116: ...116 Exit UCC EAN128 emulation Disable Enable 00 01 ...

Page 117: ...r to Code ID setting of UPCA Insertion group number selection Refer to page 57th Insertion group number selection of UPCA UCC EAN 128 emulation Refer to Transmission Code ID transmission must be set as AIM ID enable Then C1 will be identified as prefix of barcode data transmission Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Program ...

Page 118: ...118 Exit Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH R4 Insert group number selection 00 44 00 44 00 UCC EAN128 emulation Disable Enable 00 01 ...

Page 119: ... Code ID setting Refer to Code ID setting of UPCA Insertion group number selection Refer to page 57th Insertion group number selection of UPCA UCC EAN 128 emulation Refer to UCC EAN 128 emulation of RSS 14 Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Program ...

Page 120: ...120 Exit Code ID setting 00 ffH ASCII code 00 ffH RL Insert group number selection 00 44 00 44 00 UCC EAN128 emulation Disable Enable 00 01 ...

Page 121: ... ending of UPCA Code ID setting Refer to Code ID setting of UPCA Insertion group number selection Refer to page 57th Insertion group number selection of UPCA UCC EAN 128 emulation Refer to UCC EAN 128 emulation of RSS 14 Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Truncate leading 0 15 00 15 00 Program ...

Page 122: ...122 Exit Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH RX Insert group number selection 00 44 00 44 00 UCC EAN128 emulation Disable Enable 00 01 ...

Page 123: ...r to Code ID setting of UPCA Insertion group number selection Refer to page 57th Insertion group number selection of UPCA Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH U Program ...

Page 124: ...124 Exit Insert group number selection 00 44 00 44 00 Escape sequence transmit None GLI protocol ECI protocol 00 01 02 ...

Page 125: ...defined as prefix or suffix characters will be transmitted immediately with the scanned data for all symbologies Up to 22 ASCII characters can be defined as Prefix or Suffix Format of barcode data transmission Prefix Name Preamble ID Code Length Barcode Data ID Postamble Suffix Insert groups ...

Page 126: ...126 Exit Option Bar Code Option Alphanumeric Entry Prefix characters setting None 1 22 characters 00 00 ffH ASCII code Suffix characters setting None 1 22 characters 0D 00 ffH ASCII code Program ...

Page 127: ... be appended before the data transmitted Postamble transmission By setting Enable Postamble will be appended after the data is transmitted Example Add a prefix suffix or preamble postamble for all symbologies In this example you are sending a symbol as a prefix for all symbologies Steps 1 Scan Programming and Prefix characters setting barcode 2 Use the ASCII code table to find the value of 24 3 Sc...

Page 128: ... Entry Preamble characters setting 1 22 characters PREAMBLE 00 ffH ASCII code Preamble transmission Disable Enable 00 01 Postamble characters setting 1 22 characters POSTAMBLE 00 ffH ASCII code Postamble transmission Disable Enable 00 01 Program ...

Page 129: ...nsertion will be positioned at the ending of data Notice Default value 00 indicates the group to be positioned at the leading of data 64 represents for positioning the group at the ending of data Insert data group setting procedure i Define the characters of groups for insertion ii Setup the inserting position of each group in scanned data iii Select one or two groups to insert into specific bar c...

Page 130: ... refer to the specific barcode that you want to use 2 Insert data group 1 4 position The imager offers 4 positions to insert among the symbol The position default value is 00 to indicate no character insertion Beside make sure insertion positions are not greater than the symbols otherwise the insertion data is not effective ...

Page 131: ...1 00 ffH ASCII code Insert G2 characters setting 1 22 characters GROUP2 00 ffH ASCII code Insert G3 characters setting 1 22 characters GROUP3 00 ffH ASCII code Insert G4 characters setting 1 22 characters GROUP4 00 ffH ASCII code Insert data group 1 position 00 64 00 no insertion 00 64 00 Program ...

Page 132: ...132 Exit Insert data group 2 position 00 64 00 no insertion 00 64 00 Insert data group 3 position 00 64 00 no insertion 00 64 00 Insert data group 4 position 00 64 00 no insertion 00 64 00 ...

Page 133: ...l length of the barcode is the number of barcode data except Truncate Leading Ending Digits And the length is a number with two digits Code name transmission This function is to show unknown barcode symbologies that include all readable symbologies of the imager When Enable is selected Code Name will be transmitted before code data you will know what kind of barcode symbology is Case conversion Se...

Page 134: ...ter code data 00 01 Code ID transmission Disable Proprietary ID AIM ID 00 01 02 Code length transmission Disable Enable 00 01 Code name transmission Disable Enable 00 01 Case conversion For barcode data only Disable Upper case Lower case 00 01 02 ...

Page 135: ...135 Test Chart Test Chart Test Chart Test Chart Bar code samples marked with symbol are enabled initially CODABAR PARA CODE 11 PARA CODE 128 PARA CODE 39 PARA CODE 93 PARA EAN 13 PARA ...

Page 136: ...136 PDF 417 STANDRAD 25 PARA CODE 16K EAN 8 PARA INDUSTRIAL 25 PARA UPCE PARA 87549 87549 87549 87549 ...

Page 137: ...137 INTERLEAVED 25 PARA MATRIX 25 PARA MSI PLESSEY PARA UPCA PARA UK PLESSEY PARA RSS Micro PDF ...

Page 138: ...F5 ENQ NAK 6 PgDn F6 ACK SYN 7 F7 BEL ETB 8 Bs F8 BS CAN 9 Tab F9 HT EM A F10 LF SUB B Home Esc VT ESC C End F11 FF FS D Enter F12 CR GS E Insert Ctrl SO RS F Delete Alt SI US L H 2 3 4 5 6 7 0 SP 0 P p 1 1 A Q a q 2 2 B R b r 3 3 C S c s 4 4 D T d t 5 5 E U e u 6 6 F V f v 7 7 G W g w 8 8 H X h x 9 9 I Y i y A J Z j z B K k C L l D M m E N n F O _ o DEL ...

Page 139: ... terminal computer scan the Barcode standard parameter setting list bar code System parameter setting list If you wish to display the current system configuration of your SC5 USB W imager over the host terminal computer scan the System parameter setting list bar code String setting list If you wish to display the string format list scan the String setting list bar code B C Exit ...

Page 140: ...st barcode Reset cradle to factory default settings WARNING Default value initialization If you wish to return the SC5 USB W imager to all the factory default settings scan the above barcode will perform the feature However the cradle will be set to factory default settings at the same time IC Note This feature is only available when Auto Update is enabled see page 12 ...

Page 141: ...141 0 1 2 3 4 5 6 7 8 9 A B C Finish F E D ...

Reviews: