MATRIX 300™ REFERENCE MANUAL
82
6
6.1.2 Matrix 300 4x2 9 mm Liquid Lens Global FOV Diagrams
The following diagrams show the
maximum obtainable
Field of View for 1D and 2D codes
using Processing Mode = Advanced Code Setting.
Depending on the code resolution,
symbology, and number of characters in the code, the Reading Area can be different
from the FOV
. See the reference Reading Diagrams in par. 6.4 for reading area examples.
Horizo
ntal
FOV
in
0
1
2
3
4
5
6
7
8
9
10
11
12
13
0
1
2
5
-1
-2
-5
3
4
-3
-4
mm
5 mils
7.5 mils
15 mils
10 mils
2D Code FOV
Distance
Horizo
ntal
FOV
in
0
2
4
6
8
10
12
14
16
18
20
22
0
2
4
10
-2
-4
-10
6
8
-6
-8
mm
10 mils
12 mils
13 mils
15 mils
1D Code FOV
Distance