7.5 CONFIGURATION
Once connected to Matrix 300™ as described in par. 7.3 or 7.4, you can modify the
configuration parameters as follows:
1.
Press the Calibration Tool button from the Main Menu. Matrix 300™ will download its
permanent memory configuration parameters with the default values (if it is the first time)
to VisiSet™. The Calibration Tool window will be displayed together with the Parameter
Setup window working in Interactive Mode (see par. 7.5.1 and par. 7.5.3).
2.
Edit the Matrix 300™ configuration parameters according to your application
requirements.
3.
Use the
Calibration Tool
to fine tune the reading performance. See par. 7.5.3.
4.
Close the Calibration Tool window and disable the Interactive Mode by pressing the
interactive button.
5.
Save the new configuration to the reader permanent memory by pressing the Send
button.
NOTE:
Especially for lengthy configurations in Interactive Mode, it is always
good practice to periodically send the configuration to
Permanent Memory
to
avoid losing the configuration in Temporary Memory.
6.
Close the Parameter Setup window and press
Disconnect
on the VisiSet™ menu bar
(see Figure 75) or launch
Run
Mode from the VisiSet™ Main menu.
Disconnect
exits
closing communication between Matrix 300™ and VisiSet™, and
causes Matrix 300™ to enter Run Mode. The disconnected reader serial port is now
available.
Run
command
does not close communication between Matrix 300™ and VisiSet™,
and causes
Matrix 300™ to enter Run Mode. In this case the reader output messages
are displayed on the VisiSet™ terminal and the statistics are displayed in the
Statistics window (Statistics enabled).
Содержание Matrix 300
Страница 1: ...REFERENCE MANUAL Matrix 300...
Страница 68: ...MATRIX 300 REFERENCE MANUAL 56 4 Figure 41 ID NET Network Connections with isolated power blocks...
Страница 69: ...CBX ELECTRICAL CONNECTIONS 57 4 Figure 42 ID NET Network Connections with Common Power Branch Network...
Страница 70: ...MATRIX 300 REFERENCE MANUAL 58 4 Figure 43 ID NET Network Connections with Common Power Star Network...
Страница 118: ...MATRIX 300 REFERENCE MANUAL 106 7 Figure 78 Options Communication Serial Port Figure 79 Options Communication Ethernet...
Страница 160: ......