background image

6

Magellan

TM

 8300/8400

Scale Zero Push Button

The Scale Zero Push Button is used for two functions as described in 

Table 3

. This button has no function on “scanner-only” models.

Table 3. Scale Zero Push Button Functions

EAS-Enabled Systems

Once the system is activated, EAS security tags are automatically deactivated by 
passing items over the EAS antenna located beneath the scanner’s platter.

PRESS

DURATION

FUNCTION

COMMENT

Momentary

Zero Scale

When programmed to do so, the yellow Scale LED should be lit when no 
weight is on the scale, indicating scale at zero. If it is not, press the 
switch to zero the scale. The unit will sound a “click” upon pressing the 
button.

Momentary 
(when the 
scale’s primary 
indication shows 
an under zero 
condition)

Scale power 
cycle

When programmed to do so, and when certain conditions are met, 
pressing this button will initiate a scale power cycle. When the scale zero 
button is pushed and the weight on the scale is close to zero, the scale 
will zero normally like the zero scale function above. Otherwise, the 
scale will go through a power cycle. If the scale is able to find zero after 
the power cycle, the scale will perform normally. Otherwise, the scale’s 
primary indication will display a non-weight indication.

4 Seconds

Scale Diag-

nostics Mode

a

This mode allows system support personnel to troubleshoot problems 
with the scale. Cycle power to exit Scale Diagnostics Mode.

a. Diagnostics Mode is meant for use by trained systems support personnel. Users should not need to ini-

tiate this function under normal circumstances.

NOTE

Electronic Article Surveillance (EAS) systems are aftermarket options, and 
are installed by either Sensormatic

®

 or Checkpoint

®

 technicians at your site 

depending upon which EAS product package is purchased to use with your 
scanner.

Содержание MAGELLAN 8300

Страница 1: ...om Monday Friday 6 AM to 5 PM Pacific Time Bulk Discounts FREE SHIPPING SE Habla Espa ol Free ground shipping to the continental USA on orders over 100 For Help Call 1 800 241 6264 Datalogic Magellan...

Страница 2: ...MagellanTM 8300 8400 Quick Reference Guide...

Страница 3: ...6 4879456 4939355 4939356 4943127 4963719 4971176 4971177 4991692 5001406 5015831 5019697 5019698 5086879 5115120 5144118 5146463 5179270 5198649 5200597 5202784 5208449 5210397 5212371 5212372 521427...

Страница 4: ...any Software 2 2 End User shall not copy modify decompile disassemble reverse engineer or otherwise reproduce or remanufacture the Software whether modified or unmodified nor sell assign sublicense di...

Страница 5: ...TERRUPTION OF BUSINESS OR SERVICE OR FOR ANY OTHER SPECIAL CONSEQUENTIAL CONTINGENT INDIRECT INCIDENTAL PUNITIVE EXEMPLARY OR OTHER SIMILAR DAMAGES EVEN IF DATALOGIC HAS BEEN ADVISED OF THE POSSIBILIT...

Страница 6: ...er of this manual Controls and Indicators The control panel consists of an indicator LED and two push buttons as shown in Figure 1 The bottom most button also serves as an indicator LED for scale func...

Страница 7: ...For best scanning results Move items through the scan zone in their natural orientation It s not necessary to reorient the bar code toward either the horizontal or vertical scan window Sliding or push...

Страница 8: ...tional raised Produce Bar or Produce Rail features conveniently ensure that items do not rest on the counter or other non weighing surfaces With weighed items in place enter PLU Price Look Up data as...

Страница 9: ...i cally switched off and the unit has entered Sleep Mode due to extended inactivity Host Disabled Scanner Green LED 100 mS on 900 mS off Host has disabled scanning Field Replace able Unit FRU Warning...

Страница 10: ...e lowest setting then volume increases on subsequent press es Four vol ume levels are available Hold then release when the beeper sounds Increments tone Press the push button for approximately 2 secon...

Страница 11: ...certain conditions are met pressing this button will initiate a scale power cycle When the scale zero button is pushed and the weight on the scale is close to zero the scale will zero normally like t...

Страница 12: ...Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est confrome la norme NMB 003 du Canada LASER Class CLASS 1 LASER PRODUCTAPPARECCHIO LASER CLASSE 1 LAS...

Страница 13: ...ing to add an adaptive scale to their unit at a later date Until such time as the adaptive scale is installed the four spacers should be left in place to ensure that the Platter rests evenly at its co...

Страница 14: ...presentatives use of product with any other instrument equipment or apparatus modification or alteration of product or units with Warranty Void labels that have been tampered with External cables and...

Страница 15: ...the negligence of Customer its agents or employees In the absence of specific written instructions for the return of product to Customer Datalogic will select the carrier but Data logic shall not ther...

Страница 16: ...one If the seal of the system are missing or broken the instrument does not conform and should be put out of service Equipment Type Barcode Scanning and Weighing Equipment Class Apparatus 830x 840x 83...

Страница 17: ...Datalogic Scanning KK Telephone 81 0 3 3491 6761 japan scanning datalogic com Latin America Datalogic Scanning Inc Telephone 305 742 2206 latinamerica scanning datalogic com Singapore Datalogic Scanni...

Отзывы: