background image

PRODUCT REFERENCE GUIDE   

307

9

0

Содержание Magellan 1500i

Страница 1: ...MAGELLAN 1500i PRODUCT REFERENCE GUIDE Omni Directional Imaging Scanner...

Страница 2: ...documentation Electronic versions of this document may be downloaded from the Datalogic website www datalogic com If you visit our website and would like to make comments or suggestions about this or...

Страница 3: ...Do Not Use Abrasive Cleansers 16 CHAPTER 2 PROGRAMMING 17 About Programming your Scanner 17 Programming with Barcodes 18 Getting Started 19 Programming Mode 19 Programming Session 20 If You Make a Mis...

Страница 4: ...terface Options 89 RS 232 Interface Features 90 RS 232 Baud Rate 90 RS 232 Number of Data Bits 92 RS 232 Number of Stop Bits 92 RS 232 Parity 93 RS 232 Hardware Control 94 RS 232 Intercharacter Delay...

Страница 5: ...d 144 EAN 8 145 EAN 8 Enable 145 EAN 8 Check Character Transmission 146 Expand EAN 8 to EAN 13 147 EAN 8 Minimum Read 148 EAN 8 Guard Insertion 149 EAN 8 Guard Substitution 150 EAN 8 Jan 8 Both Guards...

Страница 6: ...39 Check Character Transmission 199 Code 39 Full ASCII 200 Code 39 Minimum Read 201 Code 39 Length Control 202 Code 39 Length 1 203 Code 39 Length 2 204 Code 39 Stitching 205 Code 39 Require Margins 2...

Страница 7: ...cter Transmission 252 Standard 2 of 5 Minimum Read 253 Standard 2 of 5 Correlation 254 Standard 2 of 5 Length Control 255 Standard 2 of 5 Length 1 256 Standard 2 of 5 Length 2 257 2D Symbologies Posta...

Страница 8: ...l Mail 285 Royal Mail Enable 285 Kix 286 Kix Enable 286 Australia Post 287 Australian Post Enable 287 Japan Post 288 Japan Post Enable 288 IMB 289 IMB Enable 289 Sweden Post 290 Sweden Post Enable 290...

Страница 9: ...MAPPINGS 323 USB Function Key Usage Map 323 Scanset 1 Function Key Map 324 Scanset 2 Function Key Map 324 Scanset 3 102 Key Function Key Map 325 Scanset 3 122 Key Function Key Map 326 Japanese DOS Fun...

Страница 10: ...viii MAGELLAN 1500I NOTES...

Страница 11: ...ng connection programming product and cable specifications and other useful references For additional information such as installation maintenance troubleshooting and warranty information see the Quic...

Страница 12: ...other host device Upon completing the connection via the appropriate interface instructions below proceed to the Interface Related Features section of this manual and scan the barcode to select the c...

Страница 13: ...MANUAL CONVENTIONS PRODUCT REFERENCE GUIDE 3 Figure 2 Scanner Features Front View Tilting Stand Good Read Light Pipe Scan Window Beeper Grille Illumination LEDs Scanner Button...

Страница 14: ...CONNECTING THE SCANNER 4 MAGELLAN 1500I Figure 3 Scanner Features Bottom View Power Power interface Cable Latch Release Hole Tilting Stand Interface EAS Cable...

Страница 15: ...ertical surface For more information go to Installing the Tilting Stand Riser starting on page 6 or Dimen sions on page 12 Figure 4 Tilting Stand Riser and Wall Mounts Tilting Stand Riser Wall Mounts...

Страница 16: ...tch in the enclosure as shown below After the stand is installed the wire can be pulled to extend the wire for accessibility if needed If the EAS cable is not needed the EAS cable can be tucked inside...

Страница 17: ...sible Notch EAS Cable 4 After the Stand or Riser is firmly attached plug the Interface cable into the bottom of the scanner If installing the Tilting Stand you can plug the cable in directly and insta...

Страница 18: ...first open the Riser door to facilitate plugging in the cable Pull the riser door straight out then push down to swing open 6 Plug the interface cable straight in and ensure it clicks securely into pl...

Страница 19: ...ve the stand Failure to do so may result in damage to the scanner or stand 1 Unplug the Power Interface Cable by inserting a paper clip or similar object into the latch release hole 2 If the EAS cable...

Страница 20: ...y Front Window Stand L Bracket Wall Mount Installation 1 Install the bottom cover on the unit by inserting tabs into the bottom of the scanner at the front edge and snapping in place at the back Ensur...

Страница 21: ...WALL MOUNT INSTALLATION PRODUCT REFERENCE GUIDE 11 3 Insert the cable in the scanner ensuring it clicks securely into place 4 The Scanner can now be placed in the L bracket facing the front or on eit...

Страница 22: ...TIONAL STAND RISER MOUNT 12 MAGELLAN 1500I Dimensions Figure 5 Tilting Stand Dimensions 138 61 75 Top View Front View Side View Figure 6 Riser Stand Dimensions 106 75 59 Side View Front View Bottom Vi...

Страница 23: ...GUIDE 13 Figure 7 Dimensions for Scanner with L Bracket Wall Mount 75 75 60 84 Rear Mount Side View Rear Mount Front View Bottom View Side Mount Front View Figure 8 Dimensions for Mounting with Screws...

Страница 24: ...the aimer over the barcode to be read press and release the button Upon a successful read the button will blink bright green and the GreenSpot will illumi nate indicating the barcode has been read See...

Страница 25: ...anufacturer Approved Cleaning Materials Datalogic recommends the use of the following cleaners on its products APPROVED CLEANERS Hydrogen Peroxide not to exceed a 3 solution Chlorine bleach not to exc...

Страница 26: ...ny part of the scanner as they can cause damage which will adversely affect scanning performance Use of such materials either alone or in combination with other cleaning agents will void the manufactu...

Страница 27: ...scanner s programmable feature settings can be modified to accommodate your system s unique requirements If you need to change these settings custom programming can be accomplished using one of the fo...

Страница 28: ...the host computer along with the barcode data This combination of barcode data and supplementary user defined data is called a message string The features in this chapter can be used to build specific...

Страница 29: ...as been enabled as an option The scanner will exit Programming Mode under any of the following conditions the programming sequence has been completed or the Enter Exit Programming Mode bar code is sca...

Страница 30: ...he currently active interface will be implemented Additionally when programming a feature requiring you to scan single digits to set a multi digit number such as Minimum Label Length do not scan bar c...

Страница 31: ...ming sessions Return to Factory Settings Scan the bar code below to return the scanner to the default settings configured at the fac tory for the currently active interface This bar code is typically...

Страница 32: ...ities Create and print your own programming barcode labels for scanning Create save modify upload and download configuration files Examine scanner configuration and compare to other files or default v...

Страница 33: ...hat can be used to accom plish this Hold the Scan Button 1 Unplug the unit if needed 2 While holding down the Scan Button on the top of the unit plug the scanner in 3 Quickly release the button as soo...

Страница 34: ...age 36 Accelerometer Detect Threshold on page 37 Accelerometer Reject Threshold on page 38 Accelerometer Delay To Stationary on page 39 Accelerometer Inmotion Threshold on page 40 LED AND BEEPER INDIC...

Страница 35: ...age 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you intend to scan 3 Complete...

Страница 36: ...ion from the barcodes below You ll nee 3 d to cover any unused barcodes on this and the facing page to ensure that the scanner reads only the barcode you intend to scan 4 Complete the programming sequ...

Страница 37: ...u ll need to cover any unused barcodes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan 3 Scan the appropriate digits from the Alpha Numeric Keypad in...

Страница 38: ...top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you intend to sca...

Страница 39: ...need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you intend to scan 3 Complete the programming sequence by scanning the Enter Exit Prog...

Страница 40: ...need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you intend to scan 3 Complete the programming sequence by scanning the Enter Exit Progr...

Страница 41: ...is feature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to...

Страница 42: ...eature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensu...

Страница 43: ...ER EXIT PROGRAMMING MODE PRODUCT REFERENCE GUIDE 33 Handheld State When enabled places the scanner in Handheld State of operation 150000 CR Handheld State Disable 150001 CR Handheld State Enable DEFAU...

Страница 44: ...one Label Proofing is enabled 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and...

Страница 45: ...des on this and the facing page to ensure that the scanner reads only the barcode you intend to scan 3 Scan the appropriate digits from the Alpha Numeric Keypad in Appendix C that repre sent the desir...

Страница 46: ...y unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you intend to scan 3 Scan the appropriate digits from the Alpha Numeric Keypad in Appendix C to represe...

Страница 47: ...tting the Reject Threshold page 38 to LOWEST while this feature is set to HIGHEST will result in the scanner rejecting all motion inputs Accelerometer Detect Threshold Lowest Accelerometer Detect Thre...

Страница 48: ...this feature to LOWEST while the Detect Threshold page 37 is set to HIGHEST will result in the scanner rejecting all motion inputs Accelerometer Reject Threshold Lowest Accelerometer Reject Threshold...

Страница 49: ...o Stationary below You ll need to cover any unused barcodes on this and the facing page to ensure that the scanner reads only the barcode you intend to scan 3 Scan the appropriate digits from the Alph...

Страница 50: ...erActiveMode Handheld State for the device to remain in ScannerActiveMode HandheldState Accelerometer Inmotion Threshold Lowest 150901 CR Accelerometer Inmotion Threshold Low 150902 CR Accelerometer I...

Страница 51: ...es or enables the indication that the scanner has finished all its power up tests and is now ready for operation NOTE This feature is configurable so the beep can be replaced with a wav file usually a...

Страница 52: ...OGRAMMING MODE 42 MAGELLAN 1500I External Read Indicator ERI NOTE This feature is available only through use of a special cable ERI Active State Active Low ERI Active State Active High DEFAULT 00F900...

Страница 53: ...illiseconds 10ms or 0 01 seconds To configure this feature 1 Scan the Enter Exit Programming Mode barcode above to place the unit in Pro gramming Mode 2 Scan Set ERI Timeout followed by the two digits...

Страница 54: ...State 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensur...

Страница 55: ...ter Exit Programming Mode barcode at the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner...

Страница 56: ...ng Mode barcode at the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar...

Страница 57: ...Programming Mode barcode at the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads onl...

Страница 58: ...nd to scan 3 Scan the appropriate digits from the Alpha Numeric Keypad in Appendix C that repre sent the desired good read beep length setting The selectable range is 1 255 which is the timeout in 10...

Страница 59: ...ogramming Mode barcode at the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only...

Страница 60: ...re multiple output structures there is a delay after the beep has finished This delay is equal to the Good Read Beep Length on page 48 To set the Good Read When to Indicate feature 1 Scan the Enter Ex...

Страница 61: ...st enable disable commands illumination stays on when disabled Enable Illumination is controlled by host enable disable commands illumination is on when enabled and off when disabled To set this featu...

Страница 62: ...s used but it goes off during sleep mode disable mode To set this feature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan your selection from the barcodes below You ll nee...

Страница 63: ...the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you intend to...

Страница 64: ...s playing To set this feature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan your selection from the barcodes below 3 Complete the programming sequence by scanning the En...

Страница 65: ...Programming Mode barcode at the top of the page 2 Scan your selection from the barcodes below 3 Complete the programming sequence by scanning the Enter Exit Programming Mode barcode 150200 CR Green Sp...

Страница 66: ...re Retrieval Timeout on page 59 Image Capture Delay on page 61 Image Format on page 62 Image Size on page 63 Image Brightness on page 64 Image Contrast on page 66 Image Compression on page 68 Region o...

Страница 67: ...WVGA 752X480 2 SXGA 1280x1027 3 CIF 320x240 B brightness value in ASCII B uses scanner s configuration value CI_IMAGE_BRIGHTNESS else 0 thru 9 specifies brightness C contrast value in ASCII C uses sca...

Страница 68: ...ROGRAMMING MODE 58 MAGELLAN 1500I Image Destination Specifies the destination for pictures images taken with a camera button press 042500 CR Image Destination Disable 042503 r Image Destination Host p...

Страница 69: ...uests via button press NOTE 042300 CR If set to 0 the picture retrieval timeout will not be used and a picture will remain accessible until another is taken or the scanner is reset Picture Retrieval T...

Страница 70: ...Picture Retrieval Timeout continued Picture Retrieval Timeout 6 seconds 042307 CR Picture Retrieval Timeout 7 seconds 042308 CR Picture Retrieval Timeout 8 seconds 042309 CR Picture Retrieval Timeout...

Страница 71: ...es the amount of time after the image capture is initiated by a button press until the picture is taken 042700 CR Image Capture Delay 0 seconds 042701 CR Image Capture Delay 1 second 042702 CR Image C...

Страница 72: ...NG MODE 62 MAGELLAN 1500I Image Format This feature specifies the output format for images taken using the camera function of the scanner Choices are JPG BMP 03E900 CR Image Format JPG 03E901 CR Image...

Страница 73: ...Maximum image height and width Largest image Half VGA Half of the size of a regular VGA image 320 x 240 pixels Smallest image Scaled VGA Video Graphics Array 640 x 480 pixels ROI The size of an ROI i...

Страница 74: ...e selectable range is from 0 to 10 with 10 being the brightest 03EB00 CR Image Brightness 0 03EB01 CR Image Brightness 1 03EB02 CR Image Brightness 2 03EB03 CR Image Brightness 3 03EB04 CR Image Brigh...

Страница 75: ...IMAGING FEATURES ENTER EXIT PROGRAMMING MODE PRODUCT REFERENCE GUIDE 65 Image Brightness continued Image Brightness 8 Image Brightness 9 Image Brightness 10 03EB08 CR 03EB09 CR 03EB0A CR...

Страница 76: ...The selectable range is from 0 to 10 with 0 being the lowest and 10 being the highest contrast 03EC00 CR Image Contrast 0 03EC01 CR Image Contrast 1 03EC02 CR Image Contrast 2 03EC03 CR Image Contrast...

Страница 77: ...IMAGING FEATURES ENTER EXIT PROGRAMMING MODE PRODUCT REFERENCE GUIDE 67 Image Contrast continued Image Contrast 8 Image Contrast 9 Image Contrast 10 03EC08 CR 03EC09 CR 03EC0A CR...

Страница 78: ...ng image compression factor 03ED05 CR Image Compression 5 03ED0A CR Image Compression 10 03ED19 CR Image Compression 25 03ED32 CR Image Compression 50 03ED46 CR Image Compression 70 03ED50 CR Image Co...

Страница 79: ...inate set of 0 639 512 1023 will produce the bottom left section of a full size image NOTE Picture coordinates are NOT defined on a Cartesian coordinate plane Byte 0 1 16 bit hex value xmin Byte 2 3 1...

Страница 80: ...upper left quadrant 04EC028004FF00000200 CR Region of Interest upper right quadrant 04EC00000280020003FF CR Region of Interest lower left quadrant 04EC028004FF020003FF CR Region of Interest lower righ...

Страница 81: ...le Set B always used Byte0 nonzero Byte1 zero Reg values for toggle Set A always used Byte0 nonzero Byte1 nonzero Reg values toggle between Set A and Set B To set this feature 1 Scan the Enter Exit Pr...

Страница 82: ...mode In Timer Expiration mode a single host command enters Cell Phone mode but it is exited at timer expiration The timer is not restarted on a label read In Always On mode the scanner stays on regard...

Страница 83: ...lects a variable setting or percentage of frames dedicated to cell reading NOTE 047100 CR Cell Mode Percent 2 5 Very Low 047101 r Cell Mode Percent 5 Low 047102 r Cell Mode Percent 10 Medium 047103 r...

Страница 84: ...OEM Scanner Device Type on page 88 USB OEM Scanner Device Type on page 88 RS 232 INTERFACE FEATURES starting on page 90 RS 232 Baud Rate on page 90 RS 232 Number of Data Bits on page 92 RS 232 Number...

Страница 85: ...to select the correct interface type since you can cause damage to the scanner and or POS terminal by attempting to change to an incompatible interface ALWAYS make interface selections with the host c...

Страница 86: ...to scan 000145 CR Interface Type USB OEM 00010D CR Interface Type USB TEC 000147 CR Interface Type USB COM 000135 CR Interface Type USB Keyboard Great care should be taken to select the correct interf...

Страница 87: ...fault settings for other interfaces including Wincor Nixdorf can be found in Appendix D Factory Default Settings 000105 CR Interface Type RS 232 Standard 000112 CR Interface Type RS 232 Wincor Nixdorf...

Страница 88: ...you intend to scan 3 Scan the appropriate digits from the Alpha Numeric Keypad on page 305 that repre sent the desired maximum host transmitted message length The selectable range is 0 249 data charac...

Страница 89: ...o ignore host commands the scanner will ignore all host commands except the minimum set necessary to keep the interface active and transmit labels For normal opera tion of the interface select Obey Ho...

Страница 90: ...gged into the PC Windows will bring up the Found New Hardware message 3 The installation is complete USB Power Compliance This feature enables disables the ability of the Universal Interface to hold o...

Страница 91: ...ils about Keyboard Layout please refer to your operating system manual USB Keyboard Country Mode This feature specifies the country language that will be supported by the keyboard 030200 CR USB Keyboa...

Страница 92: ...board Country Mode Italy 030207 CR USB Keyboard Country Mode Norway 030208 CR USB Keyboard Country Mode Portugal 030209 CR USB Keyboard Country Mode Spain 03020A CR USB Keyboard Country Mode Sweden 03...

Страница 93: ...oard Country Mode Croatia USB Keyboard Country Mode Poland 030213 CR USB Keyboard Country Mode French Canadian 030214 CR 030215 CR USB Keyboard Country Mode Russian USB INTERFACE FEATURES ENTER EXIT P...

Страница 94: ...lts in a Caps Lock OFF functionality To set this feature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan the desired selection from the barcodes below You ll need to cover...

Страница 95: ...n 00H and 1FH Send characters between 00H and 1FH accord ing to special function key mapping table This is used to send keys that are not in normal ASCII set a unique set is provided for each availabl...

Страница 96: ...99 in 10 ms increments A table containing the ASCII Char acter Set and their corresponding decimal values is available in the inside back cover of this manual ASCII parameters must be input by scannin...

Страница 97: ...ming Mode bar code 2 Scan your selection from the bar codes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to...

Страница 98: ...communicate Options are Table Top Scanner Handheld Scanner To set this feature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan your selection from the barcodes below You l...

Страница 99: ...the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you intend to scan Complete the programming sequence by scan...

Страница 100: ...ity with 7 data bits is invalid and will default to 8 data bits and no parity RS 232 Baud Rate 001D04 CR RS 232 Baud Rate 1200 001D03 CR RS 232 Baud Rate 2400 001D02 CR RS 232 Baud Rate 4800 001D01 CR...

Страница 101: ...32 INTERFACE FEATURES ENTER EXIT PROGRAMMING MODE PRODUCT REFERENCE GUIDE 91 RS 232 Baud Rate continued 001D07 CR RS 232 Baud Rate 57600 001D08 CR RS 232 Baud Rate 115200 001D09 CR RS 232 Baud Rate 23...

Страница 102: ...setting of 7 data bits with no parity will default to 8 data bits and no parity 009B00 CR RS 232 Number of Data Bits 7 009B01 CR RS 232 Number of Data Bits 8 RS 232 Number of Stop Bits Specifies numb...

Страница 103: ...ty required for sending and receiving data Options for this setting are RS 232 PARITY NONE RS 232 PARITY EVEN RS 232 PARITY ODD NOTE A setting of no parity with 7 data bits will default to 8 data bits...

Страница 104: ...ive for scanner to read and trans mit data While the CTS line is inactive scanner remains in a host disabled state fol lowing a successful label transmission the CTS signal must transition to inactive...

Страница 105: ...the Enter Exit Programming Mode barcode at the top of the page 2 Scan the barcode below Set RS 232 Intercharacter Delay 3 Scan the appropriate digits from the Alpha Numeric Keypad in Appendix C that r...

Страница 106: ...n the Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that...

Страница 107: ...ex 069D00 CR RS 232 Beep on ASCII BEL Disable 069D01 CR RS 232 Beep on ASCII BEL Enable Beep on Not on File Select for the host to beep or not when a not on file condition is detected by the host 0451...

Страница 108: ...CK NAK when the host sends a command Enable for Label Host Enabled for both Label Transmission Host Command acknowledgement To select the option for RS 232 ACK NAK Enable 1 Scan the Enter Exit Program...

Страница 109: ...cover any unused barcodes on this and the facing page to ensure the scanner reads only the barcode you intend to scan 3 Scan the appropriate digits from the Alpha Numeric Keypad in Appendix C that re...

Страница 110: ...barcodes on this and the facing page to ensure the scanner reads only the barcode you intend to scan 3 Scan the appropriate digits from the Alpha Numeric Keypad in Appendix C that repre sent the hex...

Страница 111: ...REFERENCE GUIDE 101 RS 232 Retry on ACK NAK Timeout This option specifies the action scanner performs on expiration of the RS 232 ACK NAK Tim eout Value 032100 CR RS 232 Retry on ACK NAK Timeout Disa...

Страница 112: ...re that the scanner reads only the barcode you intend to scan 3 Scan the appropriate digits from the Alpha Numeric Keypad in Appendix C that repre sent the desired timeout A setting of 0 specifies an...

Страница 113: ...ed barcodes on this and the facing page to ensure that the scanner reads only the barcode you intend to scan 3 Scan the appropriate digits from the Alpha Numeric Keypad in Appendix C that repre sent t...

Страница 114: ...aracter from the host Errors include unrecognized host commands and communication errors such as parity or framing errors Ignore Errors recommended setting Assume ACK risk of lost label data Assume NA...

Страница 115: ...re 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan the desired option from the barcodes below You ll need to cover any unused barcodes on this and the facing page to ensur...

Страница 116: ...fix on page 108 Global Suffix on page 109 starting on page 110 LABEL ID starting on page 111 Label ID Control on page 111 Setting Label ID on page 112 1D Symbologies Label ID on page 113 2D Symbologie...

Страница 117: ...acters ASCII Label ID Transmission Enable this option to transmit the Label ID you configure for the scanned symbology AIM ID This function is used to identify and display the common label identifier...

Страница 118: ...and their corresponding Hex Values are in the inside back cover of this manual ASCII parameters must be input by scanning a pair of hexadecimal digits for each character To set a two character value...

Страница 119: ...vailable below Contact your dealer for other alternate settings for this feature No Global Suffix CR Carriage Return CR LF Carriage Return Line Feed To set the Global Suffix 1 Scan the Enter Exit Prog...

Страница 120: ...the table below followed by SYMBOLOGY CHAR SYMBOLOGY CHAR SYMBOLOGY CHAR UPC EAN E GS1 Omnidirectional GS1 Expanded e Plessey P Code 39 A Standard 2 of 5 S QR Code and Micro QR Q Codabar F ISBN Xa a I...

Страница 121: ...or Label ID Control 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan the desired option from the barcodes below You ll need to cover any unused barcodes on this and the fac...

Страница 122: ...barcode you intend to scan 3 Scan the appropriate digits from the Alpha Numeric Keypad on page 305 that repre sent the desired Label ID characters entered as two hex pairs A table containing the ASCII...

Страница 123: ...fault Label ID for this symbology is 25 Default Label ID for this symbology is 23 0039 CR Code 128 Label ID 0556 CR Code 128 ISBT Label ID Default Label ID for this symbology is 66 f Default Label ID...

Страница 124: ...D Default Label ID for this symbology is 245A Z Default Label ID for this symbology is 26 0038 CR Code 93 Label ID 0367 CR DataBar Expanded Composite Label ID Default Label ID for this symbology is 52...

Страница 125: ...ult Label ID for this symbology is 50 P 0419 CR EAN 128 Label ID 0031 CR EAN 13 2 Digit Supplemental Label ID Default Label ID for this symbology is 46 F Default Label ID for this symbology is 46 F 00...

Страница 126: ...site Label ID Default Label ID for this symbology is 4646 FF Default Label ID for this symbology is 4F O 0558 CR Follett 2 of 5 Label ID 0561 CR GTIN 2 Digit Supplemental Label ID Default Label ID for...

Страница 127: ...5 CIP HR Label ID 046A CR ISBN Label ID Default Label ID for this symbology is 49 I Default Label ID for this symbology is 6E n 125B CR ISSN Label ID 00BD CR MSI Label ID Default Label ID for this sy...

Страница 128: ...mbology is 41 A 002E CR UPC A 5 Digit Supplemental Label ID 05B3 CR UPCA Composite Label ID Default Label ID for this symbology is 41 A Default Label ID for this symbology is 45 E 002F CR UPC E 2 Digi...

Страница 129: ...l ID for this symbology is 2464 d Default Label ID for this symbology is 4467 Dg GS1 Data Matrix label ID GS1 QR Code label ID Default Label ID for this symbology is 5147 QG Default Label ID for this...

Страница 130: ...EXIT PROGRAMMING MODE 120 MAGELLAN 1500I 2D Symbologies continued PDF 417 Label ID Default Label ID for this symbology is 50 P Default Label ID for this symbology is 5152 QR QR Code Label ID 05A9 CR 0...

Страница 131: ...el ID Kix Label ID Default Label ID for this symbology is 2455 U Default Label ID for this symbology is 244B K Australia Post Label ID Japan Post Label ID Default Label ID for this symbology is 2452 R...

Страница 132: ...eric Keypad in Appendix G that repre sent the desired mid label ID characters entered as two hex pairs A table containing the ASCII Character Set and their corresponding Hex Values is available in the...

Страница 133: ...appended data To set this feature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan barcode for the desired option below You ll need to cover any unused barcodes on this an...

Страница 134: ...ers were converted to the B character and the 1 characters were converted to the numeral 2 character Nothing is done with the last two character pairs since they are all FF To set Character Conversion...

Страница 135: ...upports COUPON CONTROL starting on page 126 starting on page 129 starting on page 134 starting on page 140 starting on page 145 OTHER UPC EAN OPTIONS starting on page 157 starting on page 178 GS1 DATA...

Страница 136: ...ed coupon labels will decode but UPCA coupon labels will not UPCA labels that are not coupon labels and all RSS Databar Expanded labels will decode Priority to UPC A Coupons UPCA coupon labels will be...

Страница 137: ...RODUCT REFERENCE GUIDE 127 Coupon Control Enable continued 03B902 CR Coupon Control Enable GS1 DataBar Expanded Coupons 03B903CR Coupon Control Priority to UPC A Coupons 03B904 CR Coupon Control Prior...

Страница 138: ...r any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you intend to scan 3 Complete the programming sequence by scanning the Enter Exit Programming Mode...

Страница 139: ...Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner...

Страница 140: ...Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the sc...

Страница 141: ...can the Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure tha...

Страница 142: ...ode at the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you int...

Страница 143: ...e barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barco...

Страница 144: ...ogramming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads o...

Страница 145: ...an the Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that...

Страница 146: ...Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the sc...

Страница 147: ...barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode...

Страница 148: ...de at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you...

Страница 149: ...ode barcode at the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode...

Страница 150: ...Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads...

Страница 151: ...Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure th...

Страница 152: ...he Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the...

Страница 153: ...Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner...

Страница 154: ...de at the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you inte...

Страница 155: ...r Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanne...

Страница 156: ...he Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the...

Страница 157: ...ode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar...

Страница 158: ...ode at the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you int...

Страница 159: ...er Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scann...

Страница 160: ...t Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner rea...

Страница 161: ...re 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensu...

Страница 162: ...ing Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only th...

Страница 163: ...Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner...

Страница 164: ...5 characters Default setting for this feature is 08 8 characters 049D05 CR EAN 8 Minimum Segment Length 5 characters 049D06 CR EAN 8 Minimum Segment Length 6 characters 049D07 CR EAN 8 Minimum Segment...

Страница 165: ...E 155 EAN 8 Minimum Segment Length continued 049D0C CR EAN 8 Minimum Segment Length 12 characters 049D0D CR EAN 8 Minimum Segment Length 13 characters 049D0E CR EAN 8 Minimum Segment Length 14 charact...

Страница 166: ...aggressive yet minimizes misreads Moderately Aggressive Even faster scanning even more aggressive Very Aggressive Fastest scan speed most aggressive CAUTION Use caution when setting this feature as m...

Страница 167: ...UPC EAN symbologies In Store Printed Label Minimum Read on page 158 UPC EAN Correlation on page 159 UPC EAN Guard Insertion on page 160 UPC EAN Stitch Exact Label Halves on page 161 UPC EAN Stitch Un...

Страница 168: ...the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you intend to scan 3 Com...

Страница 169: ...ing Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only th...

Страница 170: ...Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads...

Страница 171: ...nter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the sca...

Страница 172: ...rogramming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads...

Страница 173: ...e for the desired setting below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you intend to scan 3 Complete the programming se...

Страница 174: ...imum Segment Length 10 Characters 048F0B CR UPC EAN Minimum Segment Length 11 Characters 048F0C CR UPC EAN Minimum Segment Length 12 Characters 048F0D CR UPC EAN Minimum Segment Length 13 Characters 0...

Страница 175: ...barcode representing the desired option below or on the following pages You ll need to cover any unused barcodes on facing pages to ensure that the scanner reads only the barcode you intend to scan 3...

Страница 176: ...ENTER EXIT PROGRAMMING MODE 166 MAGELLAN 1500I Price Weight Check continued 005C03 CR Price Weight Check 4 digit European price weight 005C04 CR Price Weight Check 5 digit European price weight...

Страница 177: ...p of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you intend to sc...

Страница 178: ...he top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you intend to s...

Страница 179: ...mming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only...

Страница 180: ...d that add ons be included in barcodes NOTE Contact customer support for advanced programming of optional and conditional add ons To set this feature 1 Scan the Enter Exit Programming Mode barcode at...

Страница 181: ...e page 2 Scan the barcode representing the desired option on this and the following page You ll need to cover any unused barcodes on facing pages to ensure that the scanner reads only the barcode you...

Страница 182: ...Read continued 005F07 CR P2 Add on Minimum Read 7 005F08 CR P2 Add on Minimum Read 8 005F09 CR P2 Add on Minimum Read 9 005F0A CR P2 Add on Minimum Read 10 005F0B CR P2 Add on Minimum Read 11 005F0C...

Страница 183: ...OTHER UPC EAN OPTIONS ENTER EXIT PROGRAMMING MODE PRODUCT REFERENCE GUIDE 173 P2 Add on Minimum Read continued 005F0E CR P2 Add on Minimum Read 14 005F0F CR P2 Add on Minimum Read 15...

Страница 184: ...nting the desired option on this and the following page You ll need to cover any unused barcodes on facing pages to ensure that the scanner reads only the barcode you intend to scan 3 Complete the pro...

Страница 185: ...Add on Minimum Read continued 007D07 CR P5 Add on Minimum Read 7 007D08 CR P5 Add on Minimum Read 8 007D09 CR P5 Add on Minimum Read 9 007D0A CR P5 Add on Minimum Read 10 007D0B CR P5 Add on Minimum...

Страница 186: ...ENTER EXIT PROGRAMMING MODE 176 MAGELLAN 1500I P5 Add on Minimum Read continued 007D0E CR P5 Add on Minimum Read 14 007D0F CR P5 Add on Minimum Read 15...

Страница 187: ...osites for EAN13 If clear disables Composites for EAN13 To set this feature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan the barcode below You ll need to cover any unus...

Страница 188: ...formation will be appended to the converted GTIN barcode To set this feature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You...

Страница 189: ...e added feature is a factory programmed option Con tact your dealer for information about upgrading your system to include this advanced capability To set this feature 1 Scan the Enter Exit Programmin...

Страница 190: ...barcode at the top of the page 3 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode...

Страница 191: ...scarded To set this feature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and th...

Страница 192: ...the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you intend to scan 3 Comp...

Страница 193: ...on from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you intend to scan Complete the programming sequence...

Страница 194: ...it Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner re...

Страница 195: ...code at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode yo...

Страница 196: ...Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner read...

Страница 197: ...ng Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the...

Страница 198: ...ystem to include this advanced capability To set this feature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cov...

Страница 199: ...barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcod...

Страница 200: ...is feature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to...

Страница 201: ...rcode at the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you i...

Страница 202: ...de barcode at the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode...

Страница 203: ...panded Length 1 on page 193 below You ll need to cover any unused barcodes on this and the facing page to ensure that the scanner reads only the barcode you intend to scan 3 Scan the appropriate digit...

Страница 204: ...2 Scan the barcode Set DataBar Expanded Length 2 on page 194 below You ll need to cover any unused barcodes on this and the facing page to ensure that the scanner reads only the barcode you intend to...

Страница 205: ...ed Stacked labels that have the last row incorrectly printed in reverse will not be read To set this feature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan your selection...

Страница 206: ...rogramming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads...

Страница 207: ...Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure t...

Страница 208: ...t a mis read can occur To set this feature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar c...

Страница 209: ...1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure...

Страница 210: ...mming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only...

Страница 211: ...de barcode at the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode...

Страница 212: ...ing Mode barcode at the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the ba...

Страница 213: ...the barcode Set Code 39 Length 1 on page 203 below You ll need to cover any unused barcodes on this and the facing page to ensure that the scanner reads only the barcode you intend to scan 3 Scan the...

Страница 214: ...op of the page 2 Scan the barcode Set Code 39 Length 2 on page 204 below You ll need to cover any unused barcodes on this and the facing page to ensure that the scanner reads only the barcode you inte...

Страница 215: ...e decoded if all barcode proofing requirements are met To set this feature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan your selection from the barcodes below You ll ne...

Страница 216: ...t the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you inte...

Страница 217: ...Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure t...

Страница 218: ...the Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that th...

Страница 219: ...ature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to e...

Страница 220: ...rogramming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads...

Страница 221: ...an the Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that...

Страница 222: ...at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you in...

Страница 223: ...e barcode at the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode y...

Страница 224: ...ing Mode barcode at the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the ba...

Страница 225: ...the barcode Set Code 128 Length 1 on page 215 below You ll need to cover any unused barcodes on this and the facing page to ensure that the scanner reads only the barcode you intend to scan 3 Scan th...

Страница 226: ...e barcode at the top of the page 2 Scan the barcode Set Code 128 Length 2 on page 216 below You ll need to cover any unused barcodes on this and the facing page to ensure that the scanner reads only t...

Страница 227: ...be decoded if all barcode proofing requirements are met To set this feature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan your selection from the barcodes below You ll n...

Страница 228: ...t the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you inte...

Страница 229: ...To set this feature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the fa...

Страница 230: ...ode are treated as data characters 1 To set this feature 2 Scan the Enter Exit Programming Mode barcode at the top of the page 3 Scan either the enable or disable barcode below You ll need to cover an...

Страница 231: ...ed feature Full Label Edit is enabled To set this feature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover a...

Страница 232: ...at the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you intend...

Страница 233: ...Enter Exit Programming Mode barcode at the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanne...

Страница 234: ...I 2 of 5 Length 1 on page 224 below You ll need to cover any unused barcodes on this and the facing page to ensure that the scanner reads only the barcode you intend to scan 3 Scan the appropriate dig...

Страница 235: ...ing Mode barcode at the top of the page 2 Scan the barcode Set I 2 of 5 Length 2 on page 225 below You ll need to cover any unused barcodes on this and the facing page to ensure that the scanner reads...

Страница 236: ...rogramming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads...

Страница 237: ...Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure t...

Страница 238: ...e barcode below or from the following page representing the desired option You ll need to cover any unused barcodes and facing pages to ensure that the scanner reads only the barcode you intend to sca...

Страница 239: ...ng Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the...

Страница 240: ...re treated as data characters To set this feature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unuse...

Страница 241: ...dit is enabled To set this feature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on...

Страница 242: ...e at the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you inten...

Страница 243: ...Programming Mode barcode at the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads on...

Страница 244: ...de Set Codabar Length 1 on page 234 below You ll need to cover any unused barcodes on this and the facing page to ensure that the scanner reads only the barcode you intend to scan 3 Scan the appropria...

Страница 245: ...at the top of the page 2 Scan the barcode Set Codabar Length 2 on page 235 below You ll need to cover any unused barcodes on this and the facing page to ensure that the scanner reads only the barcode...

Страница 246: ...t the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you inte...

Страница 247: ...r Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanne...

Страница 248: ...e at the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you inten...

Страница 249: ...Programming Mode barcode at the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads on...

Страница 250: ...de Set Code 93 Length 1 on page 240 below You ll need to cover any unused barcodes on this and the facing page to ensure that the scanner reads only the barcode you intend to scan 3 Scan the appropria...

Страница 251: ...ode at the top of the page 2 Scan the barcode Set Code 93 Length 2 on page 241 below You ll need to cover any unused barcodes on this and the facing page to ensure that the scanner reads only the barc...

Страница 252: ...gramming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads on...

Страница 253: ...code are treated as data characters To set this feature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any...

Страница 254: ...de at the top of the page 2 Scan the barcode below representing the desired number of MSI check characters to be calculated and verified You ll need to cover any unused barcodes on this and the facing...

Страница 255: ...Label Edit is enabled To set this feature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar c...

Страница 256: ...rcode at the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you i...

Страница 257: ...rogramming Mode barcode at the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only...

Страница 258: ...Set MSI Length 1 on page 248 below You ll need to cover any unused barcodes on this and the facing page to ensure that the scanner reads only the barcode you intend to scan 3 Scan the appropriate digi...

Страница 259: ...op of the page 2 Scan the barcode Set MSI Length 2 on page 249 below You ll need to cover any unused barcodes on this and the facing page to ensure that the scanner reads only the barcode you intend t...

Страница 260: ...it Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner re...

Страница 261: ...n a barcode is treated as data character To set this feature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cove...

Страница 262: ...Label Edit is enabled To set this feature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar c...

Страница 263: ...arcode at the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you...

Страница 264: ...at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you in...

Страница 265: ...Exit Programming Mode barcode at the top of the page 2 Scan your selection from the barcodes below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner read...

Страница 266: ...the barcode Set Standard 2 of 5 Length 1 on page 256 below You ll need to cover any unused barcodes on this and the facing page to ensure that the scanner reads only the barcode you intend to scan 3 S...

Страница 267: ...Exit Programming Mode barcode at the top of the page 2 Scan the barcode Set Standard 2 of 5 Length 2 on page 257 below You ll need to cover any unused barcodes on this and the facing page to ensure th...

Страница 268: ...rning the various 2D and Postal Code barcode types the scanner supports SECTION CONTENTS 2D Codes DATA MATRIX starting on page 259 PDF 417 starting on page 263 MICRO PDF 417 starting on page 267 QR CO...

Страница 269: ...Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the sc...

Страница 270: ...t fixed length using the Data Matrix Length 1 Length 2 Program ming Instructions on page 261 that follow this page 5 Set Length 2 to the second fixed length or to 0000 if there is only one fixed lengt...

Страница 271: ...he page 2 Scan the barcode Set Data Matrix Length 1 on page 261or Set Data Matrix Length 2 on page 261 below You ll need to cover any unused barcodes on this and the facing page to ensure that the sca...

Страница 272: ...mming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only...

Страница 273: ...ming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only t...

Страница 274: ...o the first fixed length using the PDF 417 Length 1 Length 2 Program ming Instructions on page 265 that follow this page 5 Set Length 2 to the second fixed length or to 0000 if there is only one fixed...

Страница 275: ...ata characters only Any value 2710 will be considered to be 2710 To set this feature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan the barcode Set PDF 417 Length 1 on pa...

Страница 276: ...de at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you...

Страница 277: ...e Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the...

Страница 278: ...ed length using the Micro PDF 417 Length 1 Length 2 Pro gramming Instructions on page 269 that follow this page 5 Set Length 2 to the second fixed length or to 0000 if there is only one fixed length u...

Страница 279: ...e s data characters only Any value 0366 will be considered to be 0366 To set this feature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan the barcode Set Micro PDF 417 Len...

Страница 280: ...e barcode below for the desired setting You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the barcode you intend to scan 3 Complete the progra...

Страница 281: ...r Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanne...

Страница 282: ...o the first fixed length using the QR Code Length 1 Length 2 Program ming Instructions on page 273 that follow this page 5 Set Length 2 to the second fixed length or to 0000 if there is only one fixed...

Страница 283: ...10 will be considered to be 2710 To set this feature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan the barcode Set QR Code Length 1 on page 273 or Set QR Code Length 2 o...

Страница 284: ...g Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the...

Страница 285: ...Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the sc...

Страница 286: ...Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner read...

Страница 287: ...e first fixed length using the Micro QR Code Length 1 Length 2 Pro gramming Instructions on page 278 that follow this page 5 Set Length 2 to the second fixed length or to 0000 if there is only one fix...

Страница 288: ...ll be considered to be 3700 To set this feature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan the barcode Set Aztec Length 1 on page 281 or Set Micro QR Code Length 2 on...

Страница 289: ...nter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the sca...

Страница 290: ...th 1 to the first fixed length using the Aztec Length 1 Length 2 Programming Instructions on page 281 that follow this page 5 Set Length 2 to the second fixed length or to 0000 if there is only one fi...

Страница 291: ...3700 will be considered to be 3700 To set this feature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan the barcode Set Aztec Length 1 on page 281 or Set Aztec Length 2 on...

Страница 292: ...ramming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads onl...

Страница 293: ...o decode Postnet labels To set this feature 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar...

Страница 294: ...Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner read...

Страница 295: ...nter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the sca...

Страница 296: ...gramming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads on...

Страница 297: ...the Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that th...

Страница 298: ...Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads...

Страница 299: ...it Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner re...

Страница 300: ...Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner read...

Страница 301: ...e Enter Exit Programming Mode barcode at the top of the page 2 Scan either the enable or disable barcode below You ll need to cover any unused bar codes on this and the facing page to ensure that the...

Страница 302: ...IM ID Label ID Label ID Bar Code Data 00 20 Characters ASCII AND OR OR Example Setting a Prefix In this example we ll set a prefix for all symbologies 1 Determine which ASCII character s are to be add...

Страница 303: ...ustom Label IDs individually per symbology If you wish to program the scanner to always include an industry standard label identifier for ALL symbology types see the feature AIM ID on page 110 The Lab...

Страница 304: ...ISH PPT Y 245900 CODE39 LAPOSTE Y 245900 CODE39 PZN Z 245A00 CODE93 260000 DATABAR 14 R4 523400 DATABAR 14 COMPOSITE R4 523400 DATABAR EXPANDED RX 525800 DATABAR EXPANDED COMPOSITE RX 525800 DATABAR L...

Страница 305: ...6E0000 MICRO QR Q 245100 MICRO PDF mP 6D5000 MSI 400000 PDF417 P 500000 PLESSEY a 610000 POSTAL AUSTRALIAN K 244B00 POSTAL IMB V 245600 POSTAL JAPANESE R 245200 POSTAL KIX U 245500 POSTAL PLANET W 245...

Страница 306: ...LABEL ID 296 MAGELLAN 1500I UPCA P2 A 410000 UPCA P5 A 410000 UPCA COMPOSITE A 410000 UPCE E 450000 UPCE P2 E 450000 UPCE P5 E 450000 UPCE COMPOSITE E 450000 Symbology Default Character Default ASCII...

Страница 307: ...owing the Length 1 Length 2 Programming Instructions below Configuring Variable Length Decoding 1 Scan the Enter Exit Programming Mode barcode at the top of the page 2 Scan the Variable Length Decodin...

Страница 308: ...es GS1 Databar Expanded Stacked GS1 Databar Stacked GS1 Databar Stacked Omnidirectional Micro PDF417 PDF417 Postal Codes Australian Post British Post Canadian Post China Post IMB Japanese Post KIX Pos...

Страница 309: ...Parameter Specification Interfaces USB Keyboard USB COM OEM IBM USB RS 232 OPTIONAL FEATURES PHYSICAL CHARACTERISTICS Parameter Specification Colors Black White Dimensions Unit plus Tilting Stand 6 1...

Страница 310: ...Contrast and Ambient Light Dependent 1D Linear Codes 5 mils 2 5 to 9 0 cm 0 9 to 3 5 in 7 5 mils 0 to 17 0 cm 0 to 6 6 in 10 mils 0 to to 21 cm 0 to 8 2 in 13 mils UPC 0 to 25 0 cm 0 to 9 8 in 20 mils...

Страница 311: ...r can be used for scanner configuration It is avail able for download at no charge OPOS JavaPOS JavaPOS Utilities and OPOS Utilities are available for down load at no charge Remote Host Download Lower...

Страница 312: ...nd may be programmed to behave differently Host Disable Constant green flash at 1 Hz 100mS on 900mS off The scanner is disabled due to receiving a disable com mand from the POS terminal Diagnostics Va...

Страница 313: ...configured to do so the scanner will sound a series of beeps correspond ing to the error code and or flash its LED simultaneous to the beeps The table below describes what these codes mean and what a...

Страница 314: ...304 MAGELLAN 1500I APPENDIX B CABLE PINOUTS STANDARD CABLE PINOUTS PRIMARY INTERFACE CABLES Pin RS 232 USB USB Keyboard USB COM USB OEM 1 D 2 CTS 3 D 4 RTS 5 RxD 6 TxD 7 ERI 8 Vin VBUS 9 GND GND...

Страница 315: ...PRODUCT REFERENCE GUIDE 305 APPENDIX C ALPHA NUMERIC KEYPAD A B C D E F...

Страница 316: ...306 MAGELLAN 1500I 1 2 3 4 5 6 7 8 NOTE For numeric entry sequences the scanner will announce the number of digits remaining to be entered after each label read...

Страница 317: ...PRODUCT REFERENCE GUIDE 307 9 0...

Страница 318: ...8 400ms 28 400ms 28 400ms 28 400ms 28 400ms 28 400ms 2D Double Read Timeout 46 700ms 46 700ms 46 700ms 46 700ms 46 700ms 46 700ms Double Read Table Size 7 entries 7 entries 7 entries 7 entries 7 entri...

Страница 319: ...ERI Timeout 02 20 mS 02 20 mS 02 20 mS 02 20 mS 02 20 mS 02 20 mS Good Read LED Idle State 02 on dim 02 on dim 02 on dim 02 on dim 02 on dim 02 on dim Scanner Control Button Options 01 01 01 01 01 01...

Страница 320: ...Com pres sion 100 64 Com pres sion 100 64 Com pres sion 100 64 Com pres sion 100 64 Com pression 100 Region of Interest ROI 000004FF0 00003FF full size 000004F F000003 FF full size 000004F F000003 FF...

Страница 321: ...pon enumera tion 00 dis abled upon enumera tion RS 232 Baud Rate 01 9600 01 9600 01 9600 01 9600 RS 232 Number of Data Bits 01 8 data bits 01 8 data bits 01 8 data bits 01 8 data bits RS 232 Number of...

Страница 322: ...te Transmission Failure 01 enable 01 enable 01 enable 01 enable Data Editing Global Prefix 00 no prefix 00 no prefix 00 no prefix 00 no prefix 00 no prefix 00 no prefix Global Suffix 0D00 CR 0D00 CR 0...

Страница 323: ...able 01 enable 01 enable 01 enable 01 enable 01 enable UPC A Minimum Read 01 1 read 01 1 read 01 1 read 01 1 read 01 1 read 01 1 read Expand UPC A to EAN 13 00 dis able 00 dis able 01 enable 00 dis ab...

Страница 324: ...e 00 disable EAN 8 Jan 8 Both Guards Sub stitution 00 dis able 00 dis able 00 dis able 00 dis able 00 dis able 00 disable EAN 8 Stitch Exact Label Halves 00 dis able 00 dis able 00 dis able 00 dis abl...

Страница 325: ...1 1 read 01 1 read 01 1 read 01 1 read 01 1 read UPC EAN Composites 00 dis able 00 dis able 00 dis able 00 dis able 00 dis able 00 disable GTIN 00 dis able 00 dis able 00 dis able 00 dis able 00 dis a...

Страница 326: ...01 01 01 01 DataBar Expanded Length 2 4A 4A 4A 4A 4A 4A DataBar Expanded Reverse Retry 00 dis able 00 dis able 00 dis able 00 dis able 00 dis able 00 disable Code 39 01 enable 01 enable 01 enable 01 e...

Страница 327: ...e 00 dis able 00 dis able 00 dis able 00 disable Code 128 Minimum Read 01 1 read 01 1 read 01 1 read 01 1 read 01 1 read 01 1 read Code 128 Length Control 00 variable 00 vari able 00 vari able 00 vari...

Страница 328: ...enable 01 enable 01 enable 01 enable 01 enable 01 enable Codabar Minimum Read 01 1 read 01 1 read 01 1 read 01 1 read 01 1 read 01 1 read Codabar Length Control 00 dis able 00 dis able 00 dis able 00...

Страница 329: ...able 00 dis able 00 dis able 00 dis able 00 disable Standard 2 of 5 Check Character Calculation 00 dis able 00 dis able 00 dis able 00 dis able 00 dis able 00 disable Standard 2 of 5 Check Character...

Страница 330: ...7 Length 2 0A96 0A96 0A96 0A96 0A96 0A96 PDF 417 Read Option 00 none 00 none 00 none 00 none 00 none 00 none Micro PDF 417 00 dis able 00 dis able 00 dis able 00 dis able 00 dis able 00 disable Micro...

Страница 331: ...2 0E74 0E74 0E74 0E74 0E74 0E74 Aztec Code 00 dis able 00 dis able 00 dis able 00 dis able 00 dis able 00 disable Aztec Length Control 00 variable 00 vari able 00 vari able 00 vari able 00 vari able 0...

Страница 332: ...e 00 dis able 00 dis able 00 dis able 00 dis able 00 disable Sweden Post 00 dis able 00 dis able 00 dis able 00 dis able 00 dis able 00 disable Portugal Post 00 dis able 00 dis able 00 dis able 00 dis...

Страница 333: ...keypad 00h 4Bh 10 DLE PAGE DOWN inner keypad 00h 4Eh 11 DC1 HOME inner keypad 00h 4Ah 12 DC2 LEFT arrow inner keypad 00h 50h 13 DC3 DOWN arrow inner keypad 00h 51h 14 DC4 UP arrow inner keypad 00h 52h...

Страница 334: ...d 48h E0 324 MAGELLAN 1500I Scanset 1 Function Key Map Scanset 2 Function Key Map ASCII hex ASCII code Key Scancode 02 STX ALT left Make 11h 03 ETX ALT left Break F0h 11h 04 EOT CTRL left Make 14h 05...

Страница 335: ...h 58h 08 BS BS 66h 09 HT TAB right 0Dh 0A LF RIGHT arrow inner keypad 6Ah 0B VT TAB left 0Dh S 0C FF Enter inner keypad 79h 0D CR CR 5Ah 0E SO INSERT inner keypad 67h 0F SI PAGE UP inner keypad 6Fh 10...

Страница 336: ...eypad 6Ah 0B VT TAB left 0Dh S 0C FF CR FIELD EXIT Make only 5Ah F0h 5Ah 0D CR CR FIELD EXIT Make Break 5Ah 0E SO INSERT inner keypad 65h 0F SI FIELD 79h 10 DLE FIELD 7Ch 11 DC1 HOME inner keypad 62h...

Страница 337: ...h FF Enter right keypad 60h 0Dh CR CR 3Bh 0Eh SO INSERT inner keypad 52h 0Fh SI PAGE UP inner keypad 49h 10h DLE PAGE DOWN inner keypad 51h 11h DC1 HOME inner keypad 4Ch 12h DC2 LEFT arrow inner keypa...

Страница 338: ...ight 0Fh 0Ah LF RIGHT arrow inner keypad 3Ch 0Bh VT TAB left 0Fh S 0Ch FF DELETE 39h 0Dh CR CR 1Ch 0Eh SO INSERT inner keypad 38h 0Fh SI KATAKANA LOCK ON Make 72h 10h DLE KATAKANA LOCK OFF Break F2h 1...

Страница 339: ...gardless of beep set ting Identification request i 0x69 Returns long responsea a Call Tech Support for information Health request h 0x68 Returns long responsea Status request s 0x73 Returns long respo...

Страница 340: ...0 MAGELLAN 1500I APPENDIX G SAMPLE SYMBOLS 1D SYMBOL SAMPLES 0 1234567890 UPC A 0 5 1234567890 Interleaved 2 of 5 Code 128 Code 128 9 780330 290951 EAN 13 BC321 Code 39 A13579B Codabar 123456 9 Code 9...

Страница 341: ...PRODUCT REFERENCE GUIDE 331 0100123456789050 GS1 DataBar Expanded 01 00123456789012 GS1 DataBar Omnidirectional 123456 Code 2 of 5 01 16543210987654 GS1 DataBar Limited...

Страница 342: ...2D SAMPLE SYMBOLS 332 MAGELLAN 1500I 2D SAMPLE SYMBOLS A12B3C BV17453 1314H17LL PDF 417 Micro PDF 417 Datamatrix QR Code 35900G9 Micro QR Code Aztec This is an Aztec Code ABCDEF...

Страница 343: ...PRODUCT REFERENCE GUIDE 333 COMPOSITE SAMPLE SYMBOLS GS1 DataBar Limited Composite GS1 DataBar Truncated Composite...

Страница 344: ...COMPOSITE SAMPLE SYMBOLS 334 MAGELLAN 1500I NOTES...

Страница 345: ...2 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F SP 0 1 2 3 4 5 6 7 8 9 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F A B C D E F G H I J K L M N O P Q R S T...

Страница 346: ...ght no part of this documentation may be repro duced stored in or introduced into a retrieval system or transmitted in any form or by any means or for any purpose without the express written permissio...

Отзывы: