GWY-01-PBS-01
78
5
Next, the Master signals that this fragment is ready, by toggling
Bit 1
of the
OBCB
&
OBDCB
. Since this
is
the final fragment, the Master clears
Bit 3
to 0.
(See the
Green
changes below)
Output Buffer
Input Buffer
Byte # Value
Byte # Value
00:
82
Output Buffer Control Byte
(OBCB)
7 6 5 4 3 2 1 0
[1] [0] [0] [0]
[0]
[0]
[1]
[0]
00
80
Input Buffer Control Byte
(IBCB)
7 6 5 4 3 2 1 0
[1] [0] [0] [0] [0] [0] [0] [0]
01: 00 (Always
0)
01: 00
02:
06
(Packet length in bytes)
02:
00
03:
04:
05:
06:
07:
08:
09:
10:
11:
12:
13:
14:
15:
16:
17:
18:
19:
20:
21:
22:
23:
24:
25:
26:
27:
28:
29:
30:
85
86
87
88
89
90
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
(CBx Command Data Byte 45)
(CBx Command Data Byte 46)
(CBx Command Data Byte 47)
(CBx Command Data Byte 48)
(CBx Command Data Byte 49)
(CBx Command Data Byte 50)
03:
04:
05:
06:
07:
08:
09:
10:
11:
12:
13:
14:
15:
16:
17:
18:
19:
20:
..
30:
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
..
00
31:
82
Data Consistency Byte (OBDCB)
31: 80
Data Consistency Byte (IBDCB)