GWY-01-PBS-01
12
1
The Dashboard should send some commands to retrieve device and configuration
information from the device. If serial communications are set up correctly, the device
configuration area within the Cobalt Dashboard should now look like this:
Figure 12: Cobalt Dashboard™ Gateway Profibus Device Configuration Area
The default Profibus ID is 63, and the default Input and Output Buffer sizes are 64 bytes
each.
To change the Profibus ID of the device, and/or the Input Buffer/Output Buffer sizes, enter
the desired values in the appropriate boxes in the configuration tab, and click “Set Config”.
For Profibus, the new ID and buffer sizes will not take effect until the device is reset one
more time, or the power is cycled. Turn the unit off and back on to use the new ID and buffer
size settings. For other settings (such as Tag Type, continuous read parameters, etc), the
unit does not need to be reset again or have the power cycled.
See the Cobalt Dashboard™ User's Manual for more configuration details.