Enter/Exit Programming Mode
104
DSM0400 Fixed Mount Area Imager Bar Code Reader
Code 128 Set Length 1
Specifies one of the barcode lengths for Code 128. Length 1 is the minimum
label length if in
Mode, or the first fixed length if in
Mode. Length includes the barcode’s data characters
only. The length can be set from 1 to 80 characters. For more detailed pro-
gramming instructions, see "Set Length" on
.
provides some examples for setting Length 1.
Table 3. Code 128 Length 1 Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
01 Character
07 Characters
15 Characters
80 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODE 128 LENGTH 1 SETTING
4
Scan Two Characters From
‘0’ and ‘1’
‘0’ and ‘7’
‘1’ and ‘5’
‘8’ and ‘0’
5
Scan ENTER/EXIT PROGRAMMING MODE
Select Code 128 Set Length 1 Setting
Make a mistake? Scan the CANCEL barcode to abort and
not save the entry string. You can then start again at the
beginning.
CANCEL
DEFAULT
01 = Length 1 is 1 Character
Содержание DSM0400
Страница 1: ...DSM0400 Product Reference Guide Fixed Mount Area Imager Bar Code Reader ...
Страница 12: ...Introduction 4 DSM0400 Fixed Mount Area Imager Bar Code Reader NOTES ...
Страница 30: ...22 DSM0400 Fixed Mount Area Imager Bar Code Reader NOTES ...
Страница 220: ...212 DSM0400 Fixed Mount Area Imager Bar Code Reader NOTES ...
Страница 237: ...DSM0400 Dimensions Product Reference Guide 229 DSM0400 Dimensions ...
Страница 238: ...Technical Specifications 230 DSM0400 Fixed Mount Area Imager Bar Code Reader Multi face Bracket for Mounting in 5 sides ...
Страница 239: ...DSM0400 Dimensions Product Reference Guide 231 Angular Mounting Bracket 17 to 25 Possible Angle ...
Страница 242: ...Technical Specifications 234 DSM0400 Fixed Mount Area Imager Bar Code Reader NOTES ...
Страница 248: ...Sample Bar Codes 240 DSM0400 Fixed Mount Area Imager Bar Code Reader NOTES ...
Страница 250: ...Keypad 242 DSM0400 Fixed Mount Area Imager Bar Code Reader 6 7 8 9 ...