RAPID CONFIGURATION
7
1
Auto Setup (Optional)
At the end of the
Auto Learn
procedure, you have the possibility to follow the
Auto Setup
procedure to set up the reading parameters.
1. Enter the
Auto Setup
function by holding the X-PRESS™ push button pressed until the
SETUP LED is on.
2. Release the button to enter the
Auto Setup
function.
3. Once entered, if a barcode label is positioned in front of the scanline, the scanner
automatically performs the optimal setup of the reading parameters for that specific
barcode.
green
green
yellow
yellow
red
SETUP
LEARN
TEST
READY
GOOD
TRIGGER
COM
STATUS
Figure 7 – X-PRESS™ Interface: Auto Setup Function
The procedure is as follows:
A)
place
the desired barcode on
the scanline.
B)
enter
the AutoSetup function
(the laser turns on and the
SETUP LED blinks to indicate
the ongoing process)
C)
wait
until the SETUP LED stays
steady on (indicating the reader
has detected the barcode)
This procedure ends either when the barcode is successfully decoded or after a timeout of
about 7 (seven) seconds.
The scanner will restart at the end of the process, and then the optimized reading
parameters for that barcode are automatically configured in scanner memory.
NOTE
If your application has been configured using X-PRESS™, go to STEP 5.
Reset Scanner to Factory Default (Optional)
If it ever becomes necessary to reset the scanner to the factory default values, you can
perform this procedure by holding the X-PRESS™ push button pressed while powering up
the scanner. At the end of the procedure (about 5-6 seconds), the Configuration and
Environmental parameters are reset, and all LEDs blink simultaneously 3 times. If connected
through a CBX500 with display module, the message "Default Set" is shown on the display.
Содержание DS2100N
Страница 1: ...DS2100N Reference Manual ...
Страница 20: ...DS2100N REFERENCE MANUAL 10 1 b Operating mode selection and definition c Digital Outputs configuration ...
Страница 54: ...DS2100N REFERENCE MANUAL 44 4 Figure 46 ID NET Network Connections with isolated power blocks ...
Страница 55: ...CBX ELECTRICAL CONNECTIONS 45 4 Figure 47 ID NET Network Connections with Common Power Branch Network ...
Страница 56: ...DS2100N REFERENCE MANUAL 46 4 Figure 48 ID NET Network Connections with Common Power Star Network ...
Страница 69: ...25 PIN CABLE ELECTRICAL CONNECTIONS 59 5 Figure 68 DS2100N Multidrop Connection to a Multiplexer ...
Страница 72: ...DS2100N REFERENCE MANUAL 62 5 Figure 70 ID NET Network Connections with isolated power blocks ...
Страница 73: ...25 PIN CABLE ELECTRICAL CONNECTIONS 63 5 Figure 71 ID NET Network Connections with Common Power Branch Network ...
Страница 74: ...DS2100N REFERENCE MANUAL 64 5 Figure 72 ID NET Network Connections with Common Power Star Network ...
Страница 119: ...www datalogic com ...